background image

Section Header

12

12V

1.  

Day Indicator - Displays the day of the week.

2.  

Mesh Symbol - Displayed when connected to the neoHub.

3.  

Floor Limit Symbol - Displayed when the floor probe has reached the 
temperature limit set on feature 07.

4.  

Frost Symbol - Displayed when frost protection mode is active.

5.  

Flame Symbol - Displayed when the thermostat is calling for heat, flashes when 
optimum start is active.

6.  

Floor/Room Temp - Indicates the current sensor mode.

7.  

Set - Displayed when changes are being made to the program schedule or 
current set point.

8.  

Key Lock Indicator - Displayed when the KeyLock is Locked.

9  

Program Indicator - Displayed during programming to show which period is 
being altered.

10.   Main Menu - Displays which option is currently selected.
11.   Temperature Format - Degrees Celsius or Fahrenheit.
12.   Temperature - Displays the current sensor temperature.
13.   Clock - Time displayed in 24 hour format.
14.   Holiday Left - Displayed when the thermostat is in holiday mode.
15.   Hold Left - Displayed when a temperature hold is active, the remaining time  

will be shown.

LCD Display

Содержание neoStat

Страница 1: ...12V...

Страница 2: ...2 Series Model 12V Available in Sapphire Black and Glacier White...

Страница 3: ...itching Times Timer Override Optional Features Optional Features Table Notes Mode 2 Time Clock LCD Display Temperature Display Setting the Clock Setting the Comfort Levels Setting the Temperature Temp...

Страница 4: ...times you want the heating to be on and what temperature it should reach while it is on It will allow you to select different temperatures in your home at different times of the day and days of the w...

Страница 5: ...with the temperature You won t have to adjust the thermostat further Any adjustment above this setting will waste energy and cost you more money You are able to temporarily adjust the heating program...

Страница 6: ...t front somewhere safe Terminate the thermostat as shown in the diagrams on pages 28 29 of this booklet Step 3 Screw the thermostat back plate securely into the back box Step 4 Clip the front of the t...

Страница 7: ...Section Header 6 12V 1 2 3 4...

Страница 8: ...t keys to scroll to SETUP Press and hold the Tick button for 10 seconds Use the Left Right keys to scroll between modes Mode 1 Thermostat Mode 2 Time Clock Note the selected option will flash Press th...

Страница 9: ...neoHub Connect the neoHub to your router with the Ethernet cable provided The router will automatically assign an IP address to the neoHub the Link LED will light up once the neoHub has connected to y...

Страница 10: ...RF thermostats The Mesh symbol is shown when the device is communicating with the neoHub if the mesh symbol disappears this indicates connection to the neoHub has been lost Press the Tick key to pair...

Страница 11: ...Section Header 10 12V 12V 10 Mode 1 Thermostat 12V...

Страница 12: ...11 Series Section Header 2 3 1 4 6 7 8 5 15 14 12 11 9 10 13...

Страница 13: ...rent sensor mode 7 Set Displayed when changes are being made to the program schedule or current set point 8 Key Lock Indicator Displayed when the KeyLock is Locked 9 Program Indicator Displayed during...

Страница 14: ...eing used by showing either Room Temp or Floor Temp before the actual temperature value When the neoStat is set to use both the air the floor sensor the room temperature will be displayed by default T...

Страница 15: ...l to CLOCK Press Tick to confirm selection Use the Up Down keys to set the hours 24 hour format Press Tick to confirm selection Use Up Down keys to set the minutes Press Tick to confirm selection Use...

Страница 16: ...ake 09 00 16 C Leave 16 00 21 C Return 22 00 16 C Sleep If you only want to use 2 levels you should program the unused levels to For Weekday Weekend programming the four comfort levels are the same fo...

Страница 17: ...firm Use the Up Down keys to set the temperature Press Tick to confirm the settings Press the right arrow key LEAVE will now flash and the current settings will be displayed Press Tick to alter LEAVE...

Страница 18: ...see the word SET and the desired temperature value Use the Up Down keys to adjust the SET value Press Tick to confirm settings and return to the main display Note This new temperature is maintained o...

Страница 19: ...selection Use the Up Down keys to set the desired Hold period Press Tick to confirm selection Use the Up Down keys to set the desired Hold temperature Press Tick to confirm selection You will see the...

Страница 20: ...he neoStat will display the frost icon and will only turn the heating ON should the room temperature drop below the set frost temperature see page 23 If the heating is turned ON whilst in frost mode t...

Страница 21: ...e neoStat will display the frost icon and will only turn the heating ON should the room temperature drop below the set frost temperature see page 23 If the heating is turned ON whilst in frost mode th...

Страница 22: ...or heating to achieve the set temperature but the neoStat remains active To turn the neoStat off completely scroll to the Power Icon and hold the Tick key for approximately 4 seconds until the display...

Страница 23: ...ill then automatically return to the program mode on your return Use the Left Right keys to scroll to HOLIDAY and press Tick Using the Up Down keys enter the number of days holiday Press Tick to confi...

Страница 24: ...he thermostat is in Frost Mode The range is 07 17 C The default is 12 C and is suitable for most applications Feature 04 Output Delay To prevent rapid switching an output delay can be entered This can...

Страница 25: ...f change of 20 the thermostat has calculated the heating needs 20 minutes to raise the building temperature 1 C and starts the heating accordingly Feature 09 Rate of Change Number of minutes for 1 C t...

Страница 26: ...l Settings Use the Left Right keys to select SETUP Press Tick to confirm selection Use the Up Down keys to scroll through features Use the Left Right keys to adjust the setting within each feature Pre...

Страница 27: ...on this model Program Mode Temperature Format DESCRIPTION Used to add zone to the neoHub 00 0 5 C 01 1 0 C Default 02 2 0 C 03 3 0 C 07 17 C 12 C Default 00 15 Minutes 00 Default 00 10 C 00 Default 00...

Страница 28: ...new temperature value Press the Tick key to confirm the change and the display will go blank Press the Tick key once to turn the thermostat ON Error Codes E0 The internal sensor has developed a fault...

Страница 29: ...1 A2 A1 Floor Sensor 12VDC CH Remote Air Sensor UH1 ZONE X A2 A1 B Y _ ZONE X A2 A1 B Y _ Connecting neoStat to the UH1 The UH1 allows connection of up to eight 12 volt neo thermostats When connecting...

Страница 30: ...hing With the Heatmiser PRC A2 B2 NO NC C NO NC C N E L 230V SUPPLY IN Volt Free Output POWERED RELAY CARD _ Recommendations Max Cable Size 1 5MM Back Box Depth 35MM Max Load 3 Amps For 230V switched...

Страница 31: ...econds then the display will show option 1 or 2 Use the Left Right keys to scroll between modes selection will flash Mode 1 Thermostat Mode 2 Time Clock Press the Tick key to confirm selection The the...

Страница 32: ...31 Series Section Header 1 4 5 2 10 7 9 3 8 Series 31 6 Mode 2 Time Clock Series...

Страница 33: ...hedule or current set point 5 Program Indicator Displayed during programming to show which period is being altered 6 Main Menu Displays which option is currently selected 7 Timer Status Displays the c...

Страница 34: ...ing time and press the Tick key Use the Up Down keys to select the ON time HOURS and press Tick Use the Up Down keys to select the ON time MINUTES Press Tick to confirm selection Use the Up Down keys...

Страница 35: ...n follow these steps Use the Up Down keys to set the override duration e g 02 00 hours Press Tick to confirm settings and return to main display Hold Left and the remaining time will now be displayed...

Страница 36: ...ction is used to connect the time clock to the neoHub Feature 02 Weekday Weekend 5 2 7 Day Programming or 24 Hour Mode The time clock offers three programming methods Weekday Weekend 5 2 Allows you to...

Страница 37: ...36 Notes 12V...

Страница 38: ...Model Manual REF 37 Notes 37 Series...

Страница 39: ...38 Notes 12V...

Страница 40: ...More Information PDF FAQ Call our support team on 44 0 1254 669090 Or view technical specifications directly on our website www heatmiser com Twitter heatmiseruk Facebook facebook com thermostats Rev...