background image

MF Series 

 

HeatMaster SS Outdoor Furnaces 

  

 

www.heatmasterss.com 

 

INTERIOR CONNECTIONS (continued)

INTERIOR CONNECTIONS (continued)

 

 

 

 

 

DOMESTIC HOT WATER

DOMESTIC HOT WATER

 

 

Flat plate exchanger systems used to pre-heat domestic water tanks are generally easier to install, 
more efficient and more reactive to hot water demands then tube and shell systems.  They are 
mounted on the supply line and use a convection current to heat the water. 

 

FORCED AIR FURNACE (WATER-TO-AIR EXCHANGER) 

The water-to-air heat exchanger must be mounted so that air blows through the fins (coils).  The 
exchanger should be mounted below the A/C coil if possible.  The exchanger should be sized to fit 
existing duct work and should produce about as many BTU’s as the existing heat source.  An 
exchanger that produces too many BTU’s will result in uneven heat and the fan stopping too quickly 
while a heat exchanger that is undersized will not produced the necessary BTU’s.  The heat 
exchanger can also be placed into the cold air portion of the duct work but it is not recommended 
because some furnaces have an overheat shut off if the fan overheats as a result of blowing hot 
instead of cold air

.   

 

It is important that the warm-air supply-duct system be constructed of metal in accordance with NFPA 
90B-1993, 2-1.1 if the outlet-air temperature of a central furnace exceeds 250° F (121° C) when it is 
tested in accordance with the requirements for Simultaneous Firing in 56.4.1 and 56.4.2 of the 
standard.  It is also important that the plenums installed to the furnaces be constructed of metal in 
accordance with NFPA 90B-1993, 2-1.3. 

 

 

 

 

 
 

 

 

 

- 8 -  

Содержание MF-10,000e

Страница 1: ...OR WOOD COAL FURNACES MF MF 3000 3000 MF MF 5 000 MF 5 000 MF 5 000e MF 5 000e MF 10 000e MF 10 000e MF 20 000e 20 000e Model Serial By SteelTech INC By SteelTech INC UL 2523 UL 2523 2009 2009 Version 2 UL 391 1995 UL 391 1995 CAN CSA B366 1 CAN CSA B366 1 M91 M91 ...

Страница 2: ...MF Series HeatMaster SS Outdoor Furnaces www heatmasterss com ...

Страница 3: ...CTION 6 INTERIOR CONNECTIONS 7 OPERATION GUIDE 9 CARE AND MAINTENANCE 10 TROUBLE SHOOTING 11 MF 3000 WIRING DIAGRAM 13 MF 5000 MF 5000e MF 10000e WIRING DIAGRAM 14 MF 20000e WIRING DIAGRAM 15 ETC SETTINGS SPECS 16 WARNINGS SHEET 17 REPLACEMENT COMPONENTS LIST 18 FOOTPRINT CHART 19 SAVE THESE INSTRUCTIONS SAVE THESE INSTRUCTIONS STEELTECH INC BOX 373 WALHALLA ND USA 58282 STEELTECH INC BOX 158 WINK...

Страница 4: ...MF Series HeatMaster SS Outdoor Furnaces www heatmasterss com ...

Страница 5: ...ot responsible for the cost of labor replacement of antifreeze or water treatment shipping cost or any other cost other than the replacement component or furnace SteelTech Inc always has the right to decide if a part or furnace will be repaired or replaced and will not be liable for any cost not authorized by a SteelTech Inc representative SteelTech Inc does not warranty any damage caused due to n...

Страница 6: ...d water treatments which act as oxygen scavengers neutralize harmful bacteria and harmful minerals and elements in your water to reduce scaling and corrosion in your furnace and plumbing system Test Parameters and What They Mean Test Parameters and What They Mean Conductivity Conductivity is a measurement of minerals in your furnace water While it is common to have minerals in water in excess mine...

Страница 7: ...rester is recommended It is the recommendation of SteelTech Inc that a 30 minimum distance of clearance from buildings and other combustibles Your local authorities and your insurance company may require a greater distance RECOMMENDED Choose the location of your furnace with concerns of wind direction smoke odor sparks blocked viewing and wood storage carefully Be a responsible and considerate own...

Страница 8: ...his can lead to improper burning and creosote build up in the furnace FURNACE INSTALLATION GUIDE FURNACE INSTALLATION GUIDE Installation should be performed by a qualified technician LOCATION LOCATION Maintain adequate clearance of buildings and combustibles They are 0 inches from the sides of the furnaces and 3 feet from the front and back Pile and store wood outdoors under cover Do not place or ...

Страница 9: ...educe the pressure generated on the lines WIRING WIRING All wiring must conform to local codes Use an electrical wire rated and approved for underground installations This wiring can be placed in the same trench below the water lines It is recommended that a qualified technician be present when installing the electrical portion of the hook up See Pages 13 15 for the furnace wiring diagrams HYDRONI...

Страница 10: ... is recommended as well as a valve at the return line This will allow you to shut off water supply if repairs or additional heating components are added to the system Your main power is connected to the junction box at the back of furnace and should be connected by a qualified technician 6 RETURN LINE PUMP PLUG IN AND FURNACE POWER SWITCH COMBUSTION FAN FURNACE DRAIN VALVE SOLENOID CIRCULATION PUM...

Страница 11: ...es and suggestions only When installing a furnace and its parts it is best to talk to your local dealer or a qualified technician WATER WATER TO TO WATER HEAT EXCHANGERS WATER HEAT EXCHANGERS To maintain pressure in an existing boiler while using an outdoor furnace a water to water heat exchanger is used The water to water exchanger is installed in line on the supply side of the existing pressuriz...

Страница 12: ...roduce about as many BTU s as the existing heat source An exchanger that produces too many BTU s will result in uneven heat and the fan stopping too quickly while a heat exchanger that is undersized will not produced the necessary BTU s The heat exchanger can also be placed into the cold air portion of the duct work but it is not recommended because some furnaces have an overheat shut off if the f...

Страница 13: ...bage Burning these fuels in your furnace will result in the warranty on the furnace being voided WOOD WOOD On starting an initial fire the use of less coarse wood and paper is required Add heavier fuel gradually until a suitable fire is achieved The furnace will continue to feed an air supply to the fire until your aqua stat shut off temperature is reached ATTENTION ATTENTION On the initial start ...

Страница 14: ...box door by adjusting the hinges on each side of the door Care for the exterior of your furnace is minimal The user must wash and remove ash and creosote regularly Disposal of Ashes Ashes should be placed in a metal container with a tight fitting lid The closed container should be placed on a non combustible floor or on the ground well away from all combustible materials before final disposal If t...

Страница 15: ...ng 2 Check filter cartridge for flow blockage if installed 3 Check for air in the system at the exchanger by bleeding off 4 Check for closed valves to ensure water flow 5 Check Temperature of water exiting furnace entering the building being heated and before and after each heat exchanger If the furnace overheats 1 Check that all doors are closing properly and that door gasket is completely sealin...

Страница 16: ...ce is sized accurately according to heat demand If the furnace is oversized it will idle and cause this If the weather is warm or mild burn a small hot fire using small pieces of wood keeping only enough wood to last until your next burn time generally 12 hour burn time is best It will allow the furnace to burn more often with greater efficiency and have less fuel smouldering during idle creating ...

Страница 17: ...HeatMaster SS Outdoor Furnaces MF Series www heatmasterss com 13 ...

Страница 18: ...MF Series HeatMaster SS Outdoor Furnaces www heatmasterss com 14 ...

Страница 19: ...HeatMaster SS Outdoor Furnaces MF Series www heatmasterss com 15 ...

Страница 20: ...ess either the up or down key to toggle between the C1 or H1 designation This setting must remain at H1 for proper furnace opera tion and temperature regulation Press the SET key once more and programming is com plete NOTE The ETC will automatically end programming if no keys are pressed for thirty seconds Any settings that have been changed on the control will be stored at that point Step Indicat...

Страница 21: ...HeatMaster SS Outdoor Furnaces MF Series www heatmasterss com 17 ...

Страница 22: ...available through your dealer Part Manufacturer s Part 20 Amp Light Up Rocker Switch CRE22F2BBRLE Dayton 4C446 Fan 4C446 Dayton 4C447 Fan 4C447 White Rodgers Fixed Setting Snap Disc Limit Control 3L01 190 Dormeyer 4x240 Solenoid 2005 M 1 Selkirk 18 x 6 Stainless Steel Double Wall Insulated Chimney 206018U Selkirk 6 Single Wall to Double Wall Chimney Adapter 709406 Selkirk 18 x 8 Stainless Steel Do...

Страница 23: ...HeatMaster SS Outdoor Furnaces MF Series www heatmasterss com 19 ...

Страница 24: ......

Отзывы: