HeatMaster SS Outdoor Furnaces
MF Series
www.heatmasterss.com
BUILDING CONNECTIONS
BUILDING CONNECTIONS
A hole large enough to accommodate the water lines, insulation and PVC piping through is important.
Attention to sealing this point with a
weather proof insulation
on both sides is also important.
INTERIOR CONNECTIONS
INTERIOR CONNECTIONS
You may require either a water-to-water (tube and shell or plate) or a water-to-air exchanger (rad) to
transfer heat energy from the hot water your furnace has produced. Your plumber or dealer can
design and install a system to best fit your needs.
IMPORTANT:
It is recommended to always have a back up heating system installed in case of
disruption in the outdoor furnace heating system.
The following are examples of basic interior connections. SteelTech Inc. carry the necessary parts
for installation. Contact us for more info!
DISCLAIMER:
DISCLAIMER: The following information in the interior connections are examples and suggestions
only. When installing a furnace and its parts it is best to talk to your local dealer or a qualified
technician.
WATER
WATER
-
-
TO
TO
-
-
WATER HEAT EXCHANGERS
WATER HEAT EXCHANGERS
To maintain pressure in an existing boiler while using an outdoor furnace a water-to-water heat
exchanger is used. The water-to-water exchanger is installed in-line on the supply side of the existing
pressurized boiler system.
FLAT PLATE EXCHANGER FOR
FLAT PLATE EXCHANGER FOR
PRESSURIZED SYSTEMS
PRESSURIZED SYSTEMS
Flat plate exchanger systems that are
used with pressurized systems such as
in floor heating systems help to heat the
water going in to the pressurized
system while keeping the two systems
separate. Because an outdoor furnace
is an open system (not pressurized)
and the system tied in to in this type of
application is pressurized it allows both
systems to stay the same while being
operational.
The water supplied by the outdoor
furnace will heat the water in the
pressurized system while the present heat source in the pressurized system (such as a boiler) can be
used as a back up heat source in case of emergency or need for additional heat.
- 7 -
Содержание MF-10,000e
Страница 2: ...MF Series HeatMaster SS Outdoor Furnaces www heatmasterss com ...
Страница 4: ...MF Series HeatMaster SS Outdoor Furnaces www heatmasterss com ...
Страница 17: ...HeatMaster SS Outdoor Furnaces MF Series www heatmasterss com 13 ...
Страница 18: ...MF Series HeatMaster SS Outdoor Furnaces www heatmasterss com 14 ...
Страница 19: ...HeatMaster SS Outdoor Furnaces MF Series www heatmasterss com 15 ...
Страница 21: ...HeatMaster SS Outdoor Furnaces MF Series www heatmasterss com 17 ...
Страница 23: ...HeatMaster SS Outdoor Furnaces MF Series www heatmasterss com 19 ...
Страница 24: ......