Electronic Timer Control and Settings
Description
The electronic timer uses the fan to inject air into the
firebox in set intervals. This helps to keep the coal bed
alive during periods of idle.
The Timer is factory set to
off and can be programmed to turn on, if necessary.
Different grades of coal will burn differently so it may be
necessary to try some different settings until an optimal
setting is achieved.
Programming the timer
The timer can be set using the two timing dials and
the dip switch settings.
• The image below shows the timer using settings of
one hour off and one minute on.
• The OFF TIME or yellow side of the timer will control
the how long the fan will be off for
• The ON TIME or black side of the timer will control
how long the fan will be on for
• Make sure that the 4th DIP switch is flipped up.
This will ensure that the timer will start in an “off”
position.
• Make sure that the 5th DIP switch is turned down.
This will make the control function in an OFF/ON
cycle.
The OFF Timer
can be set to run in hours, minutes or
seconds. The first two DIP switches will control what
the time setting will be.
To set the OFF TIME to hours
(recommended)
– The first DIP switch must be turned down
– The second DIP switch must be turned up
To set the OFF TIME to Minutes
– The first DIP switch must be turned up
– The second DIP switch must be turned down
To set the OFF TIME to seconds
– Both DIP switches must be turned down
• The 3rd DIP switch controls the timer settings.
If it is set to the X1 or up setting it will count in
1/10 fractions instead of whole hours, minutes or
seconds.
• The 3rd DIP switch must be set to the X10 or in
the down position. This sets the timer in complete
hours, minutes or seconds.
The ON Timer
can be set to run in hours, minutes or
seconds. The 6th and 7th DIP switches will control
what the time setting will be.
To set the ON TIME to hours
– The 6th DIP switch must be turned down
– The 7th DIP switch must be turned up
To set the ON TIME to Minutes
(recommended)
– The 6th DIP switch must be turned up
– The 7th DIP switch must be turned down
To set the ON TIME to seconds
– Both the 6th and 7th DIP switches must be turned
down
• The 8th DIP switch must be set to the X10 or in
the down position. This sets the timer in complete
hours, minutes or seconds.
• The 8th DIP switch controls the timer settings. If it
is set to the X1 or up setting it will count in 1/10
fractions instead of whole hours, minutes and
seconds.
TIME DIAL
FOR FAN
OFF
DIP
SWITCHES
DIP SWITCH FUNCTION GUIDE
TIME
DIAL FOR
FAN ON
Содержание C-150
Страница 2: ......
Страница 23: ...heatmasterss com 23 ...