DIRECTIONS FOR USE

Your  system  must  be  checked  once  a  year  by  an  approved
installer or maintenance company.

Starting the burner

During operation, the burner starts automatically as soon as 
the boiler temperature drops under the required set point and 
it stops as soon as the boiler reaches that temperature.

Control panel

SETTINGS PARAMETERS

Setting the domestic hot water temperature:

(Hot water temperature)
- Press 

Mode

: The screen displays 

PARA

.

- Press 

Step

: the first character is 

1

 and the last two characters 

give the current hot water temperature setting.

-  To change this temperature, press 

+

 or 

-

 until the last two 

digits show the desired temperature value.

- Press 

Store

 to save the new temperature setting.

- Press 

Mode

 twice to return to Pilot mode (normal operating 

mode).

Enabling or disabling the hot water heating mode:

(hot water)
- Press 

Mode

: The screen displays 

PARA

.

- Press 

Step

 twice: the first character is 

2

 and the last two 

characters give the current setting:

 

00

 = disabled; 

01

 = enabled.

-  To change this parameter, press 

+

 or 

-

 until the screen displays 

the desired value:

 

00

 = disabled; 

01

 = enabled.

- Press 

Store

 to save.

- Press 

Mode

 twice to return to Pilot mode (normal operating 

mode).

Enabling or disabling Central Heating mode:

(heating)
- Press 

Mode

: The screen displays 

PARA

.

- Press 

Step

 three times: the first character is 

3

 and the last 

two characters give the current setting:

 

00

 = disabled; 

01

 = enabled.

-  To change this parameter, press 

+

 or 

-

 until the screen displays 

the desired value:

 

00

 = disabled; 

01

 = enabled.

- Press 

Store

 to save.

- Press 

Mode

 twice to return to Pilot mode (normal operating 

mode).

Setting the central heating temperature:

(maximum temperature for the heating circuit)
- Press 

Mode

: The screen displays 

PARA

.

- Press 

Step

 four times: the first character is 

4

 and the last 

two characters give the current central heating temperature 
setting.

-  To change this temperature, press 

+

 or 

-

  until the last two 

digits show the desired temperature value.

- Press 

Store

 to save the new temperature setting.

- Press 

Mode

 twice to return to Pilot mode (normal operating 

mode).

Fault:

The temperature setting for the appliance and the safety 
functions for its various parts are continuously monitored by 
a regulator controlled by a microprocessor (the MCBA). In the 
event of a fault, this MCBA disables the appliance and displays 
an error code: the screen flashes displaying 

E

 as the first

character, followed by the error code.

To reset the appliance:
- Press "

Reset

" on the screen.

- Contact your installer of the fault happens again.

USERS GUIDE

Heating system

The central heating circuit must be pressurized (see in the 
chapter “Installation” how to define the system pressure).
The pressure indicator is located on the right-hand side of the
display.

  If  your  system  needs  to  be  refilled  more  than  twice 

a year, please contact your installer.

The CH pressure must be a minimum of 1 bar and must be 
checked by the end user on a regular basis. If the pressure 
drops under 0.5 bar, the integrated water pressure switch 
blocks the appliance until the pressure in the system returns to 
a level above 0.8 bar. The connection for a fill valve is provided 
underneath the appliance. The installer can also fit the system 
with a separate valve. Make sure that the appliance is powered 
off when filling the system. To do this, toggle the Start/Stop 
switch located on the left of the screen to Off. 

(see the Control 

panel).

For more information, please ask your installer when the system 
is delivered.

A safety valve is provided at the underneath of the appliance.
If the system pressure exceeds 3 bars, this valve opens and 
drains the water from the system. In this case, please contact 
your installer.

bar

2

1

O

3

4

MCBA display

Pressure gauge

ON/OFF switch

Summer/Winter switch

Pre-cut for an optional
Control Unit controller

Содержание 35 TC

Страница 1: ...EN 1 ENGLISH FRANCAIS NEDERLANDS ESPA OL ITALIANO DEUTSCH 664Y2800 B Installation Operating and Servicing Instructions...

Страница 2: ...ey 12 Connection to the gas 13 Domestic hot water connection 13 Heating connections 14 Installation of a single high temperature circuit with room thermostat ACV 15 control 15 Installation of a weathe...

Страница 3: ...aller must carry out the assembly commissioning maintenance and repair of the system in accordance with current standards in force ACV shall not accept any responsibility for damage caused by non comp...

Страница 4: ...eratures eliminating bacterial formation such as Legionellae as well as resulting in high volume hot water production The down firing flue tubes pass through the upper circuit through the separation p...

Страница 5: ...ion chamber 14 Control panel 15 Primary heating circuit 16 Boiler shunt pump 17 Separation plate 18 Drain cock HeatMaster 85 TC 1 Flue connection concentric 100 150 mm convertible to parallel connecti...

Страница 6: ...ing the flame limiting the temperature etc and control of the boiler temperature This MCBA also includes a weather dependent regulator All you need to do is connect the outdoor temperature sensor avai...

Страница 7: ...nd the last two characters give the current central heating temperature setting To change this temperature press or until the last two digits show the desired temperature value Press Store to save the...

Страница 8: ...46 5 137 148 134 145 Flue gas pipe Max pressure drop Pa 130 130 150 150 Concentric flue gas channel maximum length 80 125 mm m 20 20 20 20 Gas G20 G25 G31 Category varies by country I 2E S B I 2Er I...

Страница 9: ...HU BE CH ES FR UK IE IT PT CZ DK ES FI FR UK IE IT NL NO PT SE AT CH CZ DE FR I 3P G31 30 mbar I 3P G31 37 mbar I 3P G31 50 mbar I 3 G30 G31 28 30 37 mbar I 3B G30 28 30 mbar I 3B G30 50 mbar DOMESTIC...

Страница 10: ...afety contact thermostat RAM optional 21 Ionisation and ignition cable 22 Burner power supply 230 V only HeatMaster 85 TC B Blue Bk Black Br Brown G Grey Or Orange R Red V Violet W White Y Gr Yellow G...

Страница 11: ...the meter ventilate the rooms and contact your installer ACCESSIBILITY The appliance must be positioned in such a way to be accessible any time In addition the following distances are required around...

Страница 12: ...uarantees optimum combustion with very low emission levels To avoid any condensate flow through the terminal the horizontal flue gas pipes must always be installed with a min slope of 5 mm per meter u...

Страница 13: ...the domestic hot water circuit Flush out the system before connecting the domestic hot water part The installation must be fitted with an approved safety unit with a 7 bar safety valve a non return v...

Страница 14: ...representative about the use of inhibitors It is possible that the pumps are locked due to the presence of residual water from tests completed on the appliance Therefore we recommend that you unblock...

Страница 15: ...Typical setting Description 00 Heating mode OFF 01 Heating mode ON Setting temperature for the heating water adjustable between 30 and 85 C 00 Using a outside temperature sensor and a room thermostat...

Страница 16: ...11 module Controls the second heating circuit communicates directly with the MCBA 10800152 HM 35 TC Low temperature kit DN20 Including one circulation pump two isolating valves check valve two thermo...

Страница 17: ...djustable between 15 and 25 C 10 Heating pump controlled by room thermostat hot water priority active 21 Heating pump runs continuously hot water priority active 50 Heating pump controlled by room the...

Страница 18: ...cuit alarm contact operates only in conjonction with the Room Unit RSC 10800152 HM 35 TC X2 Low temperature kit DN20 Including one circulation pump two isolating valves check valve two thermometers th...

Страница 19: ...de OFF 01 Heating mode ON Maximum temperature of the heating circuit must be higher than hot water setpoint AV MPK ZU AUF 0 24V A B VF VE ZMC1 N Y1 Y2 N B A AV MPK ZU AUF 0 24V A B VF VE ZMC1 N Y1 Y2...

Страница 20: ...rs are set in accordance with the user s needs see page 3 Directions for Use Check the boiler settings this task can only be carried out by an ACV trained installer or by the ACV maintenance departmen...

Страница 21: ...bove Remove the burner gasket Clean the combustion chamber using a vacuum cleaner It could be necessary to clean the flue tubes by putting water in the combustion room After that operation it is neces...

Страница 22: ...he temperature two last digits and b with the error code Status Boiler function Standby no demand for heat Fan first fan after Ignition Operation of the boiler burner for the heating Operation of the...

Страница 23: ...hanged The screen flashes once to confirm the data has been saved To activate the parameters you changed press MODE once more which brings you into Info mode However if you do not press a key the syst...

Страница 24: ...as been accepted STORE Press MODE until the system displays the correct mode REQUEST FOR INFORMATION ON THE INSTALLATION Info Mode To switch from Standby to Info mode press Mode twice Key Screen Descr...

Страница 25: ...P Maximum outdoor temperature adjust the heating curve STEP Frost protection temperature STEP Correction of outdoor temperature STEP Blockage T 0 Disabled STEP Acceleration time lag 00 Stop minute STE...

Страница 26: ...minute STEP Domestic hot water pump over run time step 10 2 sec STEP Central Heating modulation hysteresis enabled STEP Central Heating modulation hysteresis disabled STEP Domestic hot water modulati...

Страница 27: ...n possible hot water priority active 50 Controlled circuit outside sensor AM3 11 module heating pump controlled by room thermostat hot water priority not active 61 Controlled circuit outside sensor AM...

Страница 28: ...y Screen Description of parameters STEP Code error of the last lock out STEP Status of the boiler at the time of the error STEP Temperature T1 at the time of the error STEP Temperature T2 at the time...

Страница 29: ...NTC1 is OK please verify that the water flows trough the boiler T2 110 C Check the NTC wiring and replace if necessary T1 gradient too high Check that the pump is turning If there is no problem with...

Страница 30: ...ction of the NTC2 sensor Check the wiring of the NTC2 sensor If the problem persists replace the NTC2 sensor NTC3 connection open Check the connection of the NTC3 sensor Check the wiring of the NTC3 s...

Отзывы: