OPERATING THE DEVICE

Multi Channel support:

Heatit Z-TRM2fx has support for the 

Multi Channel Command 

Class

, and can therefore be seen as many devices by the 

Z-Wave Controller. Where each of the devices has association 
groups in order to send information to other Z-Wave devices, 
see the chapter concerning association groups.

The first Multilevel device reports the temperature for the 
external temperature sensor.
Second Multilevel device reports the temperature for the floor sensor.

Commands sent to each of the logical devices will be 
interpreted according to the description in the section: 
Supporting Command Classes.

No Multi Channel support:

If the Z-Wave Controller, or the Z-Wave devices that shall be 
associated with Heatit Z-TRM2fx, does not support the 

Multi 

Channel Command Class 

(Multichannel encapsulation), then 

only the association groups in the root device is accessible. This 
device will contain 5 association groups. For further information, 
see the chapter concerning association groups. The root device 
is the actual thermostat device.

Supporting Command Classes:

Besides the mandatory command classes, Heatit Z-TRM2fx has 
support for following command classes:

• 

Basic Command Class.

Basic Set

 to the root endpoint or endpoint 1 will change the 

Thermostat Mode.

• 

Binary Switch Command Class.

Sends 

Binary Switch

 Set commands to other devices when the 

internal relay is switched. It can be used to control other slave 
relay devices.

• 

Thermostat Setpoint Command Class.

When a 

Thermostat Setpoint Set

 command is received by the 

root device, it can set the actual setpoints for the three different 
modes the thermostat is able to operate in; Setpoint for the 
heating mode, setpoint for cooling mode and the setpoint for 
energy saving mode.

• 

Thermostat Mode.

It is possible to change the operating mode of the thermostat 
by sending a 

Thermostat Mode Set

 command. This way it is 

possible to set the operating mode to: Heating Mode, Cooling 
Mode or Energy Saving Mode.

Security: 

Heatit Z-TRM2fx is able to operate in security S0 and S2 mode, 
this requires that the device is added in security mode during 
the inclusion process.
It has a QR-code label that can be used when the module is 
included into the Z-Wave home network. The including 
Controller will ask for a 5-digit code, which can be identified 
beneath the QR-code, and will then ask to confirm the rest of the
code that is contained in the QR-code. 

NODE INFORMATION FRAME

The Node Information Frame is the business card of a Z-Wave 
device. It contains information about the device type and the 
technical capabilities. The inclusion and exclusion of the device 
is confirmed by sending out a Node Information Frame. Beside 
this, it may be necessary for certain network operations to send 
out a Node Information Frame.

ASSOCIATIONS

Z-Wave devices control other Z-Wave devices. The relationship 
between one device controlling another device is called 
association. In order to control a different device, the controlling 
device needs to maintain a list of devices that will receive 
controlling commands. These lists are called 

association 

groups

 and they are always related to certain events (e.g. 

sensor reports, ...). In case the event happens all devices stored 
in the respective association group will receive a common 
wireless command.

Association Groups (Multi Channel support):

When using Heatit Z-TRM2fx in a Multi Channel environment:

THERMOSTAT DEVICE 1

THE MAIN THERMOSTAT DEVICE

Group 1

Lifeline. (Normally used by the Z-Wave 

Controller) Sends:

- Device Reset Notifications. 

- Thermostat Setpoint Reports 

- Thermostat Mode Reports

- Basic Reports

- Meter Reports

Max. nodes in group: 8

MULTILEVEL SENSOR 
DEVICE 2

DEVICE FOR EXTERNAL ROOM 
TEMPERATURE SENSOR

Group 1

Group 2

Lifeline

Max. nodes in group: 8

Send Multilevel Sensor Reports. 

Max. nodes in group: 8

MULTILEVEL SENSOR 
DEVICE 3

DEVICE FOR FLOOR SENSOR

Group 1

Group 2

Lifeline

Max. nodes in group: 8

Send Multilevel Sensor Reports. 

Max. nodes in group: 8

BINARY SWITCH 
DEVICE 4

DEVICE FOR THE INTERNAL RELAY

Group 1

Group 2

Lifeline

Max. nodes in group: 8

Send Binary Switch Set commands representing 

the status of the internal relay.

Max. nodes in group: 8

Содержание Z-TRM2fx

Страница 1: ...ncrease reliability of the network On delivery the device does not belong to any Z Wave network The device needs to be added to an existing wireless network to communicate with the devices of this net...

Страница 2: ...e in EU TF 056 HEATIN G L L N HEATIN G N PILOTW IR E FLOOR SENSOR EXTERNAL SENSOR 49 5mm 49 5mm Menu OFF Turns the thermostat off Sensors 1 F Choice of sensors Depending on your choice of sensors the...

Страница 3: ...floor if the thermostat is connected to external sensors By pressing Left or Right up or down button the setpoint will be shown in the display 10 DISPLAY ON OFF DON DOF Activate by pressing Left and C...

Страница 4: ...urity Heatit Z TRM2fx is able to operate in security S0 and S2 mode this requires that the device is added in security mode during the inclusion process It has a QR code label that can be used when th...

Страница 5: ...he desired value VALUE DESCRIPTION 40 40 4 0 C 4 0 C Default is 0 0 0 C Parameter 13 Parameter Size 1 External sensor calibration NB To set a negative value use 255 and subtract the desired value VALU...

Страница 6: ...us Information version 2 Yes Yes Device Reset Locally version 1 Yes Yes Powerlevel version 1 Yes Yes Firmware Update version 4 Yes Yes Multi Channel version 4 Yes Yes Basic version 2 Yes Yes Supervisi...

Страница 7: ...om sensor 5 C 40 C Hysteresis 0 3 C 3 0 C default 0 5 C Switch Single pole switch Included in package Floor sensor Art no 54 301 07 Compatible with NTC sensors with values 10 12 15 22 33 and 47 k 25 C...

Отзывы: