Heatit Z-TRM2fx Скачать руководство пользователя страница 2

Next, position the thermostat and fasten it onto the wall’s 
mounting box using 2-4 screws. Position the frame, then 
position and carefully press the front cover until it snaps in 
place. Check that the front cover has snapped in place properly 
on both left and right side. The front cover should now be firmly 
fixed on all sides.

To be able to to read the Power Metering, the load needs to be 
connected to both heating L + N.

STARTUP

AFTER CONNECTING THE POWER TO THE THERMOSTAT FOR THE 
FIRST TIME, ALL PARAMETERS WILL HAVE DEFAULT SETTINGS.

CONTROL

The thermostat is controlled by three touch sensitive capacitive 
buttons. 
You only need to touch lightly to activate the buttons.
1: Left (Up)
2: Center (Confirm)
3: Right (Down) 

ADDING/REMOVING

To add or remove the thermostat to your home automation 
gateway, press Center (confirm) for 10 seconds.
The display will show OFF. Press Right (down) 4 times till you see 
Con in the display. Now start add/remove device in your home 
automation software. Start adding/removing mode by pressing 
Center (confirm) for approximately 2 seconds. Adding/removing 
Mode is indicated in the display by some “circling” LED segments 
in the display until the timeout occurs after 20 seconds or the 
module has been added/removed in the network. Confirmation 
will show Inc/EcL in the display. If adding/removing fails, Err 
(error) will appear. Leave programming mode by choosing ESC 
in menu. Your thermostat is ready for use with default settings.

PROGRAMMING YOUR THERMOSTAT

To activate the programming mode, press Center (confirm) 
for 10 seconds. Now the display will show OFF.
Now you are in programming mode. To scroll up and down 
in the menu use button 1 and 3 (left and right) to navigate.
To enter submenu press Center (confirm). Always confirm 
your setting by pressing Center (confirm) for 2 seconds.

51,1mm

15,6mm

21,3mm

Z-TRM2fx

Made in EU

TF 056

HEA

TING L

 L

N

HEA

TING N

PIL

OT 

WIRE

FL

OOR

SENSOR

EX

TERNAL

SENSOR

49,5mm

49,

5m

m

Menu:

OFF

  Turns the thermostat off.

 Sensors: 

1. F 

Choice of sensors

Depending on your choice of sensors, the menu will change.

2.  

SEn

  Select the right Ohm value for your external/floor  

   sensor. 
 

 

NTC type (10, 12, 15, 22, 33 or 47kΩ). Default 10kΩ.

3.  

CAE

  Calibration for external sensor.

 CAF

  Calibration for floor sensor.

4.  

br1 

  Brightness of display can be adjusted in this menu.

5. Con

  Activation of inclusion/exclusion mode.

6. diF

 Hysteresis. 

7. ALo

  Setting lowest allowed temperature (limitation).  

   (Airsensor)

 AHI

  Setting highest allowed temperature (limitation).  

   (Airsensor)

 FLO

  Setting lowest allowed temperature (limitation).  

 

 

(Floor sensor)

 FHI

  Setting highest allowed temperature (limitation).  

 

 

(Floor sensor)

 PLo

  Setting lowest allowed power regulator mode.

8. HEA

  Switch between heating and cooling function. 

ESC

 

Escape – exit programming menu.

1. CHOICE OF SENSOR

The thermostat has a range of choices when it comes to  
sensors. To get to the menu you have to press Center (confirm) 
for 10 seconds, then press Right (down) once and an F shows 
in the display. Then press Center (confirm) again and you can 
choose one of these modes, while moving up and down with 
buttons Left or Right. 

F

 

Floor sensor 

A2 

 

External room sensor 

A2F 

  External room Floor sensor

When you have decided on the sensor mode you want to use, 
press the Center (confirm) button. If you choose F without 
having a floor sensor connected, Er4 will be shown in the 
display. If you choose A2 or A2F and there is no external sensor 
installed, Er5 will be displayed on the screen.

NOTE:

 Wooden floors require that a floor sensor is connected 

in order to limit the floor temperature to a maximum of 27°C 
(in accordance with specifications from most wooden floor 
manufacturers).

2. SELECT THE RIGHT OHM VALUE FOR YOUR EXTERNAL 
FLOOR SENSOR 

The following values are available: NTC type (10, 12, 15, 22, 33 or 
47kΩ). Default 10kΩ. The function is only active when an external 
sensor is connected. Confirm with Center (confirm) button.

Содержание Z-TRM2fx

Страница 1: ...ncrease reliability of the network On delivery the device does not belong to any Z Wave network The device needs to be added to an existing wireless network to communicate with the devices of this net...

Страница 2: ...e in EU TF 056 HEATIN G L L N HEATIN G N PILOTW IR E FLOOR SENSOR EXTERNAL SENSOR 49 5mm 49 5mm Menu OFF Turns the thermostat off Sensors 1 F Choice of sensors Depending on your choice of sensors the...

Страница 3: ...floor if the thermostat is connected to external sensors By pressing Left or Right up or down button the setpoint will be shown in the display 10 DISPLAY ON OFF DON DOF Activate by pressing Left and C...

Страница 4: ...urity Heatit Z TRM2fx is able to operate in security S0 and S2 mode this requires that the device is added in security mode during the inclusion process It has a QR code label that can be used when th...

Страница 5: ...he desired value VALUE DESCRIPTION 40 40 4 0 C 4 0 C Default is 0 0 0 C Parameter 13 Parameter Size 1 External sensor calibration NB To set a negative value use 255 and subtract the desired value VALU...

Страница 6: ...us Information version 2 Yes Yes Device Reset Locally version 1 Yes Yes Powerlevel version 1 Yes Yes Firmware Update version 4 Yes Yes Multi Channel version 4 Yes Yes Basic version 2 Yes Yes Supervisi...

Страница 7: ...om sensor 5 C 40 C Hysteresis 0 3 C 3 0 C default 0 5 C Switch Single pole switch Included in package Floor sensor Art no 54 301 07 Compatible with NTC sensors with values 10 12 15 22 33 and 47 k 25 C...

Отзывы: