Heatilator TRADITIONAL 4200 Скачать руководство пользователя страница 24

24

35036 Rev E

12/03

T4200 FIREPLACE INSTALLATION INSTRUCTIONS

CAUTION:

Never use gasoline, gasoline-type lantern fuel,
kerosene, charcoal lighter fluid, or similar liq-
uids to start or “freshen up” a fire in this fire-
place. Keep all such liquids well away from the
fireplace.

Note:

 

 When first lighting your fireplace, it may be

necessary to pre-warm the flue to establish a draft.
This is done by holding a rolled up piece of burning
newspaper under the flue damper for a few moments.
This will help reduce smoke spillage during start-
up.

WARNING!

Fireplaces equipped with doors should be op-
erated only with the doors fully open or fully
closed. If doors are left partially open, gas and
flame may be drawn out of the fireplace open-
ing, creating the risk of both fire and smoke.

Note:

 

 The first three or four fires should be of mod-

erate size to allow the oils and binders to be burned
from the fireplace and the refractory and paint to cure.
You may notice an industrial odor the first few fires.
This is considered normal.

As you use the fireplace, expansion and contraction
will cause minor cracking of the refractory. This is
normal, unavoidable, and will not affect the perfor-
mance of the fireplace. If the cracks become large
enough that the metal behind the refractory is ex-
posed or large pieces fall out, the panels should
be replaced.

SEASONING:

 Seasoned firewood is nothing more than

wood that is cut to size, split and air dried to a moisture
content of around 20%. The time it takes to season
wood varies from around nine months for soft woods
to as long as eighteen months for hardwoods. The key
to seasoning wood is to be sure it has been split,
exposing the wet interior and increasing the surface
area of each piece. A tree that was cut down a year
ago and not split is likely to have almost as high a
moisture content now as it did when it was cut.

The following guideline will ensure properly seasoned
wood:

a.

Stack the wood to allow air to circulate freely
around and through the woodpile.

b.

Elevate the woodpile off the ground to allow air
circulation underneath.

c.

The smaller the pieces, the faster the drying
process. Any piece over six inches in diameter
should be split.

d.

Cover the top of the woodpile for protection from
rain and snow. Avoid covering the sides and ends
completely. Doing so may trap moisture from the
ground and impede air circulation.

The problems with burning wet, unseasoned wood are
twofold: First, you will receive less heat output from
wet wood because it requires energy in the form of
heat to evaporate the water trapped inside. This is
wasted energy that should be used for heating your
home. Secondly, this moisture evaporates in the form
of steam which has a cooling effect in your fireplace
and chimney system. When combined with tar and
other organic vapors from burning wood it will form
creosote which condenses in the relatively cool
fireplace and chimney.

8. Starting a Fire

Check the flue damper to be certain it is in the full open
position. Place crumpled or twisted paper under the
fireplace grate. Loosely arrange kindling or small
pieces of wood to form a layer above the paper.

The fires must be built on the fireplace grate, without
danger of the burning fuel falling out of the fireplace
opening.

Light the paper and add small pieces of wood until a
hot bed of embers has been established.

After establishing the fire bed, and the small firewood
is burning briskly, add a minimum of three average
sized pieces of split firewood, place the wood in such
a manner to allow combustion air and flames between
them.

9. Draft Problems

This fireplace will operate correctly only if adequate
ventilation is provided to allow proper draft to the
fireplace system. Hearth & Home Technologies
assumes no responsibility for the improper
performance of the fireplace system caused by
inadequate draft due to environmental conditions, down
drafts, tight sealing construction of the structure, or
mechanical exhausting devices which will create a
negative air pressure within the structure where the
fireplace is located.

Содержание TRADITIONAL 4200

Страница 1: ...ARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installe...

Страница 2: ...elated problems that may result from the lack of adequate combustion air It is the responsibility of the builder contractor to ensure that adequate combustion air has been provided for the fireplace 4...

Страница 3: ...e of the home If you desire to put a fireplace in your basement we recommend that you consider a direct vent gas fireplace Basements always have a significant negative air pressure that causes the fir...

Страница 4: ...The illustrations and diagrams used throughout these installations instructions are not drawn to scale Figure 1 Typical Fireplace System B DESCRIPTION OF THE FIREPLACE SYSTEM This fireplace system ha...

Страница 5: ...i A e d i s t u O e t a r G l a r g e t n I h t i w e c a l p e r i F 2 4 3 1 M D k c a l B w e i V r a e l C d l o f i B s r o o D s s a l G B 2 4 3 1 M D s s a r B d e h s i l o P w e i V r a e l C...

Страница 6: ...L S g n o l 8 4 n o i t c e S y e n m i h C 1 1 L S r e z i l i b a t S y e n m i h C 0 3 1 1 L S 0 3 n r u t e R t e s f f O y e n m i h C 8 3 5 S F t h g i a r t S p o t s e r i F 0 4 5 S F 0 3 p o...

Страница 7: ...t g n e l h t g n e l e v i t c e f f E s a h t i r e t f a t r a p y e n m i h c r e h t o n a o t d e p p a n s n e e b SL11 Chimney Stabilizer SL1130 Offset Return RF570 Roof Flashing Flat to 6 12...

Страница 8: ...TALLATION INSTRUCTIONS LDS33 3 x 3 LDS46 4 x 6 Decorative Shroud TR11T Round Telescoping Termination Cap ST1175 Square Termination Cap CT56 Chase Top CAK5A Chimney Air Kit TR11 Round Termination Cap T...

Страница 9: ...INSTALLATION PREPARATION 1 Fireplace Locations and Space Requirements Several options are available to you when choosing a location for your fireplace This fireplace may be used as a room divider inst...

Страница 10: ...the fireplace assuming combustible materials are used All required clearances to combustibles around the fireplace must be adhered to Any framing across the top of the fireplace must be above the lev...

Страница 11: ...m the following steps to determine the correct chimney component combination for your particular installation b An offset and return may be attached together or a chimney section s may be used between...

Страница 12: ...eplace installation d Determine the number of firestop spacers stabi lizers roof flashing etc required to complete the fireplace installation 2 Chimney Height Requirements above roof line a Major buil...

Страница 13: ...w the instructions for framing on pages 9 and 10 Slide the fireplace into position Be sure to provide the minimum air clearance at the sides and back of the fireplace assembly 2 Place the Protective M...

Страница 14: ...ard until the top section meets the stop bead on the lower section The inner flue is placed to the inside of the flue section below it The outer casing is placed outside the outer casing of the chimne...

Страница 15: ...unsupported chimney length limitations that are given on page 11 under Chimney Requirements Check each section by pulling up slightly from the top to ensure proper engagement before installing the suc...

Страница 16: ...llowing the instructions shipped with the cap For chase installations you can use a round termination cap TR11 a round telescoping termination cap TR11T or a square termination cap ST1175 A chase inst...

Страница 17: ...r use in this specific model fireplace Unless the unvented gas log heater is tested and listed for use in this factory built fireplace a fire hazard may be created that can result in a structure 16 Ga...

Страница 18: ...n must be installed with all fireplaces to protect the combustible floor in front of the fireplace from both radiant heat and sparks The construction of and materials used for a hearth extension are s...

Страница 19: ...rials are those consisting entirely of steel iron brick tile concrete slate glass or plasters or any combination thereof c Noncombustible Sealant Material Sealants which will not ignite and burn Gener...

Страница 20: ...the 8 level above the fireplace assembly This reduces heat loss through the chase 4 In cold climates the walls of the chase should be insulated to the level of the false ceiling as shown in Figure 21...

Страница 21: ...op Construct a chase of desired materials maintaining a minimum 2 air space around the chimney 3 Termination Cap a Install the chimney sections up through the chase enclosure When using a TR11 round t...

Страница 22: ...Appliances for Installation in Vented Fireplaces ANSI Z21 60 When operating your fireplace the flue damper must be in the open position This fireplace was not tested and listed for use with an unvent...

Страница 23: ...amount of moisture in the wood The majority of the problems fireplace owners experience are caused by trying to burn wet unseasoned wood Freshly cut wood can be as much water as it is wood having a m...

Страница 24: ...wood to allow air to circulate freely around and through the woodpile b Elevate the woodpile off the ground to allow air circulation underneath c The smaller the pieces the faster the drying process...

Страница 25: ...imney is clean and free of creosote buildup Make sure overhanging trees and branches are cut back within ten feet of the top of the chimney Ensure the chimney cap is clean and free of any buildup of s...

Страница 26: ...rred If creosote has accumulated it should be removed to reduce the risk of a chimney fire 3 Chimney Cleaning If you do detect a buildup of creosote contact a qualified chimney sweep or clean it yours...

Страница 27: ...irewood 23 Flue 22 Flue Damper 22 Framing 9 10 Fuel 23 G Gas Codes 17 22 Gas Log Lighter Provisions 17 General Information 22 Glass Doors 19 Operation 23 Grate 23 H Hearth Extension 18 Positioning 19...

Страница 28: ...aust fans or forced air furnaces or other causes 5 use of fuels other than those specified in the Operating Instructions 6 installation or use of components not supplied with the Fireplace or any othe...

Отзывы: