Heatilator TRADITIONAL 4200 Скачать руководство пользователя страница 2

2

35036 Rev E

12/03

T4200 FIREPLACE INSTALLATION INSTRUCTIONS

CAUTION:

Do not expose the fireplace to the elements (i.e. rain, etc.) and keep the fireplace dry at all times. Wet insula-
tion will produce an odor when the fireplace is used.

TABLE OF CONTENTS

Design and Installation Considerations ....................................................................................................... 3

A. Listings and Code Approvals ....................................................................................................................... 4
B. Description of the Fireplace System ............................................................................................................ 4
C. System Components ................................................................................................................................... 5
D. Pre-Installation Preparation ......................................................................................................................... 9
E. Chimney Requirements ............................................................................................................................. 11
F.

Installation of Fireplace ............................................................................................................................. 13

G. Constructing a Chase ................................................................................................................................ 20
H. Operating Instructions ............................................................................................................................... 22
I.

Maintenance Instructions .......................................................................................................................... 26
Index ......................................................................................................................................................... 27
 Warranty .................................................................................................................................................. 28

Safety Precautions

1.

Please read these installation instructions completely before beginning installation procedures. Failure to follow
them could cause a fireplace malfunction resulting in serious injury and/or property damage.

2.

Always check your local building codes prior to installation. The installation must comply with all local, regional,
state and national codes and regulations.

3.

An adequate supply of replacement combustion air from outside the house must be available to the fire for the
fireplace to operate properly. To achieve this, the use of the optional outside air kit is highly recommended.

In the event the home is unusually tightly sealed, the optional combustion air kit may not provide all the air required
to support combustion. Hearth & Home Technologies is not responsible for any smoking or related problems that
may result from the lack of adequate combustion air. It is the responsibility of the builder/contractor to ensure that
adequate combustion air has been provided for the fireplace.

4.

The fireplace must be installed with the Hearth & Home Technologies SL Series Chimney System.

The chimney system must always terminate outside the building. Be sure to follow all chimney specifications given
in these installation instructions.

5.

NEVER

 leave children unattended when there is a fire burning in the fireplace.

6.

This fireplace is built for solid fuel only. 

NEVER

 use gasoline, gasoline type lantern fuel, kerosene, charcoal light

fluid, or similar liquids in this fireplace. Keep any flammable liquids a safe distance from the fireplace.

7.

DO NOT

 use chimney cleaners or flame colorants in your fireplace.

8.

The flue damper must be open at all times when the fireplace is in use.

9.

While servicing this fireplace, always shut off any electricity or gas to the fireplace. This will prevent possible electric
shock or burns. Also, make sure the fireplace is completely cooled before servicing.

10.

To ensure a safe fireplace system and to prevent the build up of soot and creosote, inspect and clean the fireplace
and chimney prior to use and periodically during the burning season. See “Maintenance Instructions” in this manual
for cleaning instructions.

WARNING!

This appliance is tested and listed for use only with the optional accessories listed in these instructions. Use
of optional accessories not specifically tested for this appliance could void the warranty and/or result in a
safety hazard.

Содержание TRADITIONAL 4200

Страница 1: ...ARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installe...

Страница 2: ...elated problems that may result from the lack of adequate combustion air It is the responsibility of the builder contractor to ensure that adequate combustion air has been provided for the fireplace 4...

Страница 3: ...e of the home If you desire to put a fireplace in your basement we recommend that you consider a direct vent gas fireplace Basements always have a significant negative air pressure that causes the fir...

Страница 4: ...The illustrations and diagrams used throughout these installations instructions are not drawn to scale Figure 1 Typical Fireplace System B DESCRIPTION OF THE FIREPLACE SYSTEM This fireplace system ha...

Страница 5: ...i A e d i s t u O e t a r G l a r g e t n I h t i w e c a l p e r i F 2 4 3 1 M D k c a l B w e i V r a e l C d l o f i B s r o o D s s a l G B 2 4 3 1 M D s s a r B d e h s i l o P w e i V r a e l C...

Страница 6: ...L S g n o l 8 4 n o i t c e S y e n m i h C 1 1 L S r e z i l i b a t S y e n m i h C 0 3 1 1 L S 0 3 n r u t e R t e s f f O y e n m i h C 8 3 5 S F t h g i a r t S p o t s e r i F 0 4 5 S F 0 3 p o...

Страница 7: ...t g n e l h t g n e l e v i t c e f f E s a h t i r e t f a t r a p y e n m i h c r e h t o n a o t d e p p a n s n e e b SL11 Chimney Stabilizer SL1130 Offset Return RF570 Roof Flashing Flat to 6 12...

Страница 8: ...TALLATION INSTRUCTIONS LDS33 3 x 3 LDS46 4 x 6 Decorative Shroud TR11T Round Telescoping Termination Cap ST1175 Square Termination Cap CT56 Chase Top CAK5A Chimney Air Kit TR11 Round Termination Cap T...

Страница 9: ...INSTALLATION PREPARATION 1 Fireplace Locations and Space Requirements Several options are available to you when choosing a location for your fireplace This fireplace may be used as a room divider inst...

Страница 10: ...the fireplace assuming combustible materials are used All required clearances to combustibles around the fireplace must be adhered to Any framing across the top of the fireplace must be above the lev...

Страница 11: ...m the following steps to determine the correct chimney component combination for your particular installation b An offset and return may be attached together or a chimney section s may be used between...

Страница 12: ...eplace installation d Determine the number of firestop spacers stabi lizers roof flashing etc required to complete the fireplace installation 2 Chimney Height Requirements above roof line a Major buil...

Страница 13: ...w the instructions for framing on pages 9 and 10 Slide the fireplace into position Be sure to provide the minimum air clearance at the sides and back of the fireplace assembly 2 Place the Protective M...

Страница 14: ...ard until the top section meets the stop bead on the lower section The inner flue is placed to the inside of the flue section below it The outer casing is placed outside the outer casing of the chimne...

Страница 15: ...unsupported chimney length limitations that are given on page 11 under Chimney Requirements Check each section by pulling up slightly from the top to ensure proper engagement before installing the suc...

Страница 16: ...llowing the instructions shipped with the cap For chase installations you can use a round termination cap TR11 a round telescoping termination cap TR11T or a square termination cap ST1175 A chase inst...

Страница 17: ...r use in this specific model fireplace Unless the unvented gas log heater is tested and listed for use in this factory built fireplace a fire hazard may be created that can result in a structure 16 Ga...

Страница 18: ...n must be installed with all fireplaces to protect the combustible floor in front of the fireplace from both radiant heat and sparks The construction of and materials used for a hearth extension are s...

Страница 19: ...rials are those consisting entirely of steel iron brick tile concrete slate glass or plasters or any combination thereof c Noncombustible Sealant Material Sealants which will not ignite and burn Gener...

Страница 20: ...the 8 level above the fireplace assembly This reduces heat loss through the chase 4 In cold climates the walls of the chase should be insulated to the level of the false ceiling as shown in Figure 21...

Страница 21: ...op Construct a chase of desired materials maintaining a minimum 2 air space around the chimney 3 Termination Cap a Install the chimney sections up through the chase enclosure When using a TR11 round t...

Страница 22: ...Appliances for Installation in Vented Fireplaces ANSI Z21 60 When operating your fireplace the flue damper must be in the open position This fireplace was not tested and listed for use with an unvent...

Страница 23: ...amount of moisture in the wood The majority of the problems fireplace owners experience are caused by trying to burn wet unseasoned wood Freshly cut wood can be as much water as it is wood having a m...

Страница 24: ...wood to allow air to circulate freely around and through the woodpile b Elevate the woodpile off the ground to allow air circulation underneath c The smaller the pieces the faster the drying process...

Страница 25: ...imney is clean and free of creosote buildup Make sure overhanging trees and branches are cut back within ten feet of the top of the chimney Ensure the chimney cap is clean and free of any buildup of s...

Страница 26: ...rred If creosote has accumulated it should be removed to reduce the risk of a chimney fire 3 Chimney Cleaning If you do detect a buildup of creosote contact a qualified chimney sweep or clean it yours...

Страница 27: ...irewood 23 Flue 22 Flue Damper 22 Framing 9 10 Fuel 23 G Gas Codes 17 22 Gas Log Lighter Provisions 17 General Information 22 Glass Doors 19 Operation 23 Grate 23 H Hearth Extension 18 Positioning 19...

Страница 28: ...aust fans or forced air furnaces or other causes 5 use of fuels other than those specified in the Operating Instructions 6 installation or use of components not supplied with the Fireplace or any othe...

Отзывы: