Heatilator • ST42A US-CAN • 4012-039 Rev D • 11/07
29
12 in.
(305 mm)
max.
12 in.
(305 mm)
min.
Gas
Knockout
50 deg.
37 deg.
Brick
Front
48 in.
(1219 mm)
(framing)
42 in.
(1067 mm)
(opening)
9-3/4 in.
(248 mm)
14-3/8 in.
(365 mm)
12 in.
(305 mm)
4 in.
(102 mm)
Flush
Front
12 in.
(305 mm)
Figure 8.5 Sidewalls/Surrounds
Fire Risk
Do NOT obstruct air inlet or outlet grilles.
Do NOT modify grilles.
• Modifying or covering grilles could cause
temperature rise and
fi
re hazard.
Finishing materials must not interfere with:
• Air
fl
ow through grilles or louvers
• Operation of louvers or doors
• Access for service
WARNING
Figure 8.4 Mantel Speci
fi
cations
Fire Risk
Finish all edges and fronts to clearances and
speci
fi
cations.
WARNING
• Metal fireplace front may be covered with non-
combustible material only.
• Do NOT overlap combustible materials onto
fi
replace
fronts.
• Install combustible materials up to speci
fi
ed clearances
on top, front and side edges.
• Seal joints between the
fi
nished wall and
fi
replace top
and sides using only a 300° F minimum sealant.
E. Glass Doors
This
fi
replace has been tested and listed for use with doors
as speci
fi
ed in Section 12.B. Fireplace Components. Please
refer to the manual packed with each set of doors for instal-
lation instructions.
D. Sidewalls/Surrounds
Adjacent combustible side walls must be located a minimum
of 12 in. (305 mm) from the
fi
replace opening. If you are us-
ing a decorative surround constructed of combustible ma-
terial, it must be located within the shaded area de
fi
ned in
Figure 8.5. Short stub walls are also acceptable if they are
contained within the shaded area.
C. Mantel
A combustible mantel may be positioned no lower than
12 in. (305 mm) above the top of the
fi
replace openings. The
combustible mantel may have a maximum depth of 12 in.
(305 mm). Combustible trim pieces that project no more than
1 in. (25 mm) from the faces of the
fi
replace can be placed
no closer than 6 in. (152 mm) from the top of the
fi
replace
openings. See Figure 8.4. Combustible trim must not cover
the metal surfaces of the
fi
replace. This mantel clearance is
in accordance with
Section 7-3.3.3 of ANSI/NFPA211
.