Heatilator • RAVE32-IFT-B, RAVE36-IFT-B, RAVE42-IFT-B Installation Manual • 2619-983 Rev. U • 9/22
4
This product is listed to ANSI standards for “Vented
Gas Fireplace Heaters” and applicable sections of “Gas
Burning Heating Appliances for Manufactured Homes
and Recreational Vehicles”, and “Gas Fired Appliances
for Use at High Altitudes”. Also Certified for Installation in
a Bedroom or a Bedsitting Room.
A. Appliance Certification
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen
-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
NOTICE:
This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
1
1
Product Specific and Important Safety Information
D. High Altitude Installations
NOTICE:
If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce input rate 4% for each 1000 feet
above 2000 feet.
• In CANADA: Input ratings are certified without a
reduction of input rate for elevations up to 4500 feet
(1370 m) above sea level. Please consult provincial and/
or local authorities having jurisdiction for installations at
elevations above 4500 feet (1370 m).
Check with your local gas utility to determine proper
orifice size.
B. Glass Specifications
Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous lo
-
cations such as bathtub enclosures as defined by the
Consumer Product Safety Commission (CPSC). The
tempered glass has been tested and certified to the re
-
quirements of
ANSI Z97.1
and
CPSC 16 CFR 1202
(Safety Glazing Certification Council
SGCC# 1595
and
1597
. Architectural Testing, Inc. Reports
02-31919.01
and
02-31917.01
).
This statement is in compliance with
CPSC 16 CFR Sec-
tion 1201.5
“Certification and labeling requirements”
which refers to
15
U.S. Code
(USC) 2063
stating “…Such
certificate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered.”
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
C. BTU Specifications
MODELS:
RAVE42-IFT-B, RAVE36-IFT-B,
RAVE32-IFT-B
LABORATORY:
Underwriters Laboratories, Inc. (UL)
TYPE:
Direct Vent Heater
STANDARD:
CSA / ANSI Z21.88-2019 • CSA 2.33-2019
Models
(U.S. or Canada)
Maximum
Input BTU/h
Minimum
Input BTU/h
Orifice
Size
(DMS)
RAVE42-IFT-B
(NG)
(0-2000 FT)
25,250
17,500
#42
RAVE42-IFT-B
(PROPANE)
(0-2000 FT)
23,500
17,500
.057
RAVE36-IFT-B
(NG)
(0-2000 FT)
20,500
14,500
#44
RAVE36-IFT-B
(PROPANE)
(0-2000 FT)
19,000
14,000
#55
RAVE32-IFT-B
(NG)
(0-2000 FT)
19,000
13,250
#45
RAVE32-IFT-B
(PROPANE)
(0-2000 FT)
16,500
12,750
1.25
mm