Heatilator • RAVE32-IFT-B, RAVE36-IFT-B, RAVE42-IFT-B Installation Manual • 2619-983 Rev. U • 9/22
30
Note
: Use SLP Series
components only.
V
1
H
1
H
3
H
2
INSTALLED
HORIZONTALLY
INSTALLED
HORIZONTALLY
V Minimum
H
1
+ H
2
+ H
3
MAXIMUM
RAVE42-IFT-B
RAVE36-IFT-B
(NG ONLY)
4 ft.
1.2 m
15 ft.
4.6 m
H
1
+ H
2
+ H
3
MAX. = 15 ft. (4.6 m)
V
1
MAX. = 7 ft (2.1 m)
Risk of Fire!
This vent configuration can ONLY be used for
RAVE36-IFT-B and RAVE42-IFT-B Natural Gas
appliances.
WARNING
CAUTION:
The SLP-HRC-SS termination caps are
not approved for use with these models.
May lead to
elevated glass temperature that may cause tempered
glass breakage.
Figure 4.15
Three Elbows
Note
: There MUST be a 25% reduction
in total H when using SLP-FLEX Series
(6-5/8 inch) vent except when using
the simple up and out installation. See
Figure 4.10.
Top Vent - Horizontal Termination - (continued)