47
Heatilator • NDV30-IFT, NDV33-IFT, NDV36-IFT, NDV36-IFT-NVR, NDV42-IFT Installation Manual • 2620-980 Rev. C • 8/20
Figure 8.2 IntelliFire
Touch Wiring Diagram
IntelliFire
®
Touch Ignition System Wiring
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT
wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.2 IntelliFire Touch (IPI) Wiring Diagram.
• This appliance is equipped with an IntelliFire control
valve which operates on a 6 volt system.
B. Wiring Requirements
FLAME SENSE
2090-012 (NG)
2090-013 (P)
IGNITER
ADAPTER
2326-131
I
S
6 PIN
2326-132
ORANGE
(PILOT)
GREEN
(MAIN)
RF MODULE 2326-120
(FOR USE WITH OPTIONAL
REMOTE CONTROL)
ELECTRONIC CONTROL MODULE
2326-130
VALVE
2166-302 (NG)
2166-303 (P)
FAN
(OPTIONAL)
IFT-ACM
(OPTIONAL)
NOTE: IFT-ACM includes
ACM power cord.
6V DC
BATTERY PACK
2326-134
RED
BLK
RED
JUMPER
WIRE
APPLIANCE
ON/OFF
CONTROL
BRN
BLK
JUNCTION BOX
110-120 VAC
2326-013
IFT-RC400
REMOTE
CONTROL
(OPTIONAL)
IFT-RC150
WIRELESS
WALL SWITCH
(OPTIONAL)
IFT-WFM
WIFI MODULE
(OPTIONAL)
Wi-Fi MODULE 2326-137
(OPTIONAL)