Heatilator • NDI30-C, NDI30-SP, NDI35-C, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-901 Rev. K • 11/12
16
B. Design and Installation Considerations
Heatilator gas inserts are designed for installations into
solid fuel masonry or factory built fi replaces that have
been installed in accordance with the National, Provin-
cial, State and local building codes. Fireplaces are to be
constructed of non-combustible materials and, in the ab-
sence of local or regional codes, meet criteria of NFPA
211. No additional outside air source is required.
Installation MUST comply with local, regional, state and na-
tional codes and regulations. Consult insurance carrier, local
building inspector, fi re offi cials or authorities having jurisdic-
tion over restrictions, installation inspection and permits.
Prior to installing the gas insert:
• Have the chimney and adjacent structure inspected
and cleaned by qualifi ed professionals. Hearth & Home
Technologies recommends that NFI or CSIA certifi ed
professionals, or technicians under the direction of certi-
fi ed professionals, conduct a minimum of a NFPA 211
Level 2 inspection of the chimney.
• Replace component parts of the chimney and fi replace
as specifi ed by the professionals.
• Ensure combustible mantel and surround clearances
comply with applicable codes and regulations for solid-
fuel fi replaces. In the absence of local or regional codes,
refer to NFPA 211.
• Ensure all joints are properly engaged and the chimney
is properly secured.
• Minimum fi replace size. See Section 5.A.
• Gas supply piping requirements.
• Electrical wiring requirements.
• Finishing details.
• Whether optional accessories—devices such as a wall
switch or remote control—are desired.
D. Inspect Appliance and Components
• Carefully remove the appliance and components from
the packaging.
• The vent system components and decorative doors and
fronts may be shipped in separate packages.
• If packaged separately, the log set and appliance grate
must be installed.
• Report to your dealer any parts damaged in shipment,
particularly the condition of the glass.
•
Read all of the instructions before starting the instal-
lation. Follow these instructions carefully during the
installation to ensure maximum safety and benefi t.
WARNING! Risk of Fire or Explosion! Damaged parts
could impair safe operation. DO NOT install damaged, in-
complete or substitute components. Keep appliance dry.
C. Tools and Supplies Needed
Before beginning the installation be sure that the following
tools and building supplies are available.
Tape measure
Framing material
Pliers
Flat blade screwdriver
Hammer Phillips
screwdriver
Gloves Framing
square
Voltmeter
Electric drill and bits (1/4 in.)
Plumb line
Safety glasses
Level Reciprocating
saw
Manometer
Noncorrosive leak check solution
1/2 - 3/4 inch length, #6 or #8 Self-drilling screws
Caulking material (300ºF minimum continuous exposure
rating)
Stove cement (1200ºF or higher continuous exposure
rating)
Hearth & Home Technologies disclaims any responsibility for,
and the warranty will be voided by, the following actions:
• Installation and use of any damaged appliance or vent
system component.
• Modifi cation of the appliance or vent system.
• Installation other than as instructed by Hearth & Home
Technologies.
• Improper positioning of the gas logs or the glass door.
• Installation and/or use of any component part not approved
by Hearth & Home Technologies.
Any such action may cause a fi re hazard.
WARNING! Risk of Fire,/Explosion/Electric Shock!
DO NOT use this appliance if any part has been under
water. Call a qualifi ed technician to inspect the appliance
and to replace any part of the control system and/or gas
control which has been under water.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. For
assistance or additional information, consult a qualifi ed
technician, service agency or your dealer.