MH SERIES INSTALLATION INSTRUCTIONS
WARNING!
This fireplace and its components are designed to be installed and operated as a system. Any alteration to or
substitution for items in this system, unless allowed by these installation instructions, will void the Underwrit-
ers Laboratories listing and may void the product warranty. It may also create a hazardous installation. Read
through these instructions thoroughly before starting your installation and follow them carefully throughout
your project.
Figure 1 - Typical Fireplace System
1. The Heatilator fireplace system consists of the
following:
a.
Fireplace/Integral Grate/Outside Combustion Air
System
b.
Refractory
c.
Chimney Termination Cap
d.
Chimney System
e.
Hearth Extension
f.
Glass Doors
The CP311 Convenience Pack has been designed for
the convenience of customers wishing to install a
chimney system at the 11 ft minimum straight height.
The CP313 Convenience Pack has been designed for
those wishing to install a chimney system at the 13 ft
minimum straight height.
The following combination of listed parts are included
in both the CP311 and CP313 Convenience Packs:
Note:
Illustrations used throughout these instructions
reflect “typical installations” and are for design purposes
only. Actual installation may vary slightly due to individual
design preferences. However, minimum and maximum
clearances must be maintained at all times.
The illustrations and diagrams used throughout these
installation instructions are not drawn to scale.
B. DESCRIPTION OF THE FIREPLACE SYSTEM
This fireplace system has been tested and listed in
accordance with
UL-127
and
ULC-S610
standards, and
has been listed by Underwriters Laboratories Inc. for
installation and operation in the United States as described
in this manual.
This fireplace has been tested and listed for use with the
optional components listed on page 5. These optional
components may be purchased separately and installed at
a later date. However, installation of an outside air kit will
require significant reconstruction, and should be installed
at the time of the initial fireplace installation.
Check with your local building code agency prior to
installing this fireplace to ensure compliance with local
codes, including the need for permits and follow-up
inspections. If you need assistance during installation,
please contact your local dealer or the Heatilator Technical
Services Department, Hearth Technologies Inc., 1915 W.
Saunders St., Mt. Pleasant, Iowa 52641 (1-800-927-6841).
Heatilator® is a registered trademark of Hearth
Technologies Inc.
A. LISTINGS AND CODE APPROVALS
2. Optional Components include:
a.
Chimney Air Kit
b.
Glass Doors
Manufactured Housing Convenience Packs
Cat. #
CP311
Qty.
CP313
Qty.
Description:
SL324
1
2
Chimney Section - 24 in. long
SL336
2
2
Chimney Section - 36 in. long
MH842
1
1
Roof Thimble and Flashing
TR344
1
1
Round Termination Cap