background image

28

17804 Rev i

08/04

HEATILATOR WOODBURNING FIREPLACE

LIMITED WARRANTY

As part of its

20-YEAR BUYER PROTECTION PROGRAM

AS PART OF ITS 20 YEAR BUYER PROTECTION PROGRAM (“PROGRAM”), HEARTH & HOME TECHNOLOGIES INC. (“HHT”)

 

is

pleased to offer a Limited Warranty and a Replacement Parts Advantage covering specific components of your Heatilator

 woodburning

fireplace system ( the “Fireplace”), installed in the United States of America or Canada.  Dealers and employees of 

HHT

 have no authority to

make any warranty or authorize any remedies in addition to or inconsistent with the terms of this Program

.

Limited Warranty

HHT

 warrants the following components of your Heatilator woodburning fireplace to be free from original defects in material and workmanship

during the applicable periods described: five years for the firebox assembly, chimney system and roof termination; two years for refractory
firebox liners; and one year for the grate, wire mesh screens, fan system, outside air system, and glass doors.  All limited warranty periods
run from the date of initial installation of your Fireplace (the “Installation Date”).  The Limited Warranty is subject to the conditions, exclusions
and limitations of liability listed below.

Replacement Parts Advantage

Under 

HHT

’s Replacement Parts Advantage, for a period of twenty years from your Installation Date of your Fireplace, if available, 

HHT

 will

provide you with repair or replacement parts for defective components which are no longer under their applicable Limited Warranty, at 50%
of the then current retail list price for such components.  

HHT

 shall have no responsibility for freight and labor charges related to such parts.

Conditions, Exclusions, & Limitations of Liability

A.

Both the Limited Warranty and Replacement Parts Advantage supplied by 

HHT

 apply only while the Fireplace is in its location of

original installation.  

HHT

’s obligation under this warranty does not extend to damages resulting from (1) installation, operation or

maintenance of the Fireplace not in accordance with the Installation Instructions, Operating Instructions, and the Listing Agent Identification
Label furnished with the Appliance; (2) installation which does not comply with local building codes; (3) shipping, improper handling,
improper operation, abuse, misuse, accident or unworkmanlike repairs; (4) environmental conditions, inadequate ventilation or drafting
caused by tight sealing construction of the structure, air handling devices such as exhaust fans or forced air furnaces, or other
causes;  (5) use of fuels other than those specified in the Operating Instructions; (6) installation or use of components not supplied
with the Fireplace or any other components not expressly authorized and approved by 

HHT

; and/or (7) modification of the Fireplace not

expressly authorized and approved by 

HHT

 in writing. This warranty is limited to only the component parts manufactured or supplied

by 

HHT

.

B.

During the first year of the Limited Warranty, 

HHT

 will, at its sole option, repair or replace any covered defective component and will

provide replacement parts at no charge. And will pay reasonable labor and freight costs.  During the second through the fifth years of
the Limited Warranty (if applicable), 

HHT

 will provide replacement parts free of charge for any covered defective component, but will

not pay for freight or labor costs related to the shipment of the parts or the actual repair or replacement.  After the fifth anniversary of
the Installation date, 

HHT

’s sole obligation and your exclusive remedy is set forth in 

HHT

’s Replacement Parts Advantage described

above.  

In no event shall HHT be liable for any incidental or consequential damages caused by defects in your Fireplace.

C.

EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE   WARRANTY SPECIFIED
HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE WARRANTY SPECIFIED ABOVE.

D.

Some states do not allow exclusions or limitations of incidental or consequential damages, so those limitations may not apply to you.
This warranty gives you specific rights; you may also have other rights which vary from state to state.

How to Obtain Service

1.

To obtain service under this warranty you must:

2.

Send written notice of the claimed condition to Heatilator Technical Service Department, Hearth & Home Technologies, 1915 W. Saunders
Street, Mt. Pleasant, Iowa 52641-1563.  You may also register your claim online at www.heatilator.com/contact.asp.

3.

Provide proof of purchase, model number, serial number, and manufacturing date code to 

HHT

.

4.

Provide 

HHT

 reasonable opportunity to investigate the claim, including reasonable opportunity to inspect the Appliance prior to any

repair or replacement work and before the Appliance or any component of the Appliance has been removed from the place of original
installation.

5.

Obtain 

HHT

’s consent to any warranty work before the work is done.

ADDITIONAL INFORMATION: 

If you would like information on current HEATILATOR products or want to locate a dealer in your area, call

1-800-927-6841.

2003 Heatilator is a Registered Trademark of Hearth & Home Technologies Inc.

Содержание MH36A

Страница 1: ...ury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier INSTALLATION OPERATING INSTRUCTIONS MH36A MH39A MH42A WOODBURNING FIREPLACE FOR MANUFACTURED HOUSING Note An arrow found in the text signifies change in content ...

Страница 2: ... problems that may result from the lack of adequate combustion air It is the responsibility of the builder contractor to ensure that adequate combustion air has been provided for the fireplace 4 The fireplace must be installed with the Hearth Home Technologies SL Series Chimney System The chimney system must always terminate outside the building Be sure to follow all chimney specifications given i...

Страница 3: ...of the home If you desire to put a fireplace in your basement we recommend that you consider a direct vent gas fireplace Basements always have a significant negative air pressure that causes the fireplace system to be more susceptible to smoke spillage and cold flue back drafting Since direct vent gas fireplaces are sealed they are not affected by the negative pressure that exists in basements Fin...

Страница 4: ...However minimum and maximum clearances must be maintained at all times The illustrations and diagrams used throughout these installation instructions are not drawn to scale B DESCRIPTION OF THE FIREPLACE SYSTEM This fireplace system has been tested and listed in accordance with UL 127 and ULC S610 standards and has been listed by Underwriters Laboratories Inc for installation and operation in the ...

Страница 5: ...earth Extension DM1036 DM1039 DM1042 Original Bifold Glass Doors Black Finish DM1036B DM1039B DM1042B Original Bifold Glass Doors Polished Brass Finish included with fireplace DM1036S DM1039S DM1042S Original Bifold Glass Doors Stainless Steel Finish DP1036 none DP1042 Perception Glass Doors Black Finish DP1036B none DP1042B Perception Glass Doors Polished Brass Finish DP1036S none DP1042S Percept...

Страница 6: ...36 in long SL348 Chimney Section 48 in long SL315 Chimney Offset Return 15 deg SL330 Chimney Offset Return 30 deg JB877 Chimney Joint Band CB876 Chimney Bracket TR344 Round Termination Cap CP311 Manufactured Housing Convenience Pack 11 ft CP313 Manufactured Housing Convenience Pack 13 ft MH841 Manufactured Housing 20 in Thimble Extension MH842 Manufactured Housing Thimble and Flashing RF370 Roof F...

Страница 7: ...4 17804 Rev i 7 MH SERIES INSTALLATION INSTRUCTIONS Offset Return TR344 Round Termination Cap with Storm Collar JB877 Joint Band CB876 Chimney Bracket CAK4A Chimney Air Kit MH841 MH842 Roof Thimble Flashing ...

Страница 8: ...ch RF371 Roof Flashing 6 12 to 12 12 Pitch Firestop Spacer Catalog A B FS338 0 deg 14 1 2 in FS339 15 deg 18 3 8 in FS340 30 deg 23 in Catalog A B SL306 6 in 4 3 4 in SL312 12 in 10 3 4 in SL318 18 in 16 3 4 in SL324 24 in 22 3 4 in SL336 36 in 34 3 4 in SL348 48 in 46 3 4 in A Actual Length B Effective length length of chimney part after it has been snapped to another ...

Страница 9: ...d doors central heat outlets or returns or other locations of considerable air movement can affect the performance and cause intermittent smoke spillage from the front of the fireplace Consideration should be given to these factors before deciding on a location CLEARANCES A minimum 1 2 in air clearance must be maintained at the back and sides of the fireplace assembly Chimney sections at any level...

Страница 10: ...ber of the fireplace assuming combustible materials are used All required clearances to combustibles around the fireplace must be adhered to Any framing across the top of the fireplace must be above the level of the top standoffs Chimney sections at any level require a 2 in minimum air space clearance between the framing and chimney section CLEARANCES A minimum 1 2 in air clearance must be maintai...

Страница 11: ...ested to provide flexibility in construction The following figures are the minimum distances from the base of the fireplace 1 Minimum overall straight height 13 ft 2 Minimum height with offset return 14 5 ft 3 Maximum height 90 ft 4 Maximum chimney length between an offset and return 20 ft 5 Maximum distance between chimney stabilizers 35 ft 6 Double offset return minimum height 24 ft 7 Maximum un...

Страница 12: ... 4 Read across the chart and find the number of chimney sections required and the model number of those particular chimney parts 5 Whenever the chimney penetrates a floor ceiling a firestop spacer must be installed 6 The effective height of the fireplace assembly is measured from the base of fireplace to top of starter collar See Figure 6 Example Your A dimension from Figure 7 is 14 1 2 in Using T...

Страница 13: ...tes If the horizontal distance from the side of the chimney to the peak of the roof is 10 ft or less the top of the chimney must be at least 2 ft above the peak of the roof but never less than 3 ft in overall height above the highest point where it passes through the roof If the horizontal distance from the side of the chimney to the peak of the roof is more than 10 ft a chimney height reference p...

Страница 14: ...tructions for framing on pages 9 11 Slide the fireplace into position Be sure to provide the minimum air clearance at the sides and back of the fireplace assembly 2 Place the Protective Metal Hearth Strips Included with your fireplace you will find two metal hearth strips measuring approximately 26 in x 4 in These strips are used to provide added protection where the fireplace and the hearth exten...

Страница 15: ...op bead on the lower section The inner flue is placed to the inside of the flue section below it The outer casing is placed outside the outer casing of the chimney section below it See Figure 10 5 Install the Firestop Spacers Mark and cut out an opening in the ceiling for the firestop spacer being utilized 14 1 2 in x 14 1 2 in for an FS338 14 1 2 in x 18 3 8 in for an FS339 and 14 1 2 in x 23 in ...

Страница 16: ... unsupported chimney length limitations that are given on page 11 under Chimney Requirements Check each section by pulling up slightly from the top to ensure proper engagement before installing the succeeding sections If they have been connected correctly they will not disengage when tested 8 Secure the Chimney System When offsets and returns are joined to straight pipe sections they must be locke...

Страница 17: ...The MH841 Thimble Extension is required when the ceiling roof thickness exceeds 12 1 2 in The extension should overlap the thimble 1 in c To attach the extension to the thimble drill 1 8 in holes through the outer shield of the thimble using the predrilled holes in the extension as guides Attach the extension to the thimble using the screws provided with the extension d Install the thimble assembl...

Страница 18: ...he fireplace Remove the cover plate from the side of the fireplace assembly where the air kit is to be installed Install the outside air kit as detailed in the installation instructions included with it See Figure 16 for handle location operation Figure 17 Installing a TR344 Round Termination Cap WARNING Detailed instructions for installation of the termination cap and storm collar are packaged wi...

Страница 19: ...tories Inc for use in this specific model fireplace Unless the unvented gas log heater is tested and listed for use in this factory built fireplace a fire hazard may be created that can result in a structure 13 Gas Log Lighter Provisions Knockouts are provided on both sides of the fireplace to allow for connection of a certified gas log lighter or a decorative gas appliance with a maximum input of...

Страница 20: ...replace from both radiant heat and sparks The construction of and materials used for a hearth extension are shown in Figures 19 and 20 A hearth extension of this construction may be covered with any noncombustible decorative material and may have a maximum thickness as per the illustration Seal gaps between the hearth extension and the front of the fireplace with a bead of noncombustible sealant F...

Страница 21: ...hose consisting entirely of steel iron brick tile concrete slate glass or plasters or any combination thereof c Noncombustible Sealant Material Sealants which will not ignite and burn General Electric RTV103 Black or equivalent Rutland Inc Fireplace Mortar 63 or equivalent After completing the framing and applying the facing material dry wall over the framing a 1 2 in wide maximum bead of noncombu...

Страница 22: ...Appliances for Installation in Vented Fireplaces ANSI Z21 60 When operating your fireplace the flue damper must be in the open position This fireplace was not tested and listed for use with an unvented gas log heater Do not install an unvented gas log heater in this fireplace and operate it with the flue damper in the closed position unless the unvented gas log heater has been specifically tested ...

Страница 23: ...a greater density than soft woods A piece of hardwood will contain about 60 more BTU s than an equal size piece of soft wood Firewood is commonly sold by the cord 128 cu ft A cord of seasoned oak hardwood would contain about 60 more potential energy than a cord of seasoned pine soft wood Soft woods are generally considered coniferous These are trees with needle like leaves that stay green all year...

Страница 24: ...e wood to allow air to circulate freely around and through the woodpile b Elevate the woodpile off the ground to allow air circulation underneath c The smaller the pieces the faster the drying process Any piece over 6 in in diameter should be split d Cover the top of the woodpile for protection from rain and snow Avoid covering the sides and ends completely Doing so may trap moisture from the grou...

Страница 25: ...ney is clean and free of creosote buildup Make sure overhanging trees and branches are cut back within ten feet of the top of the chimney Ensure the chimney cap is clean and free of any buildup of soot or creosote If you still suspect you have a low draft problem it may be necessary to increase the volume of air in your flue system Since the diameter of your flue system is matched with the size of...

Страница 26: ...urred If creosote has accumulated it should be removed to reduce the risk of a chimney fire 3 Chimney Cleaning If you do detect a buildup of creosote contact a qualified chimney sweep or clean it yourself To do this perform the following steps a Open the damper b Hang a damp sheet across the fireplace opening to stop dirt and soot from entering the room c Remove the termination cap or housing top ...

Страница 27: ...5 Firewood 23 Flashing 17 Flue 22 Framing 10 Fuel 23 G Gas Codes 19 22 Gas Knockout Location 6 Gas Log Lighter Provisions 19 General Information 22 Glass Doors 5 21 Grate 5 23 H Hearth Extension 20 Positioning 21 I Insulation Shield 8 16 J Joint Band 7 L Leveling the Fireplace 14 Locations 9 M Mantel 10 11 21 Material Sealant 21 Metal Hearth Strips 14 Moisture Content of Wood 23 N Noncombustible M...

Страница 28: ...haust fans or forced air furnaces or other causes 5 use of fuels other than those specified in the Operating Instructions 6 installation or use of components not supplied with the Fireplace or any other components not expressly authorized and approved by HHT and or 7 modification of the Fireplace not expressly authorized and approved by HHT in writing This warranty is limited to only the component...