26
30484 Rev Q
09/04
MAXUS DIRECT VENT HEATER
b.
Standing Pilot Ignition
1)
This standing pilot appliance does
not
require a 110VAC supply to operate. It is
suggested that a 110V junction box be
installed with a switched outlet for the
optional fan and an always-powered outlet
for the optional remote control.
2)
Only heater listed appliances may be
connected to a thermostat (not supplied).
Use a thermostat that is compatible with a
millivolt gas valve. See Figure 37.
Note:
This appliance must be electrically wired and
grounded in accordance with local codes or, in the ab-
sence of local codes, with
National Electric Code ANSI/
NFPA 70-latest edition
or the
Canadian Electric Code
CSA C22.1
.
WARNING!
This standing pilot appliance DOES NOT require a
110VAC supply for operation. Connecting the appli-
ance/wall switch to 110VAC supply will cause the
appliance to malfunction and destroy the valve and
thermopile.
CAUTION:
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after
servicing.
Figure 37 - Standing Pilot Ignition Wiring Diagram
c.
Junction Box Wiring
We recommend you operate the two outlets on
separate circuits. This allows independent
operation of the appliance and fan. Independent
operation is obtained by using minimum 14-3
with ground romex and separating the two outlets
by breaking out the tab as shown. See Figure 38.
Figure 38