39
Heatilator • LEGACY42-IFT Installation Manual • 4095-901 Rev. A
• 12/17
Figure 11.4
•
Set Left & Right Side Refractories in place. See Fig
-
ure 11.5.
Refractory Installation
Note
: Unpack refractory panels carefully to avoid damag
-
ing the panels.
•
Remove smoke shield (5) screws and set the smoke
shield aside.
•
Set Back Refractory in place and secure with (1) re
-
fractory retainer. See Figure 11.4.
D. Refractory Kit
The LEGACY refractory kit includes the following com-
ponents:
•
Back Refractory
•
Left & Right Side Refractory
•
Left & Right Side Hearth Refractory
•
Left, Right & Middle Front Hearth Refractory
Refractory Retainer
Note: Reference the Homeowner’s Manual for instruc-
tions about remote setup and operation.
•
Press the speed select button to cycle through and
select proper speed settings for your installation. See
Figure 11.3.
•
IMPORTANT; Mark the appropriate speed using the
S1 or S2 box located on the speed control label for
future reference. See Figure 11.3.
Note: The selected speed is now the default speed seting
whenever the appliance is placed into operation.
Figure 11.3
Figure 11.5
S1/S2 Speed Indicator
S1/S2 Selection Box
Speed Select