Heatilator ION-H7 Скачать руководство пользователя страница 18

Heatilator  • ION-V7, ION-S7, ION-H7 Owner’s Manual  •  2276-981 Rev. E  •  5/17 

18

B.  Troubleshooting - IntelliFire™ Plus Ignition System

With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.  If you do 
experience a problem, this troubleshooting guide will assist a quali

fi

 ed service technician in the diagnosis of a problem and 

the corrective action to be taken. This troubleshooting guide can only be used by a quali

fi

 ed service technician.  Contact 

your dealer to arrange a service call by a quali

fi

 ed service technician.

Symptom

Possible Cause

Corrective Action

1. Pilot won’t light. 

The ignitor/module 
makes noise, but no 
spark.

A.  Incorrect wiring.

Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor are 
connected to correct terminals on module and pilot assembly.

B.  Loose connections or electrical 

shorts in the wiring.

Verify no loose connections or electrical shorts in wiring from mod-
ule to pilot assembly. Verify connections underneath pilot assembly 
are tight; also verify igniter and 

fl

 ame sense wires are not grounding 

out to metal chassis, pilot burner, pilot enclosure, mesh screen if 
present, or any other metal object. 

C.  Ignitor gap is too large.

Verify gap of igniter to right side of pilot hood. The gap should be 
approximately .17 in. or 1/8 in. (3 mm).

2. Pilot won’t light, 

there is no noise or 
spark.

A.  No power, transformer installed 

incorrectly, or depleted batteries.

Verify that transformer is installed and plugged into module. Check 
voltage of transformer at connection to module. Acceptable read-
ings of a good transformer are between 6.4 and 6.6 volts DC.  Bat-
tery power supply voltage must be at least 4 volts.  If less than 4 
volts, replace batteries.

B.  A shorted or loose connection in 

wiring con

fi

 guration or wiring har-

ness.

Remove and reinstall the wiring harness that plugs into module. 
Verify there is a tight 

fi

 t. Verify pilot assembly wiring to module. Re-

move and verify continuity of each wire in wiring harness.  Replace 
any damaged components.

C.  Improper wall switch wiring.

Verify that 110-120 VAC power is “ON” to junction box.

D.  Module not grounded.

Verify black ground wire from module wire harness is grounded to 
metal chassis of appliance.

3. Pilot sparks, but 

Pilot will not light.

A.  Gas supply.

Verify that incoming gas line ball valve is “open”. Verify that inlet 
pressure reading is within acceptable limits.

B.  Ignitor gap is too large.

Verify gap of igniter to right side of pilot hood. The gap should be 
approximately .17 in. or 1/8 in. (3 mm).

C.  Module is not grounded.

Verify module is securely grounded to metal chassis of appliance.

D.  Pilot valve solenoid. 

Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid from module.  
If below 1.5 volts, replace module.  If 1.5 volts or greater, replace 
valve.

Содержание ION-H7

Страница 1: ...in your building Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire d...

Страница 2: ...De Gaz Gaz N NA ATURAL TURAL GAS GAS MADE MADE IN IN USA USA Minimum Minimum Permissible Permissible Gas Gas Supply Supply for for Purposes Purposes of of Input Input Adjustment Adjustment Approved A...

Страница 3: ...ce Certification 6 B Glass Specifications Ceramic 6 C BTU Specifications 6 3 General Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Wall Surface TV Guidelines 9...

Страница 4: ...n the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independe...

Страница 5: ...Y EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may...

Страница 6: ...est edition in the U S A and the CAN CGA B149 Installation Codes in Canada 2 2 Product Specific and Important Safety Information B Glass Specifications Ceramic This appliance is equipped with 5 mm cer...

Страница 7: ...en and others may be susceptible to accidental contact burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to a fireplace or stove install an adjus...

Страница 8: ...losion Appliance must be set up for compatible gas type This appliance is designed to operate on either natural gas or propane Make sure the appliance is compatible with gas type selected for installa...

Страница 9: ...is fireplace for the first time have a qualified service technician Verify all shipping materials have been removed from inside and or underneath the firebox Check the wiring Check the air shutter adj...

Страница 10: ...iance Hot while in operation DO NOT touch Keep children clothing furniture gasoline and other liquids having flammable vapors away DO NOT operate the appliance with fixed glass assembly removed cracke...

Страница 11: ...ly and run continuously on high an additional 8 12 hours This cures the materials used to manufacture the fire place NOTICE Open windows for air circulation during fire place break in Some people may...

Страница 12: ...igure 3 3 for location The decorative front or door will need to be removed See Section 4 B for decorative front removal information 2 Locate the battery tray and insert four AA cell batteries Battery...

Страница 13: ...ring diagram is included in the Electrical section of the appliance installation manual 5 Module Reset This module may lock out under certain conditions When this occurs the appliance will not ignite...

Страница 14: ...bly with care Glass is breakable Avoid striking scratching or slamming glass Avoid abrasive cleaners DO NOT clean glass while it is hot Prepare a work area large enough to accommodate fixed glass asse...

Страница 15: ...snow debris etc Verify termination cap clearance to subsequent construc tion building additions decks fences or sheds Inspect for corrosion or separation Verify weather stripping sealing and flashing...

Страница 16: ...objects Verify unobstructed air circulation Burner Ignition and Operation Frequency Annually By Qualified Service Technician Tools needed Protective gloves vacuum cleaner whisk broom flashlight voltme...

Страница 17: ...on abrasive cleaner such as gas fireplace glass cleaner may be necessary See your dealer Metallic noise Noise is caused by metal expanding and contracting as it heats up and cools down similar to the...

Страница 18: ...ximately 17 in or 1 8 in 3 mm 2 Pilot won t light there is no noise or spark A No power transformer installed incorrectly or depleted batteries Verify that transformer is installed and plugged into mo...

Страница 19: ...de of pilot hood Flame sensing rod should glow shortly after ignition With a multi meter verify that current in series between module and sense lead is at least 0 14 microamps Verify correct pilot ori...

Страница 20: ...your dealer for a list of ap proved accessories WARNING Risk of Fire and Electric Shock Use ONLY Hearth Home Technologies approved optional acces sories with this appliance Using non listed accessori...

Страница 21: ...______________________________________________ ________________________________________________________________________________ ________________________________________________________________________...