10/03
32912 Rev L
7
GENEVA SERIES B-VENT GAS APPLIANCE
Figure 3 shows typical framing of this appliance using
combustible materials. Figures 3 and 4 show the minimum
mantel height. All required clearances to combustibles must
be adhered to.
C. FRAMING
Figure 3 - Framing
WARNING!
To prevent contact with sagging or loose insula-
tion, the appliance must not be installed against
vapor barriers or exposed insulation.
Figure 4
Mantel Heights
CAUTION:
Wear gloves and safety glasses for protection.
CAUTION:
Provide adequate clearances around the air
openings into the combustion chamber and
adequate accessibility clearances for servicing and
proper operation.
GGBR60/80 MINIMUM MANTEL HEIGHT
This appliance may be placed on a smooth combustible or noncombustible continuous, flat surface. When the appliance
is installed directly on carpeting, tile, or a combustible material other than wood flooring, the appliance shall be installed
on a metal or wood panel extending the full width and depth of the appliance. Slide the appliance into position and level
from side-to-side and front-to-back. Shim with noncombustible material as necessary.
Secure the appliance by bending out the nailing flanges on each side of the appliance and nail to framing. The nailing
flanges have been positioned 5/8 back from the front of the appliance to allow the addition of drywall.
D. SETTING THE APPLIANCE