
24
30803 Rev X
08/04
CALIBER DIRECT VENT INSTALLATION INSTRUCTIONS
6. Junction Box Installation Instructions
a.
If the box is being wired from the OUTSIDE of
the appliance:
1)
Remove the cover plate located on the outer
shell (right side).
2)
Install the supplied Romex connector in the
cover plate.
3)
Loosen two screws on the Romex connector,
feed the necessary length of wire through
the connector and tighten the screws.
4)
Make all necessary wire connections and
reattach the cover plate to the outer shell.
b.
If the box is being wired from the INSIDE of the
appliance:
1)
Remove the screw attaching the junction box
to the outer shell, rotate the junction box
inward to disengage it from the outer shell.
2)
Pull the electrical wires from outside the
appliance through this opening into the valve
compartment.
3)
Loosen the two screws on the Romex
connector, feed the necessary length of wire
through the connector and tighten the screws.
4)
Make all necessary wire connections to the
receptacle and assemble the receptacle and
cover to the junction box.
Figure 51 - Junction Box Detail
c.
If the box is being wired to a wall mounted switch or BC10 for use with a fan (See Figure 52):
1)
The power supply for the appliance must be brought into a switch box.
2)
The power can then be supplied from the switch box to the appliance using a minimum of 14-3 with ground
wire.
3)
At the switch box connect the black (hot) wire and red (switch leg) wire to the wall switch or BC10 as shown.
4)
At the appliance connect the black (hot), white (neutral) and green (ground) wires to the junction box as
shown.
5)
Route the red (switch leg) wire through the knockout in the face of the junction box and connect to the top fan
switch connector (1/4 in. male) as shown.
Figure 52 - Junction Box Wired to Wall Switch or BC10
f i r e - p a r t s . c o m