09/04
31282 Rev Q
17
CALIBER B-VENT INSTALLATION INSTRUCTIONS
H. APPLIANCE PREPARATION
1. Attach the Hood
The hood is to be located above the glass panel. The
hood must be attached or a fire hazard may result.
Locate the four screws just inside the upper section
of the appliance. Position the hood and slide into
position. Tighten the four screws. See Figure 17.
2. Remove the Upper Panel Grille
Grasp the upper grille panel and remove the rubber
pins holding the grille. See Figure 18.
3. Remove the Control Access Panel
Release the spring pin on the right hand side of the
control access panel. See Figure 19.
4. Remove the Glass and Screen
See page 24 of this manual.
5. Prepare the Appliance
Remove the strap from the screws on the hearth pan.
Remove the foam material. The log set should look
similar to that in Figure 20.
Figure 17 - Attaching the Hood
Figure 18 - Upper Grille Panel Removal
WARNING - RISK OF CARBON MONOXIDE!
Do not hit or strike glass. Do not operate this appli-
ance if the glass is broken or cracked.
WARNING - RISK OF CARBON MONOXIDE!
Never operate this appliance with the glass removed
or not sealed.
Figure 20 - CALIBER Log Set (CALIBER 60 shown)
Figure 19 - Control Access Panel Removal
f i r e - p a r t s . c o m