CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED.
D
E
B
L
C
V
V
B
F
V
B
V
V
B
X
A
J
Fixed
Closed
M
V
K
X
RESTRICTION ZONE
(TERMINATION NOT
ALLOWED)
AIR SUPPLY INLET
X
GAS METER
V TERMINATION CAP
H
B
Openable Fixed
Closed
V
I
V
O
N
Q
P
R
T
S
Electrical
Service
V
U
V
U
V
W
D*
V
V
Covered Alcove
Applications
Clearances to Electrical Service
A
V
V
G
Measure horizontal clearances
from this surface.
Measure vertical clearances
from this surface
'LPHQVLRQ'HVFULSWLRQV
$ &OHDUDQFHDERYHWKHJURXQGDYHUDQGDSRUFKGHFNRUEDOFRQ\
LQFPPLQLPXP
% &OHDUDQFH WR ZLQGRZ RU GRRU WKDW PD\ EH RSHQHG ± %78V
RUOHVVLQFPPLQLPXP%78VLQFP
PLQLPXPRYHU%78VLQFPPLQLPXP
& &OHDUDQFHWRSHUPDQHQWO\FORVHGZLQGRZ±LQFPPLQLPXP
UHFRPPHQGHGWRSUHYHQWFRQGHQVDWLRQRQZLQGRZ
' 9HUWLFDO FOHDUDQFH WR YHQWLODWHG VRI¿W ORFDWHG DERYH WKH WHUPLQDWLRQ
ZLWKLQDKRUL]RQWDOGLVWDQFHRIIWFPIURPWKHFHQWHUOLQHRIWKH
WHUPLQDWLRQ±LQFPPLQLPXP
( 9HUWLFDOFOHDUDQFHWRXQYHQWLODWHGVRI¿WLQFPPLQLPXP
) &OHDUDQFHWRRXWVLGHFRUQHULQFPPLQLPXP
* &OHDUDQFHWRLQVLGHFRUQHULQFPPLQLPXP
+ 1RWWREHLQVWDOOHGDERYHDPHWHUUHJXODWRUDVVHPEO\ZLWKLQIW
FPKRUL]RQWDOO\IURPWKHFHQWHUOLQHRIWKHUHJXODWRU&DQDGDRQO\
,
&OHDUDQFHWRVHUYLFHUHJXODWRUYHQWRXWOHW±IWP86PLQLPXP
DQGIWP&DQDGDPLQLPXP
- &OHDUDQFH WR QRQPHFKDQLFDO DLU VXSSO\ LQOHW LQWR EXLOGLQJ RU WKH
FRPEXVWLRQDLULQOHWWRDQ\RWKHUDSSOLDQFH±´FP86PLQLPXP
DQGLQFP&DQDGDPLQLPXP
. &OHDUDQFHWRPHFKDQLFDODLUVXSSO\LQOHWIWP86PLQLPXP
DQGIWP&DQDGDPLQLPXP
/ &OHDUDQFHDERYHDSDYHGVLGHZDONRUSDYHGGULYHZD\ORFDWHGRQSXEOLF
SURSHUW\IWPPLQLPXP
$YHQWPD\QRWWHUPLQDWHGLUHFWO\DERYHDVLGHZDONRUSDYHGGULYHZD\
ZKLFKLVORFDWHGEHWZHHQWZRVLQJOHIDPLO\GZHOOLQJVDQGVHUYHVERWK
GZHOOLQJV
0 &OHDUDQFH XQGHU YHUDQGD SRUFK GHFN RU EDOFRQ\ LQ FP
PLQLPXP5HFRPPHQGHGLQFPIRUYLQ\ORUSODVWLF
2QO\SHUPLWWHGLIYHUDQGDSRUFKGHFNRUEDOFRQ\LVIXOO\RSHQRQD
PLQLPXPRIVLGHVEHQHDWKWKHÀRRU
1 9HUWLFDOFOHDUDQFHEHWZHHQWZRKRUL]RQWDOWHUPLQDWLRQFDSV±LQ
FPPLQLPXP
2 +RUL]RQWDOFOHDUDQFHEHWZHHQWZRKRUL]RQWDOWHUPLQDWLRQFDSV±LQ
FPPLQLPXP
3 ´1RQYLQ\OVLGHZDOOV
´±9LQ\OVLGHZDOOV
4 ´±1RQYLQ\OVRI¿WDQGRYHUKDQJ
´±9LQ\OVRI¿WDQGRYHUKDQJ
S
min
T
max
FDS
IW
[6DFWXDO
FDSV
IW
[6DFWXDO
FDSV
IW
[6DFWXDO
FDSV
IW
[6DFWXDO
S
PLQ
WHUPFDSV[
T
PD[
WHUPFDSV[6DFWXDO
5 IW
8 ´PLQ±&OHDUDQFHIURPVLGHVRIHOHFWULFDOVHUYLFH
: ´PLQ±&OHDUDQFHDERYHHOHFWULFDOVHUYLFH
$VVSHFL¿HGLQ&*$%,QVWDOODWLRQ&RGHV
1RWH/RFDOFRGHVRUUHJXODWLRQVPD\UHTXLUHGLIIHUHQWFOHDUDQFHV
&OHDUDQFHUHTXLUHGWRYLQ\OVRI¿WPDWHULDO±LQFPPLQLPXP
1RWH/RFDWLRQRIWKHYHQWWHUPLQDWLRQPXVWQRWLQWHUIHUHZLWKDFFHVV
WRWKHHOHFWULFDOVHUYLFH
:$51,1*
,Q WKH 86 9HQW V\VWHP WHUPLQDWLRQ LV 127 SHUPLWWHG LQ VFUHHQHG
SRUFKHV<RXPXVWIROORZVLGHZDOORYHUKDQJDQGJURXQGFOHDUDQFHV
DVVWDWHGLQWKHLQVWUXFWLRQV
,Q &DQDGD 9HQW V\VWHP WHUPLQDWLRQ LV 127 SHUPLWWHG LQ VFUHHQHG
SRUFKHV9HQWV\VWHPWHUPLQDWLRQLVSHUPLWWHGLQSRUFKDUHDVZLWKWZR
RUPRUHVLGHVRSHQ<RXPXVWIROORZDOOVLGHZDOORYHUKDQJDQGJURXQG
FOHDUDQFHVDVVWDWHGLQWKHLQVWUXFWLRQV
+HDUWK +RPH7HFKQRORJLHVDVVXPHVQRUHVSRQVLELOLW\IRUWKHLPSURSHU
SHUIRUPDQFHRIWKHDSSOLDQFHZKHQWKHYHQWLQJV\VWHPGRHVQRWPHHW
WKHVHUHTXLUHPHQWV
Figure 6.3 Minimum Clearances for Terminations