7057-143A • 20 August, 2018
Heatilator EcoChoice WS22
15
www.heatilator.com
Burn Rate
Air Control
Handle Up = Open
Handle Down = Closed
Blower
Snap Disc
Figure 16.1
NOTE:
If your wood appliance is equipped with an
optional blower, you should follow these
guidelines:
Figure 16.2 - Snap Disc Location
M. Blower Operating Instructions
1. Initial (cold) startup:
Open both controls fully by
raising the Burn Rate Air Control all the way up until
it stops and push the Start-up Air Control back until it
stops.
The blower tends to cool the appliance. Leave
the blower off until the burn is well established, i.e., 30
minutes.
2. High Burn Setting:
Both controls are open. Burn Rate
Air Control is pulled up and the Start-up Air Control is
fully pushed in. Blower may remain on.
3. Medium High Burn Setting*:
Burn Rate Air Control
is closed then opened to 1 inch (pull up )to fully open.
Blower may remain on.
4. Medium
Low Burn Setting*:
Burn Rate Air Control
is closed then opened to 1/4 inch to 1/2 inch. Leave
the blower off until the burn is well established, i.e., 30
minutes.
5. Low Burn Setting*:
Burn Rate Air Control is closed.
Leave the blower off until the burn is well established,
i.e., 30 minutes.
When reloading the appliance, raise the Burn Rate
Air Control all the wall to the High setting for 5 to 15
minutes before setting to the desired burn rate.
6. The blower is equipped with a rheostat (speed control).
The highest blower speed is obtained by turning the
rheostat on, then adjusting back towards “OFF” as far
as possible without turning the blower off. For a low
blower speed, turn the control knob clockwise as far as
possible
*NOTE:
For burn settings 3 to 5 the Start-up Air Control
needs to be pushed in (Open) then pulled forward
to activate the Automatic Combustion Control
(ACC).
NOTE:
For maximum efficiency and lowest emissions,
when operating the blower in either the automatic
or manual setting for the low and medium low
burn settings leave the blower off until the burn is
well established, i.e., 30 minutes.
7. Snap Disc Location:
If you find the blower coming
on and off at undesirable temperatures, relocate the
snap disc to another location in the designated zone
on the back of the appliance
(Figure 16.2)
. There is a
manual over-ride switch to deactivate the snap disc, if
necessary. See page 39 for location of over-ride switch.
N. Clear Space
•
Do NOT place combustible objects within 4 ft (1.2 m) of
the front of appliance
(Figure 17.1)
.
• Mantel - avoid placing candles and other heat-sensitive
objects on mantel or hearth. Heat may damage these
objects.
Figure 17.1
Maintain 4 ft. (1.22m) clearance to
combustible in front of appliance
WARNING
Do NOT place combustible objects in front of the
appliance. High temperatures may ignite clothing, furniture
or draperies.