R
R
39
Heatilator • ECO-ADV-PS35/50 • 7058-142D • July 21, 2010
Figure 38.3 - Rear Vent Adapter
1
.
A low voltage thermostat is required to operate this
pellet appliance. You may use the included wall mount
thermostat
(Figure 39.2)
or purchase an optional pro-
grammable thermostat or remote control. It is equipped
with an adjustable heat anticipator. The current rating is
.05 amps. The anticipator needs to be adjusted to the
lowest setting available.
2. When mounting a thermostat on a wall, be sure to follow
your thermostat installation instructions carefully.
NOTE: Thermostat must be mounted level for accu
-
rate readings. The thermostat should be mounted on
an inside wall and not in direct line with the appliance
convection air.
NOTE: If the thermostat is located too close to the
appliance, you may need to set the temperature
setting slightly higher to maintain the desired tem
-
perature in your home.
3. There is a 4 screw terminal block located on the back
lower left corner of the stove directly above the power
cord inlet. The center 2 screws are for the thermostat
wires.
Figure 39.1.
D. Thermostat Installation
Figure 39.1
Shock hazard.
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded 3 prong
receptacle.
• Route cord away from appliance.
•
Do NOT route cord under or in front of appli
-
ance.
CAUTION
Figure 39.2
Back of Appliance
Terminal Block
Center 2 Screws for
Thermostat Wires
Power Outlet