Heatilator • CD4236-MOD, CD4842-MOD Owner’s Manual • 2241-902 Rev. C • 11/15
12
G. Appliance Break-In
Initial Break-in Procedure
• The fireplace should be run three to four hours
continuously on high.
• Turn the
fi
replace off and allow it to completely cool.
• Remove
fi
xed glass assembly. See Section 4.B.
• Clean
fi
xed glass assembly. See Section 4.
• Replace the
fi
xed glass assembly and run continuously
on high an additional 12 hours.
This cures the materials used to manufacture the
fi
re-
place.
NOTICE! Open windows for air circulation during
fi
re-
place break-in.
• Some people may be sensitive to smoke and odors.
• Smoke detectors may activate.
H. Heat Management
Heat Output
Heat output can be controlled by optional remote control
or by adjusting hi/lo switch on IntelliFire™ Plus control
module.
ON/OFF
SWITCH
CONTROL
CAVITY
3.5 ON/OFF Switch/ Control Cavity Location
I. Operation During A Power Outage
The IntelliFire™ Plus intermittent pilot ignition system
comes with a battery backup system that enables the
system to operate in a power outage. The system offers
seamless transition from household AC power to battery
backup. A factory-installed battery pack is located in the
control cavity of the appliance. See Figure 3.5. Battery
longevity and performance will be affected by long term
exposure to the service temperatures of this appliance.
NOTICE:
Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Standard Wall Switch or Factory-Installed ON/OFF
Switch:
• Toggle the switch as you would under normal
circumstances.
Wireless Remote:
• Remote receiver is integrated into the ignition module.
• Use the remote to turn the appliance on.
• To preserve battery life, do not use the HI/LO
fl
ame or
THERMOSTAT options.
Ignition Module:
• Locate the ignition module in the control cavity.
• Slide the ON/REMOTE/OFF switch to the ON position.
To Return to Operation Using Electrical (AC) Power
Standard Wall Switch or Factory-Installed ON/OFF
Switch:
• Toggle the switch to OFF and remove the batteries
from the battery tray. Replace door or decorative front
on appliance.
Wireless Remote:
• Slide the ON/REMOTE/OFF switch to the REMOTE
position. Remove the batteries from the battery tray.
Replace door or decorative front on appliance.
Ignition Module:
• Slide the ON/REMOTE/OFF switch to the REMOTE
position.
Remove the batteries from the battery tray. Replace
door or decorative front on appliance.
NOTICE:
Some functionality will be lost when using battery
backup including remote control, fan, lights, or any other
auxiliary functions that require household 110-120 VAC
power.
To Operate Fireplace Using Battery Power (DC):
1. Access the control cavity of the appliance. See Figure
3.2 for location. The decorative front or door may
need to be removed.
2. Locate the battery tray and insert four AA cell batteries.
Battery polarity must be correct or module damage
will occur. See Figure 3.5. A complete wiring diagram
is included in the Electrical section of the appliance
Installation Manual.
3. Turn the appliance on according to the instructions
below for the appropriate type of control: