Heatilator • ICON DV-IDV Series • 4042-575 • Rev. S • 5/11
42
NOTICE:
DO NOT wire
110 VAC to wall switch.
E. Junction Box Installation
If the junction box is being wired from OUTSIDE of the
appliance (
preferred method
):
•
Remove two screws that attach junction box and bracket
to appliance. See Figure 13.2.
• Feed an appropriate length of romex through plastic
romex connector.
• Make necessary electrical connections.
• Attach outlet and cover plate to junction box.
•
Reattach junction box and bracket to appliance with two
screws.
Figure 13.2 Remove Two Screws From Bracket
If the junction box is being wired from the INSIDE of the
appliance:
• Remove one screw that attaches access panel to
column. See Figure 13.3.
• Remove two screws that attach junction box to junction
box bracket. See Figure 13.4.
• Feed an appropriate length of romex through plastic
romex connector.
• Reattach junction box to junction box bracket with two
screws.
• Make necessary electrical connections.
• Attach outlet and cover plate to junction box.
• Reattach cover plate to column with one screw.
Figure 13.3 Remove Access Panel Screw
Figure 13.4 Remove Two Screws Holding Junction Box