![Heatiator IDV4833IH Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/heatiator/idv4833ih/idv4833ih_owners-manual_2116933019.webp)
Heatilator • ICON DV-IDV Series • 4042-575 • Rev. S • 5/11
19
Measured from top of fireplace opening (in inches)
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
11-1/2
12-1/4
13
13-3/4
14-1/2
15-1/4
16
16-3/4
17-1/2
18-1/4
19
19-3/4
20-1/2
21-1/4
22
22-3/4
30 in. minimum
to ceiling
1
2
10
10-3/4
D. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be construct-
ed entirely of non-combustible materials (i.e., steel studs,
concrete board, etc).
Figure 5.3
Minimum Vertical and Maximum Horizontal Dimensions
1 in. (25 mm) min.
to perpendicular wall
A
7.75 in. (159 mm) min.
from fireplace opening
to perpendicular wall
B
Mantel Leg or
Perpendicular Wall
Top of
Appliance
Drywall
A
B
Figure 5.4
Mantel Leg or Wall Projections (Acceptable on both sides of opening)
Mantels
Mantel Legs or Wall Projections