background image

Solar Powered
Motion Sensor Light

Model SH-7001

FeatureS

•  Turns on light when motion is detected.
•  Automatically turns light off.
•  Photocell keeps the light off during daylight hours.
• 

Battery Protection Circuitry. Unit will shut down when 
battery is low. Unit will automatically resume operation 
when battery is recharged to a safe level.

requireMentS

•  Do not turn the light on before the battery is fully charged. 

Charge the battery by keeping the switch in the OFF 
position and the solar collector pointed directly at the 
noon sun for 3 sunny days. If not fully charged, the unit 
will not work.

•  When  FULLY  charged,  the  solar  light  will  operate  a 

maximum of 15 days without sunlight. Actual operating 
time will vary depending upon how frequently the light 
is triggered.

Light

Battery 
Case

Sensor

3. Mounting Screws (2 sizes)

1. Solar Light Fixture

2. Solar Panel

Tapered Screw (3)

Round Head Screw (2)

unPaCking

Be sure to remove all contents from packaging and verify 
all items are present before assembling this light fixture. 
This package includes the following items:

inStaLLatiOn

For best performance, mount the fixture about 8 feet (2.4 
m) above the ground.

1. 

Mount solar panel base on a solid surface using 

three tapered screws

. Adjust the panel to point directly 

at the noon sun. Avoid obstructions such as trees or 
buildings that may block sun light. Allow for enough 
wire to reach the case. 

keep ball joint at bottom.

 

Note:

 You will want to re-aim the solar panel as the 

seasons change to keep it pointed directly at the noon 
sun.

Three Mounting Holes for Solar Panel Base

2. 

Mount the battery case on a solid surface using 

two round-head screws

 and the keyholes on the 

back of the case.

3. 

adjust  sensor.  For  proper  operation,  the  sensor 
head must be rotated so that the sensor controls face 
downward as shown below.

3

/

4

"

Mounting Holes (3)

Mounting 
Holes (2)

4.  Plug the solar panel cable into the bottom of the battery 

case. 

IMPORTANT:

  allow  the  battery  to  charge 

with three days of sunshine before testing.

Controls

Light

Battery Case

Sensor Joint 
Clamp 

IMPORTANT:

 the controls must face downward to 

avoid damage from rain. If controls face upward, move 
sensor to the original down position, rotate 180°, then 
raise to the position shown below.

Light Joint Clamps

Lense Removal 
Tab

Sensor

© 2007 HeathCo LLC 

598-1164-04

Содержание Secure Home SH-7001

Страница 1: ...owing items INSTALLATION For best performance mount the fixture about 8 feet 2 4 m above the ground 1 Mount solar panel base on a solid surface using threetaperedscrews Adjustthepaneltopointdirectly at the noon sun Avoid obstructions such as trees or buildings that may block sun light Allow for enough wire to reach the case Keep ball joint at bottom Note You will want to re aim the solar panel as ...

Страница 2: ...F position Mode On Time Works Day Night Test 5 Seconds x x Auto 30 Seconds x Things To Remember Periodically clean the solar panel with a soft cloth and warm water Do not hose spray Keep the collector clear of snow and leaves Make sure trees and other objects do not block sunlight from the panel If not to be used for several weeks turn the unit OFF Store it with the panel connected and where the p...

Страница 3: ...sold IMPORTANT Replacelamponlywithsametypelamp 20 watts or less DO NOT reverse the battery wires Damage to the unit will result Like any lead acid battery this battery must be disposed of properly IMPORTANT Keep sensor switch in the OFF position for three days to allow the battery to fully charge before testing 1 Remove rear battery cover Press in the two catch releases on the cover and remove the...

Страница 4: ...e on 1 Battery is dead 2 Sensor is turned OFF 3 Lamp is loose or burned out 4 Daylight turn off is in effect 5 Incorrect aiming 1 Switch the sensor OFF and let the battery charge for three or more sunny days before using again 2 Turn sensor ON 3 Check lamp and replace if burned out 4 Recheck after dark 5 Re aim the sensor to cover desired area Lights come on in daylight 1 Light control may be inst...

Страница 5: ...ntaje para la base del panel solar 2 Monte la caja de la batería sobre una superficie sólida usando dos tornillos de cabeza redonda y los orificios en la parte de atrás de la caja 3 Acomode el Detector Para una operación correcta la cabeza del detector debe girarse de modo que los controles del detector queden ubicados hacia abajo como se muestra a continuación 17 15 cm Orificios de montaje 3 Orif...

Страница 6: ...de Unión Esférica Tornillo Sujetador Regulación del Área de Cobertura El detector detecta movimiento por el movimiento del calor calor corporal a través del área de cobertura Sin embargo a continuación están ejemplos de objetos que pueden producir calor y hacer que el detector active una falsa alarma Charcos de agua Acondicionadores de aire Ventosas de la secadora Animales en vallas Ventosas de ca...

Страница 7: ...nel conectado y en un sitio donde el panel pueda guardar la luz solar Lacolecciónsolaressoloefectivabajolaluzdirectadel sol Por cada hora que la luz está prendida requiere un mínimo de 16 horas de carga de luz solar Los paneles solares recolectan menos del 10 de la energÌa solar Las bombillas convierten esta energÌa en luz con una eficiencia del 5 Si la usa durante varios días nublados la batería ...

Страница 8: ...ha de compra cualquier mal funcionamiento ocasionado por partes defectuosas de fábrica o mano de obra será corregido sin cargo para Ud No cubierto Servicio de reparación ajuste y calibración debido al mal uso abuso o negligencia bombillas baterías u otras partes fungibles no están cubiertas por esta garantía Los Servicios no autorizados o modificaciones del producto o de cualquier componente que s...

Страница 9: ... du panneau solaire 2 Installer le boîtier de la pile sur une surface so lide au moyen des deux vis à tête ronde en vous servant des orifices en trou de serrure à l arrière du boîtier 3 Régler le capteur Pour fonctionner correctement le capteur doit être placé de façon que les commandes soient face au sol comme illustré ci dessous 17 15 cm Orifices de fixation 3 Orifices de fixation 2 2007 HeathCo...

Страница 10: ...mouvements en décelant le passage d une source de chaleur chaleur corporelle dans la zone de couverture Voici toutefois des exem ples d objets qui dégagent aussi de la chaleur et qui par conséquent peuvent entraîner le déclenchement intempestif du capteur Piscine Appareil de climatisation Évent de sécheuse Animaux en cage Évent de ventilation Circulation automobile Si vous croyez qu une source de ...

Страница 11: ... de la pile FICHE TECHNIQUE Portée Jusqu à 18 3 m 60 pi Varie selon la température ambiante Angle de détection Jusqu à 110 Ampoule 15 W 6 V à halogène Type de pile Scellée au plomb acide 6V 6 0 AH Durée de fonctionnement 30 secondes redéclenchable Durée de fonctionnement à pleine charge Jusqu à 1 heure REMPLACEMENT DE LA PILE Celuminaireàénergiesolairecomporteunepilerechargea ble qui peut être rem...

Страница 12: ...our est activée 5 Mauvaise orientation 1 Placer le commutateur en position OFF et attendre que la pile se recharge pendant au moins 3 jours ensoleillés consécutifs avant d utiliser à nouveau l appareil 2 Placer le commutateur en position ON 3 Vérifier l ampoule et la remplacer si elle est grillée 4 Essayer de nouveau après la tombée de la nuit 5 Orienter de nouveau le capteur pour couvrir la zone ...

Отзывы: