6
To see operational and troubleshooting information and videos,
go to www.hzsupport.com
210008-02
TROUBLESHOOTING GUIDE
SYMPTOM
POSSIBLE CAUSE
SOLUTION
The light will not come on. 1. Light switch is turned off.
2. Fuse is blown or circuit breaker is turned off.
3. Daylight turn-off (photocell) is in effect.
4. The circuit wiring is incorrect, if this is a new
installation.
5. The motion sensor is aimed in the wrong
direction.
6. The outside air temperature is close to the
same as a person’s body heat.
1. Turn light switch on.
2. Replace fuse or turn circuit breaker on.
3. Recheck after dark.
4. Verify wiring is correct.
5. Re-aim the motion sensor to cover the
desired area.
6. Increase the “SENS” setting. See
Seasonal
Changes
on page 5 for more information.
The light comes on during
the day.
1. The motion sensor may be installed in a
relatively dark location.
2. The “ON-TIME” switch is in the “TEST”
position.
1. The light fixture is operating normally under
these circumstances.
2. Set the “ON-TIME” switch to the 1, 5, or 20
minute setting.
MANUAL MODE
Manual mode overrides the motion sensor and “ON-TIME”
control so the light will operate full bright. This feature only
works at night and only for one night at a time. The motion
sensor will reset to motion sensing mode after 6 hours or
sunrise, whichever comes first. Manual mode can be toggled
on and off using a wall switch.
Note:
If the power to the
light fixture is off for more than 5 seconds, allow the mo-
tion sensor to warm up prior to switching to manual mode.
• Ensure the power to the light is ON and the sensor has
warmed up (60 seconds).
• To turn manual mode on, switch the power OFF–ON–OFF–ON at the wall switch within 3 seconds.
• To turn manual mode off, switch the power OFF–ON–OFF–ON at the wall switch within 3 seconds.
IMPORTANT:
If manual mode does not turn ON or OFF, use a slower pace turning the power ON and OFF at the wall
switch while staying within 3 seconds.
SPECIFICATIONS
Range ...................................................Up to 70 ft. (21 m) [varies with surrounding temperature].
Sensing Angle.......................................Up to 240°
Power Requirements .............................120 VAC, 60 Hz
Electrical load .......................................34 Watts
Operating Modes .................................TEST, MOTION ACTIVATED, and MANUAL MODE
ON-Timer ............................................1, 5, 20 minutes
Test Timer ............................................5 Seconds
Manual Mode Timer ............................Maximum 6 Hours
Sensitivity (SENS) ...............................“L”, “M”, “H”
LED Lumens .......................................2600
OFF
OFF
ON
ON
Less than 3 seconds