Heatcom HC71 Скачать руководство пользователя страница 9

 

 

Event schedule (this is an Auto only menu) 

 

 

 

 

 

 

 

 

7:

    Allows you to choose individual programs for each day of a week. 

        4 events- wake, leave, return, sleep for each day. 

 

2:

    Monday to Friday with the same events setting and Saturday and Sunday with the same setting. Typically used if 

        you work from Monday to Friday. 

        4 events- wake, leave, return, sleep for Monday to Friday, 2 events- wake, sleep for Saturday and Sunday 

 

1:   

7 days of a week programs respectively. 

        2 events- wake, sleep for each day 

 

Program Setting: (this is an Auto only menu) 

 

 

1. Press the OK button to activate the Program setting. 

2. Choose the days for which you want to change the Settings, Mon-Fri or Sat-Sun using the up or down Button. 

    Press OK. 

3. Now select the time and temperature for each daily event in the program. Press OK and set the start time for the 

    event concerned. Confirm with OK. Set the temperature for this event and confirm with OK.   

4. After setting the required events, select Exit in the menu to return to the initial display. 

(Each icon for events programming

Wake

Leave

Return

Sleep

7

 

7 days 

Wake

 

Leave

 

Return

 

Sleep

 

Time 

Temp. 

Time 

Temp. 

Time 

Temp. 

Time 

Temp. 

4 events 

6:30 

22

 

7:30 

19

 

17:00 

22

 

23:00 

18

 

 

2

 

Monday   

to Friday 

Wake

 

Leave

 

Return

 

Sleep

 

Time 

Temp. 

Time 

Temp. 

Time 

Temp. 

Time 

Temp. 

Содержание HC71

Страница 1: ...e underfloor heating without being influenced by other heat sources in the room Power Regulator run in 12 minute cycles The user set how many minutes out of the 12 minute cycle the heating element is...

Страница 2: ...e Floor temperature limiter Yes high and low adjustable IP class IP21 Terminals Max 2 5 mm2 Floor sensor with 3 5m cable NTC 10 K 25 Dimensions 82 mm 82 mm 56 mm Colors Polar white RAL 9010 Signal whi...

Страница 3: ...Enter hour minute weekday and load if load is known Press OK to activate Power Regulator mode If floor sensor is installed set LIMIT FLOOR TEMP TO MAX temperature Default temperature limit setting is...

Страница 4: ...eturn Temp or All Leave and Sleep Temp Then set the desired temperature and press OK Press OK to acknowledge Now all temperatures in the events chosen are changes to the new temperature to Change from...

Страница 5: ...load if load is known to Change from Power Regulator to Manual mode Press Menu and roll forward til MAN menu window Press OK to activate MAN mode to Change from Power Regulator to Auto mode Press Men...

Страница 6: ...ted select Floor Once you have chosen the required setting press OK You now need to select the actual sensor setting so that the thermostat can take this into account during operation Auto Press OK to...

Страница 7: ...possible to set a temperature in this range in auto and manual mode Press OK to highlight Min temperature Use the up or down button to select the minimum permissible temperature Press OK and select t...

Страница 8: ...o not want the settings to be changed or something Press OK and select YES or NO to set up the child lock Confirm with OK The child lock can be unlocked by pressing two side buttons simultaneously for...

Страница 9: ...ss the OK button to activate the Program setting 2 Choose the days for which you want to change the Settings Mon Fri or Sat Sun using the up or down Button Press OK 3 Now select the time and temperatu...

Страница 10: ...nfirm with OK Adaptive this is an Auto only menu It is ensure that the required temperature has already been reached when you get up in the morning or come home from work After just a few days accordi...

Страница 11: ...should be undertaken with care in order not to damage the sensor Connection of floor sensor Connect the floor sensor to the thermostat as shown on the diagram Position and mounting Important The ther...

Страница 12: ...n remove the frame Connect wires and sensors in accordance with the diagram Connection must be made by an authorised electrician Important Always read and follow the instructions for the Underfloor He...

Отзывы: