Heatcom HC71 Скачать руководство пользователя страница 5

 

 

 

Power Regulator mode menu.

 

Use the arrow buttons to run forward or backwards in the Menu sequence. 

If more information to the specific menus are needed, please see Thermostat setup options page 4.   

 

Power Regulator Main Window    Menu start 

     

 

     

Menu end. 

 

 

Press OK to activate Auto mode. Enter hour, minute, weekday and load(if load is known). 

 

 

  to 

 

    Change from Power Regulator to Manual mode.     

 

Press Menu and roll forward til MAN menu window. 

 

Press OK to activate MAN mode. 

 

  to 

 

  Change from Power Regulator to Auto mode.     

 

Press Menu and roll forward til Auto menu window. 

 
Note: If load setting is not correct, only energy consumption readout in the “Energy Monitor” Menu will not show the 

correct consumption. All other functions will work correct and unaffected no matter the load value. 

“To return to Main Window, go to 
EXIT and press OK

 

 

 

25 % 

Содержание HC71

Страница 1: ...e underfloor heating without being influenced by other heat sources in the room Power Regulator run in 12 minute cycles The user set how many minutes out of the 12 minute cycle the heating element is...

Страница 2: ...e Floor temperature limiter Yes high and low adjustable IP class IP21 Terminals Max 2 5 mm2 Floor sensor with 3 5m cable NTC 10 K 25 Dimensions 82 mm 82 mm 56 mm Colors Polar white RAL 9010 Signal whi...

Страница 3: ...Enter hour minute weekday and load if load is known Press OK to activate Power Regulator mode If floor sensor is installed set LIMIT FLOOR TEMP TO MAX temperature Default temperature limit setting is...

Страница 4: ...eturn Temp or All Leave and Sleep Temp Then set the desired temperature and press OK Press OK to acknowledge Now all temperatures in the events chosen are changes to the new temperature to Change from...

Страница 5: ...load if load is known to Change from Power Regulator to Manual mode Press Menu and roll forward til MAN menu window Press OK to activate MAN mode to Change from Power Regulator to Auto mode Press Men...

Страница 6: ...ted select Floor Once you have chosen the required setting press OK You now need to select the actual sensor setting so that the thermostat can take this into account during operation Auto Press OK to...

Страница 7: ...possible to set a temperature in this range in auto and manual mode Press OK to highlight Min temperature Use the up or down button to select the minimum permissible temperature Press OK and select t...

Страница 8: ...o not want the settings to be changed or something Press OK and select YES or NO to set up the child lock Confirm with OK The child lock can be unlocked by pressing two side buttons simultaneously for...

Страница 9: ...ss the OK button to activate the Program setting 2 Choose the days for which you want to change the Settings Mon Fri or Sat Sun using the up or down Button Press OK 3 Now select the time and temperatu...

Страница 10: ...nfirm with OK Adaptive this is an Auto only menu It is ensure that the required temperature has already been reached when you get up in the morning or come home from work After just a few days accordi...

Страница 11: ...should be undertaken with care in order not to damage the sensor Connection of floor sensor Connect the floor sensor to the thermostat as shown on the diagram Position and mounting Important The ther...

Страница 12: ...n remove the frame Connect wires and sensors in accordance with the diagram Connection must be made by an authorised electrician Important Always read and follow the instructions for the Underfloor He...

Отзывы: