A. Chimney Requirements
Vertical distances are measured from the base of the
fi
re-
place as shown in Figure 5.2.
To determine the chimney components needed to complete
your particular installation, follow the steps below:
• Determine the total vertical height of the fireplace
installation. This dimension is measured from the base of
the
fi
replace assembly to the point where the smoke exits
the termination cap.
• Subtract the effective height of the
fi
replace assembly from
the overall height of the
fi
replace installation (measured
from the base of the fireplace to the bottom of the
termination cap).
• Refer to Table 5.1 to determine what components must
be selected to complete the
fi
replace installation.
• Determine the number of ceiling
fi
restops, stabilizers,
roof flashing, etc. required to complete the fireplace
installation.
6 ft (1.8 m) max.
unsupported
run
20 ft (6.10 m) max.
pipe between an
offset & return
Ceiling Firestop
35 ft (10.7 m)
max. straight
unsupported
chimney height
13.25 ft (4.04 m) min. height/single offset-return
20 ft. (6.10 m) min. height/double offset-return
90 ft (27.4 m) max. height
6 ft (1.83 m) max.
unsupported chimney
above roof
44 in.
(1118 mm)
Effective
Height
Figure 5.2 Chimney Requirements
Table 5.1
• Do NOT connect this fireplace to a chimney flue
servicing another appliance.
• Do NOT connect to any air distribution duct or
system.
CAUTION
Fire Risk
• Must maintain 2 in. (51 mm) air clearance
to insulation and other combustible
materials.
WARNING
• Minimum overall straight height
14
(4.27 m)
• Minimum height with offset/return
16.5 ft
(5.03 m)
• Maximum height
90 ft
(27.43 m)
• Maximum chimney length between an offset
and return
20 ft
(6.1 m)
• Maximum distance between chimney
stabilizers
35 ft
(10.67 m)
• Double offset/return minimum height
20 ft
(6.1 m)
• Maximum unsupported chimney length
between the offset and return
6 ft
(1.83 m)
• Maximum unsupported chimney height above
the
fi
replace
35 ft
(10.67 m)
• Maximum unsupported chimney above roof
6 ft
(1.83 m)
Note:
A maximum of two pairs of offsets and returns may
be used.
HEIGHT OF CHIMNEY COMPONENTS
in.
mm
Chimney Stabilizer
SL11
4-3/4
121
Ceiling Firestops
FS538
0
0
FS540
0
0
Offsets/Returns
SL1130
18
457
Roof Flashing
RF570
0
0
RF571
0
0
Chimney Sections*
SL1106
4-3/4
121
SL1112
10-3/4
273
SL1118
16-3/4
425
SL1136
34-3/4
883
SL1148
46-3/4
1187
* Dimensions re