![Heat&Glo 6000CL-IPI-S Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/heatandglo/6000cl-ipi-s/6000cl-ipi-s_owners-manual_2116039027.webp)
27
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. X • 4/14
8000CL
V
1
Minimum
H
1
+ H
2
Maximum
Elbow only
Not allowed
6 in.
152 mm
Not allowed
1 ft.
305 mm
2 ft.
610 mm
1.5 ft.
457 mm
6 ft.
1.8 m
2 ft.
610 mm
11 ft.
3.4 m
2.5 ft.
762 mm
18 ft.
5.5 m
3 ft.
914 mm
24 ft.
7.3 m
V
1
+ H
1
+ H
2
= 40 ft. (12.2 m) Maximum
H
1
+ H
2
= 24 ft. (7.3 m) Maximum
V
1
= 1 ft. (305 mm) Minimum
Note:
For corner installations: A 6 inch
(152 mm) section of straight pipe may
need to be attached to the appliance
before a 90º
elbow, to allow the vent
pipe to clear the top standoffs.
Two Elbows
6
000CL
V
1
Minimum
H
1
+ H
2
Maximum
Elbow only
1 ft.
305 mm
6 in.
152 mm
4 ft.
1.2 m
1 ft.
305 mm
11 ft.
3.4 mm
1.5 ft.
457 mm
18 ft.
5.5 m
2 ft.
610 mm
24 ft.
7.3 m
V
1
+ H
1
+ H
2
= 40 ft. (12.2 m) Maximum
H
1
+ H
2
= 24 ft. (7.3 m) Maximum
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
i u e