Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. X • 4/14
22
D. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances as speci
fi
ed. Framing or
fi
nishing material closer than
the minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc).
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
5
10
11
12
2-1/2
13
14
15
16
17
18
19
32
TO CEILING
9
10
11
12
8
7
6
5
4
3
25
18
A
B
INTERIOR WALL
TOP VIEW
MANTEL LEG OR WALL PROJECTIONS
FIREPLACE OPENING
Note:
All measurements in inches.
If
A
minimum is ____, then
B
maximum is_____.
A
Inches
2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16
Millimeters
62
87
113
138
164
189
B
Inches
1
2
3
4
5
Millimeters
25
51
76
102
127
Note:
Measurement is taken from top of the
opening, NOT the top of the
fi
replace.
Figure 5.4 Clearances to Mantel Legs or Wall Projections
(Acceptable on both sides of opening.)
Figure 5.3 Minimum Vertical and Maximum Horizontal
Dimensions
Mantels - Combustible or Painted Surfaces
Mantel Legs or Wall Projections - Combustible or
Painted Surfaces