![Heat Wagon VG1000 Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/heat-wagon/vg1000/vg1000_installation-and-maintenance-manual_2116014004.webp)
SAFETY & CAUTION
• Instructions given in this manual and the applicable regulation of the local authorities
must be followed.
• The unit may be operated only by those persons who have been instructed in its proper use.
• The unit is to be installed and operated in such a way as to ensure the safety of employees and
surroundings.
• Never cover the unit’s air openings.
• Always ensure adequate fresh air supply to the unit.
• Never stand in front of the discharge end of the heater.
• Keep a minimum clearance of 10 feet from the fuel source. Storing and use of liquid fuel must
comply with the regulation and instructions given by the local authorities.
• Unit’s emitted noise level at the range of 3 feet: 74 dBA.
• Do not introduce foreign objects into the unit.
• Do not expose the unit to direct water jets.
• All electric cables outside the unit are to be protected against damage.
• Always disconnect the unit from power supply and turn off the gas supply when maintenance
or service is being performed.
•
IF NOT OPERATED WITHIN GUIDELINES OF THESE OPERATING INSTRUCTIONS,
MANUFACTURER WILL NOT BE HELD RESPONSIBLE AND WARRANTY
WILL BECOME VOID
.
4
SPECIFICATIONS
Model No. VG1000
Fuels: Vapor Propane or Natural Gas
Gas Inlet 1-1/4” FNPT (Both Wayne & Midco Burner)
Capacity: 1,000,000 BTU/HR
Blower: 4,075 CFM
5.0HP
2.0”SP
Electrical Rating: 240 Volts, 1
Ø
30 Amps
Fuel Consumption: NG-1000 CFH / Propane-11 GPH
Remote Thermostat: On/Off
Max. Discharge Temp.: 200ºF @ 0ºF Ambient
Duct Size: 20” Dia., 200 ft. max (straight)
Shp. Dimensions: 120”L x 31.5”W x 54”H
Weight (approximate):
1,300 lbs.
Gas Supply:
Inlet Pressure Manifold Pressure Pilot Orifice
Midco Burner Max W.C. Min W.C. W.C.
Vapor Propane 14” W.C. 9” W.C. 2.6” .046
Natural Gas 14” W.C. 9” W.C. 4.1” .052
Wayne Burner Max W.C. Min W.C. W.C.
Vapor Propane 14” W.C. 9” W.C. 3.0” N/A
Natural Gas 14” W.C. 9” W.C. 4.6” N/A
Содержание VG1000
Страница 18: ...WAYNE BURNER PARTS BREAKDOWN 18 ...
Страница 20: ...20 WAYNE BURNER SERVICING ELECTRODE SETTING ...
Страница 21: ...21 WAYNE BURNER SERVICING ...
Страница 23: ...23 MIDCO BURNER VG1000 ...
Страница 24: ...24 WAYNE BURNER Serial No M5659 Lower WAYNE BURNER Serial No M5895 Beyond ...
Страница 25: ...MIDCO BURNER VG1000 25 ...
Страница 26: ...26 CONTROL BOX MAIN CIRCUIT DIAGRAM CONTROL BOX WIRING DIAGRAM ...
Страница 27: ...27 CONTROL BOX WIRING ...
Страница 28: ...28 CONTROL BOX PARTS HWP210080 20 HWP 22211 Aux Contact 20 HWP 20582 ...