background image

Always disconnect the heater from the LP cylinder before putting
the heater into storage. If for any reason the heater is to be
stored indoors, the tank MUST be disconnected from the LP
cylinder, and the cylinder stored outdoors in a well-ventilated
area, out of the reach of children, and in accordance with the
Standard for Storage and Handling of Liquefied Gases,
ANSI/NFPA 58 - latest edition and Natural Gas and Propane
Installation Code, CSA 149.1. The plastic valve plug or valve
cover supplied with the cylinder must be re-installed on the valve
to protect the fitting from damage.

Never store an LP cylinder inside of a
building, or near any other gas or oil

burning appliances.

NOTE: Installation and repair of this heater should be done
by a qualified service person.

Always be sure to follow proper maintenance procedures. This
should include cleaning the inside the heater once a month, and
checking the spark gap at least once a heating season.

TO START

1. Connect power cord to a properly grounded three (3) prong

120V, 60 Hz, extension cord.

Extension Cord Wire Requirements: 
6 to 10 feet (1.8 to 3 meters) long, use 18 AWG conductor.

11 to 100 feet (3.4 to 30.53 meters) long, use 16 AWG 
conductor.

101 to 200 feet (30.8 to 61 meters) long, use 14 AWG 
conductor.

2. Connect heater to a proper LP cylinder.

3. Turn gas valve clockwise to OFF position.

4. Wait five (5) minutes for any gas to clear. Smell for gas; if you

do not smell gas, go to Step 4.

5. Push in and turn gas control knob counterclockwise to

LOW/IGN position. This will light the burner. If needed, keep
pressing control knob until the burner lights and keep pressing
and turning from OFF to LOW/ IGN on Piezo electric spark
models (HIGH/IGN on Model HS-40-GFA).

6. Keep the valve knob depressed for at least 30 seconds after

lighting the burner. After 30 seconds, release valve knob.

7. If burner does not stay lit, repeat lighting procedure.

8. When burner stays lit, turn gas valve knob counterclockwise to

desired setting (All models except HS-40-GFA)

.

SHUTDOWN INSTRUCTIONS

To shut off heater:

1. Turn gas valve knob clockwise to OFF position.

2. Turn gas supply OFF by turning LP cylinder valve clockwise to

close.

3. Disconnect the power cord.

TEST FIRING THE HEATER

Test fire your construction heater following the lighting instruc-
tions applicable to the gas control system employed.

Leak test all gas connections with 50/50 soap and water solution
prior to start-up. Soap bubbles indicate a gas leak. DO NOT use
a match or flame to test for gas leaks.

NOTE:

Heater surface temperature must be cold before initiating

service, cleaning or storage.

© 2012, Pinnacle Products International, Inc.

6

Propane Forced Air User’s Manual

Ventilation

Always provide a fresh air opening in the

heated space of at least three square feet

(2,800 sq. cm.) for each 100,000 BTU/Hr of heater output.  For
example, a HS-150V-GFA will require:

- a two-car garage door open 6 inches, or

- a single car garage open 9 inches, or

- two thirty two inch wide windows open 15 inches.

CAUTION

Lighting Instructions

Storage / Maintenance

DANGER

NEVER LEAVE HEATER UNATTENDED

WHILE BURNING, CONNECTED TO A

POWER SOURCE, OR WHILE

CONNECTED TO A FUEL SOURCE

Содержание HS-125V-GFA

Страница 1: ... OF FIRE EXPLOSION BURN ASPHYXIATION CARBON MONOXIDE POISONING AND OR ELECTRIC SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABEL ETC CONTACT THE MANUFACTURER Carbon Monoxide Hazard This heater produces carbon monoxide which has no odor Burning the heater in an enclose...

Страница 2: ...this manual and attached to the unit are therefore not all inclusive If a procedure work method or operating technique not specifically recommended by Pinnacle is used you must be sure it is safe for you and others You should also insure that equipment will not be damaged or made unsafe by the operating or maintenance method you choose If the information in this manual is not followed exactly a fi...

Страница 3: ...lectrical power cord specified Electrical and grounding connection must comply with National Electrical Code ANSI NFPA 70 USA and CSA C22 1 Canadian Electrical Code Part 1 Canada To prevent injury always wear gloves when handling heater Never handle an operating or hot heater as severe burns may result Use heater in accordance with all local codes In the absence of local codes refer to The Nationa...

Страница 4: ...ted on a level and stable sur face Do not use this heater in a basement or below ground level Propane LP is heavier than air and will always seek the low est level If you suspect a leak shut off the valve at the LP cylinder immediately The Propane LP cylinder must also be equipped with the following A collar to protect the gas valve A shut off valve terminating a LP cylinder valve outlet as specif...

Страница 5: ... heater gas valve knob and LP cylinder valve to OFF position LP cylinder valve equipped with old style fitting has LEFT HANDED THREADS Turn fitting CLOCKWISE to loosen Protect this fitting when disconnected from LP cylinder Have your LP cylinder filled by your local Propane gas supplier Some LP cylinders have a bleed off valve This valve should be inspected for leaks after each filling of the LP c...

Страница 6: ...b counterclockwise to LOW IGN position This will light the burner If needed keep pressing control knob until the burner lights and keep pressing and turning from OFF to LOW IGN on Piezo electric spark models HIGH IGN on Model HS 40 GFA 6 Keep the valve knob depressed for at least 30 seconds after lighting the burner After 30 seconds release valve knob 7 If burner does not stay lit repeat lighting ...

Страница 7: ...re or its equivalent except as indicated Figure 5 Wiring Diagram for Piezo Manual Spark Models Figure 6 Wiring Diagram for Continuous Spark Models NOTE If any original wiring as supplied with the heater must be replaced it must be with type AWG 105 C wire or its equivalent except as indicated NEVER LEAVE HEATER UNATTENDED WHILE BURNING CONNECTED TO A POWER SOURCE OR WHILE CONNECTED TO A FUEL SOURC...

Страница 8: ...ced Air User s Manual 1 2 6 7 8 12 13 14 15 16 17 25 20 23 22 19 5 28 27 4 24 3 9 11 10 18 21 26 Exploded View Figure 7 Exploded View for all models NEVER LEAVE HEATER UNATTENDED WHILE BURNING CONNECTED TO A POWER SOURCE OR WHILE CONNECTED TO A FUEL SOURCE ...

Страница 9: ...22 514 0001 22 514 0002 22 514 0002 1 15 Cushion Pad 22 509 0001 22 509 0001 22 509 0001 22 509 0001 1 16 Motor Assembly 22 061 0015 22 061 0015 22 061 0016 22 061 0016 1 17 Guard 22 101 0003 22 101 0003 22 101 0004 22 101 0004 1 18 Round Bolt 22 503 0002 22 503 0002 22 503 0003 22 503 0003 1 19 Valve Assembly 22 011 0005 22 011 0017 22 011 0018 22 011 0008 1 20 Inlet Connector 22 507 0003 22 507 ...

Страница 10: ...park gap 3 Corroded electrode 1 Inspect module wire Re attach or tighten if loose Inspect Spark module and replace if necessary Inspect all other electrical components 2 Set plug gap to 0 16 4mm 3 Replace spark plug Multi Bracket Assembly Heater stops running by itself 1 Temperature inside heater is too high causing thermal switch to shut down operation 2 Damaged control valve 3 Dust or debris acc...

Страница 11: ...nc will repair or replace and return the item freight pre paid If Pinnacle Products International Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle Products International Inc disclaims all warranties for products that are purchased from sellers other than author...