background image

© 2012, Pinnacle Products International, Inc.

10

Propane Forced Air User’s Manual

Troubleshooting

Fan does not turn when

electricity is connected

1. No electric power to heater.

2. Blades of fan in contact with heater 

housing.

3. Fan blades bent.

4. Fan motor defective.

1. Check current at outlet. If voltage is correct,

inspect extension and power cords for cuts,
frays or breaks.

2. Check housing for damage. Be sure there

are no dents in the housing obstructing the
fan.

3. Straighten all fan blades.

4. Replace Motor Assembly.

Heater will not fire (ignite)

1. No spark at module.

2. Incorrect spark gap.

3. Corroded electrode.

1. Inspect module wire. Re-attach, or tighten if

loose. Inspect Spark module, and replace if
necessary. Inspect all other electrical 
components.

2. Set plug gap to 0.16” (4mm).

3. Replace spark plug (Multi-Bracket

Assembly).

Heater stops running by

itself

1. Temperature inside heater is too high,

causing thermal switch to shut down 
operation.

2. Damaged control valve.

3. Dust or debris accumulated in heater.

1. If heater input or output is restricted, the

inside temperature can become too hot.
Keep the areas in front and behind heater
clear of obstructions.

2. Replace control valve (Valve Assembly).

3. Clean inside of heater.

Symptom

Possible Cause(s)

Solution

NEVER LEAVE HEATER UNATTENDED

WHILE BURNING, CONNECTED TO A

POWER SOURCE, OR WHILE

CONNECTED TO A FUEL SOURCE

Содержание HS-125V-GFA

Страница 1: ... OF FIRE EXPLOSION BURN ASPHYXIATION CARBON MONOXIDE POISONING AND OR ELECTRIC SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABEL ETC CONTACT THE MANUFACTURER Carbon Monoxide Hazard This heater produces carbon monoxide which has no odor Burning the heater in an enclose...

Страница 2: ...this manual and attached to the unit are therefore not all inclusive If a procedure work method or operating technique not specifically recommended by Pinnacle is used you must be sure it is safe for you and others You should also insure that equipment will not be damaged or made unsafe by the operating or maintenance method you choose If the information in this manual is not followed exactly a fi...

Страница 3: ...lectrical power cord specified Electrical and grounding connection must comply with National Electrical Code ANSI NFPA 70 USA and CSA C22 1 Canadian Electrical Code Part 1 Canada To prevent injury always wear gloves when handling heater Never handle an operating or hot heater as severe burns may result Use heater in accordance with all local codes In the absence of local codes refer to The Nationa...

Страница 4: ...ted on a level and stable sur face Do not use this heater in a basement or below ground level Propane LP is heavier than air and will always seek the low est level If you suspect a leak shut off the valve at the LP cylinder immediately The Propane LP cylinder must also be equipped with the following A collar to protect the gas valve A shut off valve terminating a LP cylinder valve outlet as specif...

Страница 5: ... heater gas valve knob and LP cylinder valve to OFF position LP cylinder valve equipped with old style fitting has LEFT HANDED THREADS Turn fitting CLOCKWISE to loosen Protect this fitting when disconnected from LP cylinder Have your LP cylinder filled by your local Propane gas supplier Some LP cylinders have a bleed off valve This valve should be inspected for leaks after each filling of the LP c...

Страница 6: ...b counterclockwise to LOW IGN position This will light the burner If needed keep pressing control knob until the burner lights and keep pressing and turning from OFF to LOW IGN on Piezo electric spark models HIGH IGN on Model HS 40 GFA 6 Keep the valve knob depressed for at least 30 seconds after lighting the burner After 30 seconds release valve knob 7 If burner does not stay lit repeat lighting ...

Страница 7: ...re or its equivalent except as indicated Figure 5 Wiring Diagram for Piezo Manual Spark Models Figure 6 Wiring Diagram for Continuous Spark Models NOTE If any original wiring as supplied with the heater must be replaced it must be with type AWG 105 C wire or its equivalent except as indicated NEVER LEAVE HEATER UNATTENDED WHILE BURNING CONNECTED TO A POWER SOURCE OR WHILE CONNECTED TO A FUEL SOURC...

Страница 8: ...ced Air User s Manual 1 2 6 7 8 12 13 14 15 16 17 25 20 23 22 19 5 28 27 4 24 3 9 11 10 18 21 26 Exploded View Figure 7 Exploded View for all models NEVER LEAVE HEATER UNATTENDED WHILE BURNING CONNECTED TO A POWER SOURCE OR WHILE CONNECTED TO A FUEL SOURCE ...

Страница 9: ...22 514 0001 22 514 0002 22 514 0002 1 15 Cushion Pad 22 509 0001 22 509 0001 22 509 0001 22 509 0001 1 16 Motor Assembly 22 061 0015 22 061 0015 22 061 0016 22 061 0016 1 17 Guard 22 101 0003 22 101 0003 22 101 0004 22 101 0004 1 18 Round Bolt 22 503 0002 22 503 0002 22 503 0003 22 503 0003 1 19 Valve Assembly 22 011 0005 22 011 0017 22 011 0018 22 011 0008 1 20 Inlet Connector 22 507 0003 22 507 ...

Страница 10: ...park gap 3 Corroded electrode 1 Inspect module wire Re attach or tighten if loose Inspect Spark module and replace if necessary Inspect all other electrical components 2 Set plug gap to 0 16 4mm 3 Replace spark plug Multi Bracket Assembly Heater stops running by itself 1 Temperature inside heater is too high causing thermal switch to shut down operation 2 Damaged control valve 3 Dust or debris acc...

Страница 11: ...nc will repair or replace and return the item freight pre paid If Pinnacle Products International Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle Products International Inc disclaims all warranties for products that are purchased from sellers other than author...

Отзывы: