21
Figure 17. Venting with Two 90° Elbows - TR MODELS
MODEL SL-550TR
V (MIN.)
H (MAX.)
90
o
Elbow on Top
2.5 FT (863mm)
1 FT (305mm)
3 FT (914mm)
2 FT (610mm)
4 FT (1.22m)
3 FT (914mm)
6 FT (1.86m)
4 FT (1.22m)
8 FT (2.48m)
5 FT (1.52m)
16 FT (4.8m)
VENTING WITH TWO (2) 90
o
ELBOWS NATURAL GAS
H MAX. = 16 FT (4.8m) V + V
1
+ H MAX. = 40 FT (12.2m)
MODEL SL-750TR
MODEL SL-950TR
H (MAX.)
H (MAX.)
2.5 FT (863mm)
2 FT (610mm)
3 FT (914mm)
3 FT (914mm)
4 FT (1.22m)
4 FT (1.22m)
6 FT (1.86m)
6 FT (1.86m)
8 FT (2.48m)
8 FT (2.48m)
16 FT (4.8m)
16 FT (4.8m)
MODEL SL-550TR
V (MIN.)
H (MAX.)
90
o
Elbow on Top
2.5 FT (863mm)
1 FT (305mm)
2.5 FT (863mm)
2 FT (610mm)
4 FT (1.22m)
3 FT (914mm)
6 FT (1.86m)
4 FT (1.22m)
8 FT (2.48m)
5 FT (1.52m)
16 FT (4.8m)
VENTING WITH TWO (2) 90
o
ELBOWS PROPANE
H MAX. = 16 FT (4.8m) V + V
1
+ H MAX. = 40 FT (12.2m)
MODEL SL-750TR
MODEL SL-950TR
H (MAX.)
H (MAX.)
NOT ALLOWED
NOT ALLOWED
2 FT (610mm)
2 FT (610mm)
4 FT (1.22m)
4 FT (1.22m)
6 FT (1.86m)
6 FT (1.86m)
8 FT (2.48m)
8 FT (2.48m)
16 FT (4.8m)
16 FT (4.8m)
Use SL D-Series
components only.
Содержание SL-550TR
Страница 8: ...5 Figure 1 Diagram of the SL 950TR ...
Страница 9: ...6 Figure 2 Diagram of the SL 750TR and SL 750TRS ...
Страница 10: ...7 Figure 3 Diagram of the SL 550TR and SL 550TRS ...
Страница 15: ...12 Figure 8 SL D Series Direct Vent Component Specifications 4 inch inner pipe 6 5 8 inch outer pipe ...