Figure 12. Venting with One 90° Elbow - TR MODELS
MODEL SL-550TR
V (MIN.)
H (MAX.)
90
o
Elbow on Top
2.5 FT (863mm)
1 FT (305mm)
3 FT (914mm)
2 FT (610mm)
4 FT (1.22m)
3 FT (914mm)
6 FT (1.86m)
4 FT (1.22m)
8 FT (2.48m)
5 FT (1.52m)
16 FT (4.8m)
Use SL D-Series
components only.
VENTING WITH ONE (1) 90
o
ELBOW NATURAL GAS
H MAX. = 16 FT (4.8m)
V + H MAX. = 40 FT (12.2m)
MODEL SL-750TR
MODEL SL-950TR
H (MAX.)
H (MAX.)
2.5 FT (863mm)
2 FT (610mm)
3 FT (914mm)
3 FT (914mm)
4 FT (1.22m)
4 FT (1.22m)
6 FT (1.86m)
6 FT (1.86m)
8 FT (2.48m)
8 FT (2.48m)
16 FT (4.8m)
16 FT (4.8m)
MODEL SL-550TR
V (MIN.)
H (MAX.)
90
o
Elbow on Top
2.5 FT (863mm)
1 FT (305mm)
2.5 FT (863mm)
2 FT (610mm)
4 FT (1.22m)
3 FT (914mm)
6 FT (1.86m)
4 FT (1.22m)
8 FT (2.48m)
5 FT (1.52m)
16 FT (4.8m)
VENTING WITH ONE (1) 90
o
ELBOW PROPANE
H MAX. = 16 FT (4.8m)
V + H MAX. = 40 FT (12.2m)
MODEL SL-750TR
MODEL SL-950TR
H (MAX.)
H (MAX.)
NOT ALLOWED
NOT ALLOWED
2 FT (610mm)
2 FT (610mm)
4 FT (1.22m)
4 FT (1.22m)
6 FT (1.86m)
6 FT (1.86m)
8 FT (2.48m)
8 FT (2.48m)
16 FT (4.8m)
16 FT (4.8m)