RHW-44 WOODBURNING FIREPLACE

WARNING!

FIREPLACES EQUIPPED WITH

DOORS SHOULD BE OPERATED

ONLY WITH DOORS FULLY OPEN OR

FULLY CLOSED.  IF DOORS ARE

LEFT PARTIALLY OPEN, GAS AND

FLAME MAY BE DRAWN OUT OF THE

FIREPLACE OPENING, CREATING

THE RISK OF BOTH FIRE AND

SMOKE.

WARNING!

CONTINUED OVER-FIRING CAN PER-
MANENTLY DAMAGE YOUR FIRE-
PLACE SYSTEM.  EXAMPLES OF
OVER-FIRING ARE:

1.

THE

“NORMAL

LOG

FIRE”

SHOULD BE CONTAINED IN THE
GRATE, WITH THE LENGTH OF
LOGS NO GREATER THAN THE
BACK WALL OF THE FIREPLACE.

2.

THE FOLLOWING MATERIALS

MUST NOT BE USED IN THIS FIRE-
PLACE: QUANTITIES OF SCRAP
LUMBER,

PINE

BRANCHES,

PROCESSED FIRE LOGS AND FIRE
STARTERS,

OR

CARDBOARD

BOXES WHICH EXCEED THE VOL-
UME OF THE “NORMAL LOG FIRE”.
THESE MATERIALS PRODUCE MANY
SPARKS AND MUST NOT BE USED.

Figure 26

Recommended Operating Positions of Doors

3-00

22                                                                                      33147A

Before starting a fire in your RHW-44 fireplace, use
the following check list:

FLUE DAMPER.

The flue damper is operated by

pushing the handle up toward the top of the fire-
box, which should place the damper in a fully open
position.  Verify this by looking up from the inside
of the firebox.  Always operate this fireplace with
the damper fully open.  Please note, down drafts,
obstructions, damage or poor (wet) fuels can cause
smoke spillage.

CHIMNEY INSPECTION.

Visually inspect the

chimney internally for obstructions and construction
damage.  Flue pipe joints and seams must be con-
tinuous and mechanically tight.  In a used chimney,
additional inspection is needed for creosote build-
up which is the formation of a flammable sediment.

When wood is burned slowly, it produces tar and
other organic vapors, which combine with expelled
moisture to form creosote.  The creosote vapors
condense in the relatively cool chimney flue of a
slow-burning fire.  As a result, creosote residue
accumulates on the flue lining.  When ignited, this
creosote makes an extremely hot fire.

The chimney should be inspected at least twice a
year during the heating season to determine if cre-
osote build-up has occurred.

If creosote has accumulated, it should be removed
to reduce the risk of a chimney fire.

CHIMNEY CLEANING.

If you do detect a build-up

of creosote, contact a qualified chimney sweep or
clean it yourself.  To do this, perform the following
steps:

1.

Open the damper.

2.

Hang a damp sheet across the fireplace
opening to stop dirt and soot from enter-
ing the room.

3.

Remove the Terminal Cap or Housing
Top.  See Figure 27.

4.

Clean with a stiff nylon brush attached to
a pole 

OR

tie a rope to a burlap bag filled

with straw and several small stones or
sand.  Work up and down the flue until
clean.

5.

Replace the terminal cap or housing top.

GLASS DOORS.

Most efficient fireplace operation

using glass doors is with the doors open.  When
the doors are open, the screen must be closed.
Only glass doors, model numbers:  DM1136,
DM1136A, DM1136B, C1136A, C1136B, C1136C,
C2136A, C2136B, C2136C or P1136B may be
used on this fireplace.

Содержание RHW-44

Страница 1: ...ion information Framer Please refer to page 9 for framing specifications RHW 44 WOODBURNING FIREPLACE INSTALLATION OPERATING INSTRUCTIONS FOR RESIDENTIAL USE Heat N Glo a Division of Hearth Technologi...

Страница 2: ...lly tight the optional combustion air kit may not provide all the air required to support combustion Heat N Glo is not responsible for any smoking or related prob lems that may result from the lack of...

Страница 3: ...ITEMS IN THIS SYSTEM UNLESS ALLOWED BY THESE INSTALLATION INSTRUCTIONS WILL VOID THE UNDERWRITERS LABORATORIES LISTING AND MAY VOID THE PRODUCT WARRANTY IT MAY ALSO CREATE A HAZARDOUS INSTALLATION RE...

Страница 4: ...Integral Grate included with Fireplace ID4 Insulated Duct Outside Air UD4 Uninsulated Duct Outside Air CAK4 Chimney Air Kit SL306 Chimney Section 6 long SL312 Chimney Section 12 long SL318 Chimney Se...

Страница 5: ...3 00 5 33147A OUTSIDE AIR KIT SUPPLIED RHW 44 WOODBURNING FIREPLACE AK14 GR8 STRAIGHT ATTIC HEARTH EXTENSION GLASS DOORS INSULATION SHIELD INTEGRAL GRATE HX3 AS8...

Страница 6: ...SL348 48 463 4 CAT A B FS338 0 141 2 FS339 15 183 8 FS340 30 23 CHIMNEY SECTIONS CHIMNEY STABILIZER OFFSETS RETURNS SL3 FIRESTOP SPACERS RF371 6 12 to 12 12 Pitch ROOF FLASHING A Actual length B Effec...

Страница 7: ...HIMNEY TERMINAL CAPS VENT SECTIONS RHW 44 WOODBURNING FIREPLACE CT35 CHASE TOP TS345 345P SQUARE TERMINAL CAP TR342 ROUND TELESCOPING TERMINAL CAP TR344 ROUND TERMINAL CAP WITH STORM COLLAR ST375 SQUA...

Страница 8: ...LACE MUST NOT BE INSTALLED AGAINST VAPOR BARRIERS OR EXPOSED INSULA TION LOCALIZED OVERHEATING COULD OCCUR AND A FIRE COULD RESULT A B C D 783 4 393 8 171 4 555 8 WITH OR WITHOUT OUTSIDE AIR Figure 2...

Страница 9: ...ny material capable of igniting and burning whether flame proofed or not plastered or unplastered Non combustible Material Material which will not ignite and burn Such materials are those consisting e...

Страница 10: ...CALCULATE THE REQUIRED THICKNESS FOR THE ALTERNATE MATERIAL USE THE FOLLOWING FORMULA K ALT 43 EXAMPLES OF INSULATION USG MICORE CV230 1 2 0 43 MINIMUM REQUIRED THICKNESS K VALUE x 5 THICKNESS OF ALT...

Страница 11: ...ey section s may be used between an offset and return However the distance between two elbows must never exceed 10 feet in total length a Measure how far the chimney needs to be shifted to enable it t...

Страница 12: ...losest to but not less than 141 2 is 145 8 using a 30 offset return It is then determined from the table that you would need 33 Dimension B between the offset and return The chimney components that be...

Страница 13: ...eate a need for a taller chimney should smoking occur If the horizontal distance from the side of the chim ney to the peak of the roof is more than 10 feet a chimney height reference point is establis...

Страница 14: ...metal strips two inches under the front edge of the fireplace The individual pieces must overlap each other by one inch in the middle of the fireplace to provide continuous coverage of the floor See...

Страница 15: ...sides of the firestop spacer to the joists using a minimum of three 3 nails per side These firestop spacers are designed to provide the minimum 2 air space required around the chimney In all situation...

Страница 16: ...ave straps for securing these parts to joists or rafters See Figure 15 STEP 11 Cutting out the Hole in the Roof Measure to either side of the nail and mark the 14 1 2 x 14 1 2 opening required This is...

Страница 17: ...t A mini mum clearance of an 1 2 must be maintained between the fireplace sides and the enclosure as well as the fire place back and the enclosure See Figure 4 for framing details NOTE Use only a non...

Страница 18: ...ROPER VENTING OF COMBUS TION PRODUCTS WARNING THIS FIREPLACE WAS NOT TESTED BY THE FIREPLACE MANUFACTURER FOR USE WITH AN UNVENTED GAS LOG HEATER DO NOT INSTALL AN UNVENTED GAS LOG HEATER IN THIS FIRE...

Страница 19: ...the chase several factors must be considered a Maintain an 1 2 minimum air space around the firebox b Maintain a 2 air space around the chimney c The chase top must be constructed of a non combustibl...

Страница 20: ...ntended to operate as a supple mental heat source for a single room It is not designed to function as a primary heat source for a structure Fireplaces as well as other woodburning appliances have been...

Страница 21: ...spillage during start up WARNING DO NOT OPERATE THIS FIREPLACE WITH THE FLUE DAMPER IN THE CLOSED POSI TION COMBUSTION PRODUCTS MUST VENT UP THE CHIMNEY SYSTEM TO PRE VENT CARBON MONOXIDE POISONING AN...

Страница 22: ...n damage Flue pipe joints and seams must be con tinuous and mechanically tight In a used chimney additional inspection is needed for creosote build up which is the formation of a flammable sediment Wh...

Страница 23: ...escreens must not be used to hold burning material inside the fireplace Only those glass door units specifically tested and listed for use with the specific fireplace model should be used Screens shou...

Страница 24: ...ring the first six 6 months after installation HEAT N GLO shall at its option replace or repair the Glass Doors and any electrical components if operation is faulty This does not include Glass panels...

Отзывы: