Installing the Fireplace

Step 1.       Locating the Fireplace

The diagram below shows space and clearance require-

ments for locating a fireplace within a room.

Minimum Clearances

 from the Fireplace to Combustible Materials

Inches

mm

Glass Front ........................ 36 .................... 914

Floor ................................... 0 ....................... 0

Rear ...................................1/2 ..................... 13

Sides .................................1/2 ..................... 13

Top ...................................... 4 ..................... 102

Ceiling* .............................. 50 ....................1270

   Figure 2.    Fireplace Dimensions, Locations,

                     and Space Requirements

Clearance Requirements

The top, back, and sides of the fireplace are defined by

stand-offs. The minimum clearance to a perpendicular wall

extending past the face of the fireplace is one inch (25

mm). The back of the fireplace may be recessed 18 3/4

inches (476 mm) into combustible construction.

Figure 3. Framing Dimensions

The distance from the unit to combustible construction

is to be measured from the unit outer wrap surface to

the combustible construction, 

NOT

 from the screw

heads that secure the unit together.

Minimum Clearances from the Class B Chimney Vent

Pipe to Combustible Materials is 1 inch (25mm) all

around the pipe.

Step 2.  Framing the Fireplace

Fireplace framing can be built before or after the fireplace is

set in place. Framing should be positioned to accommo-

date wall coverings and fireplace facing material. The dia-

gram below shows framing reference dimensions.

CAUTION:

 MEASURE FIREPLACE DIMENSIONS AND

VERIFY FRAMING METHODS AND WALL COVERING

DETAILS BEFORE FRAMING.

* The clearance to the ceiling is measured from the top

of the unit, excluding the standoffs (see Figure 11).

Framing should be

constructed of 2 X 4

lumber or heavier.

A

B

C

D

36 3/4”

35 13/16”

19 3/4”

29 15/16”

NOTE: 

You must place the supplied (required) non-

combustible board on the top front face of the unit once the

unit is in place. See Figure 11.

Содержание CFX-TV36B

Страница 1: ...derwriters Laboratories Listed 592 900F 5 00 READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE THIS INSTALLERS GUIDE MUST BE LEFT WITH APPLIANCE FOR FUTURE REFERENCE Please contact your H...

Страница 2: ...he installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the first firing of the fireplace READ the Using Your Firepla...

Страница 3: ...tem 11 A Vent System Approvals 11 B System Components 11 C Bedroom Installation in Canada 12 D Vent Termination 12 Step 5 Positioning Leveling and Securing the Fireplace 12 Step 6 The Gas Control Syst...

Страница 4: ...FX TV36B DSI NG LP Exploded Parts Diagram Vue clat e des pi ces Part number list on following page La liste des num ros de pi ce se trouve la page suivante 3 4 2 9 7 Log Set Assembly 5 8 13 12 11 10 6...

Страница 5: ...ssembly Jeu de B ches LOGS TV36B 8 Log 1 B che 1 SRV446 701 9 Log 2 B che 2 SRV446 702 10 Log 3 B che 3 SRV446 703 11 Log 4 B che 4 SRV540 704 12 Log 5 B che 5 SRV560 702 13 Log 6 B che 6 SRV446 706 J...

Страница 6: ...es current edition The Uniform Mechanical Code current edition and local Building Officials for the options allowed in obtaining an effective bedroom volume of unconfined space This model natural gas...

Страница 7: ...ese instructions will void the owner s warranty and may present a fire hazard WARNING IF THERE IS ANY NOTICEABLE DAMAGE TO THE FIBER FIREBOX PLEASE CONTACT YOUR DEALER FOR FURTHER INSTRUCTIONS The Hea...

Страница 8: ...8 Figure 1 Diagram of the CFX TV36B...

Страница 9: ...to be measured from the unit outer wrap surface to the combustible construction NOT from the screw heads that secure the unit together Minimum Clearances from the Class B Chimney Vent Pipe to Combust...

Страница 10: ...the structure where the fireplace is located It is recommended that all natural venting non air tight gas fireplaces have outside air connected to them It is also recommended that the building be mech...

Страница 11: ...outlet collar Look at the vent pipe through the holes in the 10 5 8 ring to check that the vent pipe is attached NOTE It is always better to first attach a straight section of vent to the unit before...

Страница 12: ...nt Termination VENT CAP 12 X ROOF PITCH IS X 12 LOWEST DISCHARGE OPENING H MIN MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Step 5 Positioning Leveling and Securing the Fireplace To properly p...

Страница 13: ...hole and connect it to the shut off valve When attaching the pipe support the control so that the lines are not bent or torn After the gas line installation is complete use a soap solution to carefull...

Страница 14: ...nal Accessories Optional remote control kits require that 110 120 VAC be wired to the fireplace junction box WARNING TOAVOID POTENTIAL OVERHEAT ING TO THE REMOTE CONTROL RECEIVER IT MUST BE PLACED ON...

Страница 15: ...aterial Installing the Trim Combustible materials may be brought up to the specified clearances on the side and top front edges of the fireplace but MUST NEVER overlap onto the front face The joints b...

Страница 16: ...ed for faulty components Now you re ready to light the fireplace WARNING PLEASE REFER TO THE USER S MANUAL FORALL CAUTIONS SAFETY AND WARNING INFORMATION PERTAINING TO THE LIGHTING AND OPERATION OF TH...

Страница 17: ...vacuum the control compartment fireplace logs and burner areas surrounding the logs Checking Flame Patterns Flame Height Frequency Periodically By Qualified service technician Home owner Task Make a...

Отзывы: