Heat & Glo  •  COSMO-I30-IFT, COSMO-I35-IFT Installation Manual  •  2535-980 Rev. S  •  12/21 

C.  Zero Clearance Wall Extension

Figure 3.11

 

 Non-Combustible Facing Requirement

Figure 3.10

 

 Non-Combustible Framing Requirement

FLOOR

EXISTING MASONRY WALL

NEW WALL 

FACE

WALL EXTENSION

NON-COMBUSTIBLE ZONE

Figure 3.12  Non-Combustible Framing / Facing Requirement

WARNING! Risk of Fire! 

Comply with all minimum clear-

ances  to  combustibles  as  specified.  Framing  or  finishing 

material closer than the minimums listed must be construct-

ed  entirely  of  noncombustible  materials  (i.e.,  steel  studs, 

concrete board, etc).
Combustible  facings  must  not  extend  behind  the  insert 

surround. See Figure 1.E and 1.F.

Non-Combustible Materials Specification

Material which will not ignite and burn. Such materials are 

those consisting entirely of steel, iron, brick, tile, concrete, 

slate, glass or plasters, or any combination thereof.

Materials that are reported as passing 

ASTM E 136, 

Standard Test Method for Behavior of Materials in a 

Vertical Tube Furnace at 750 ºC.

•  Facing and/or finishing materials must not interfere with 

air flow through decorative barrier fronts.

•  Facing and/or finishing materials must never overhang 

into the glass opening.

• Observe all clearances when applying combustible 

materials.

•  Maximum depth of wall extension is 12 inches.  This 

may be limited by the flex pipe’s ability to connect to the 

starting collar.

•  Covering combustible materials with non-combustible 

materials does not qualify material as non-combustible.

WARNING!  Risk of Fire! DO NOT

  apply  combustible 

materials beyond the minimum clearances. Comply with 

all minimum clearances to combustibles as specified in 

this manual. Overlapping materials could ignite and will 

interfere with proper operation of decorative barrier fronts.

FLOOR

x

Y

NON-COMBUSTIBLE ZONE

CL

EXISTING MASONRY WALL

NEW WALL 

FACE

WALL EXTENSION

FLOOR

x

Y

NON-COMBUSTIBLE ZONE

CL

UNIT X (min)

Y

(min)

30 in. 33-1/2

56

35 in.

36

60

UNIT

(min)

Y

(min)

30 in. 33-1/2

56

35 in.

36

60

12 in. max.

   DEPTH

A non-combustible wall extension can be used to cover 

an existing masonry surface.  Wall extensions are typically 

used to improve cosmetics. 

Surrounds MUST overlap wall extension. 

X -  Minimum - measure from  

       center of firebox opening.

Y -  Minimum - measure from  

       the bottom of the appliance.

X -  Minimum - measure from  

       center of firebox opening.

Y -  Minimum - measure from  

       the bottom of the appliance.

Содержание COSMO-I30-IFT

Страница 1: ...ases unless a certified kit is used DO NOT store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance What to do if you smell gas DO NOT try to light a...

Страница 2: ...nd Clearances A Appliance Decorative Barrier Front Dimension Diagrams 8 B Minimum Fireplace Opening 13 C Zero Clearance Wall Extension 15 D Mantel Wall Projections Hearth Extensions 17 E Hearth Extens...

Страница 3: ...type ___________________________ Was a conversion performed ___________________________ Leak check performed and inlet pressure verified ___________________________ Verified proper air shutter settin...

Страница 4: ...tive appliance It should not be factored as primary heat in residential heating calculations NOTICE This installation must conform with local codes In the absence of local codes you must comply with t...

Страница 5: ...sure chimney is constructed of non combustible materials Ensure chimney is clean and in good working order Ensure that all chimney cleanouts fit properly to prevent air leakage into chimney Ensure com...

Страница 6: ...can be stored in appliance manual bag Multi purpose tool can be stored behind the surround Multi purpose tool can be stored behind the appliance front Multi Purpose Tool Shipping Location Multi Purpos...

Страница 7: ...een under water Call a qualified service technician to inspect the appliance and to replace any part of the control system and or gas control which has been under water C Tools and Supplies Needed Bef...

Страница 8: ...on Figure 3 9 MODEL DIMENSIONS Location 30 in 35 in IN MM IN MM A 19 5 8 499 24 5 8 626 B 31 1 8 791 36 1 8 918 C 27 1 2 699 32 1 2 826 D 15 15 16 405 19 3 8 492 E 20 3 4 527 24 610 F 20 1 8 511 23 5...

Страница 9: ...COSMO I35 IFT INFIT 35 in 32 5 8 19 9 16 1 7 8 35 5 8 24 23 1 2 1 2 mm 829 497 48 905 610 597 13 F D A B C G E NOTICE 1 2 inch gap must be maintained or components will overheat IMPORTANT This firepla...

Страница 10: ...Firescreen DECORATIVE BARRIER FRONTS FIRESCREEN A B C D E F G COSMO I30 IFT FS MI30 in 32 5 16 19 1 2 2 1 4 36 23 1 2 23 1 2 mm 821 495 57 914 597 584 13 COSMO I35 IFT FS MI35 in 37 5 16 23 1 2 2 1 4...

Страница 11: ...s Iron Age DECORATIVE BARRIER FRONTS IRON AGE A B C D E F G COSMO I30 IFT IA MI30 in 28 9 16 17 1 16 2 3 8 36 23 1 2 23 1 2 mm 725 433 60 914 597 584 13 COSMO I35 IFT IA MI35 in 33 9 16 20 1 2 2 3 8 4...

Страница 12: ...Arch DECORATIVE BARRIER FRONTS HALSTON ARCH A B C D E F G COSMO I30 IFT HARC MI30 in 31 3 8 15 9 16 3 7 8 36 1 4 23 1 2 23 1 2 mm 797 395 98 921 597 584 13 COSMO I35 IFT HARC MI35 in 36 3 8 19 1 16 3...

Страница 13: ...rap a 1 4 inch airspace MUST be provided between the insert and the floor of the outer wrap Use the leveling legs to raise the insert a minimum of 1 4 inch The original fireplace may never be returned...

Страница 14: ...Width Front 31 5 8 803 36 5 8 930 C Opening Height Front 21 533 24 1 4 616 D Opening Height Rear 19 3 16 487 21 11 16 551 E Unit Opening Depth 15 381 15 381 F Venting Depth Front 7 5 8 194 7 5 8 194...

Страница 15: ...through decorative barrier fronts Facing and or finishing materials must never overhang into the glass opening Observe all clearances when applying combustible materials Maximum depth of wall extensi...

Страница 16: ...es emerge adjacent to the fireplace it can be perma nently repaired by filling it with a paintable latex caulk followed by repainting Some movement of the screws used to secure the non combustible boa...

Страница 17: ...igure 3 15 Minimum Vertical and Maximum Horizontal Dimensions Non Combustible Mantels or Wall Projections Non Combustible 1 4 in gap SURROUND OPENING 6 in 12 in 12 in B SEE TABLE 1 or 2 Note Measureme...

Страница 18: ...tom of the surround See Figure 3 18 Combustible flooring may be located in front of the appliance See Figure 3 19 for vinyl flooring recommendations 1 2 inch gap under the bottom of the front must be...

Страница 19: ...ded to provide a minimum of 24 inches of clearance in front of the appliance to the vinyl floor ing OR the bottom of the appliance should be raised a minimum of 24 inches off of the floor to allow the...

Страница 20: ...e Section 7 It is recommended that extra length of gas line be installed within the existing wood burner or masonry fireplace to allow removal of the insert for future servicing needs D Fireplace Conv...

Страница 21: ...aximum Vertical Run Length 50 ft CAUTION ALL vent specifications MUST be followed This product is tested and listed to these specifications Appliance performance will suffer if specifications are not...

Страница 22: ...ICTORS IN THE OPEN POSITION AND BENT AT 90 RESTRICTOR DOORS Figure 5 3 Firebox Baffle To open restrictors push the restrictor doors upward The restrictor doors should be bent at a 90 See Figure 5 3 Fi...

Страница 23: ...INLET AIR VENT PIPE WARNING DO NOT BLOCK THIS PIPE END INLET AIR VENT PIPE EXHAUST AIR VENT PIPE OPTIONAL LINK ZC ADPB FOR USE WITH CLASS A WOODBURNING PIPE LINK DV4 30B LINKSQ DV4 30 Installation Ma...

Страница 24: ...ance is listed for use with LINK DV systems and components only It is permissible to extend venting above existing chimney within specified maximum ver tical limits using SLP series 6 5 8 inch gas dir...

Страница 25: ...st flexible vent pipe to the exhaust starting collar on top of the appliance with three screws See Figure 5 1 For best results in cold climate be sure 3 in flex is flush and tight to the collar slide...

Страница 26: ...ar on appliance and either the termination cap inlet air collar OR terminate within chimney DO NOT allow vent to sag below connection point to appliance Install insert without surround attached into e...

Страница 27: ...VERTICAL WALL GAS DIRECT VENT TERMINATION CAP 12 X ROOF PITCH IS X 12 LOWEST DISCHARGE OPENING 2 FT MIN 20 INCHES MIN H MIN MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING H minimum may vary depe...

Страница 28: ...ances the spark ignition of the fireplace may cause intermittent non damaging interference during the lighting sequence with a TV plugged into the same circuit It is recommended that the fireplace and...

Страница 29: ...ULE RESET SWITCH LOCATED ON SURROUND Reset switch must be installed and in the ON position for appliance to operate 2187 198 BATTERY PACK 2326 142 2532 301 B Wiring Requirements IntelliFire Touch Igni...

Страница 30: ...assembly and valve plate assembly See Figure 6 5 Service install fan Figure 6 2 shows a wiring diagram Reinstall valve plate assembly burner assembly base pan assembly logs and appliance glass and fro...

Страница 31: ...emoved for additional component accessibility Use multi purpose tool to assist with gas shutoff See Figure 7 1 The gas ball valve is in the OFF position from manufacturer WARNING Glass seal plate must...

Страница 32: ...ance requires proper input pressures Gas line sizing requirements will be determined in ANSI Z223 1 National Fuel Gas Code in the USA and CAN CGA B149 in Canada Pressure requirements are C Gas Connect...

Страница 33: ...utility to determine proper orifice size E Air Shutter Setting Air shutter settings should be adjusted by a qualified ser vice technician at the time of installation The air shutter is set at the fac...

Страница 34: ...Non Combustible 1 4 in gap SURROUND OPENING 6 in 12 in 12 in B SEE TABLE 1 or 2 Note Measurement is taken from top of the surround opening Mantel Legs or Wall Projections INTERIOR WALL TOP VIEW MANTE...

Страница 35: ...the surround See Figure 8 5 Combustible flooring may be located in front of the appliance Exception no vinyl adhesive flooring See Figure 8 6 1 2 inch gap under the bottom of the front must be maintai...

Страница 36: ...e 8 6 Hearth Combustible Material Exception NO VINYL ADHESIVE FLOORING SIDE VIEW MINIMUM 1 4 IN REQUIRED COMBUSTIBLE FLOOR UNDERNEATH APPLIANCE Appliance Size Depth X Width Y 30 in 16 in 30 3 4 in 35...

Страница 37: ...pring loaded glass latches An example of the glass latch is shown in Figure 9 2 To release glass assembly use the supplied multi purpose tool to pull the two bottom spring loaded latches forward and a...

Страница 38: ...for shipping C Clean the Appliance Clean vacuum any sawdust that may have accumulated inside the firebox or underneath in the control cavity D Accessories Install approved accessories per instructions...

Страница 39: ...Figure 2 Magic Glass Channels MAGIC GLASS CHANNELS Instructions 1 Position four 4 magic glass channels and screw into place See Figure 3 Figure 3 Position four 4 Magic Glass Channels Figure 4 Magic Gl...

Страница 40: ...anels Installed 2 Position rear glass refractory against the back of the firebox as shown in Figure 5 Secure by bending top tabs down Be sure to hold glass panel in position until tabs are holding gla...

Страница 41: ...ice needs 4 Reinstall seal plate glass assembly and decorative front Note A tall deep orange flame should be avoided this type of flame may cause increased soot residue If this type of flame is notice...

Страница 42: ...by Hearth Home Technologies Unapproved doors or fronts may cause fireplace to overheat This fireplace has been supplied with an integral barrier to prevent direct contact with the fixed glass panel D...

Страница 43: ...fireplace after 9 hours of continuous operation without receiving a command from the remote control If this occurs restart the appliance NOTICE Open windows for air circulation during fire place brea...

Страница 44: ...to 30 feet and 4 feet respectively Includes two liners termination cap and flashing Figure 10 1 Direct Vent Flex Liner Kits Figure 10 2 Direct Vent Flex Liner Accessory Kits Direct Vent Flex Liner Acc...

Страница 45: ...mote controls out of reach of children See your dealer if you have questions B Accessories Install approved accessories per instructions included with accessories Contact your dealer for a list of ap...

Отзывы: