If necessary a hole must be opened up into the flue way above the fireplace in order to fit the appliance to 
the flue correctly. Please consult HETAS recommended fitting methods if in doubt. It is 

essential

 that all 

connections between the stove and chimney-flue are sealed and made airtight with sealing rope, clamping 
rings and/or fire cement or heat resisting cement where required. 
 
Both the chimney and flue pipe must be accessible for cleaning and if ANY parts of the chimney cannot be 
reached through the stove (with baffle removed), a soot door must be fitted in a suitable position to enable 
this to be done. 
 

4.5 Fixing 

Fix the stove to the back hearth using suitable non-combustible fixings through the base of the outer firebox. 
If necessary screw the outer firebox to the back-panel by fixing the top or side flanges using suitable non-
combustible fixings. 
 

4.6 Material Clearances 

 

Safety Distances from Combustible Surfaces: 
Model  

 

 

 

Shelf   

Side 

(outer edge of trim)

 

FW5C  

 

 

 

250mm 

350mm 

 

 

 
In addition it is strongly recommended that any furniture or other combustible materials are kept at least 
900mm clear from the front of the stove. 
 

Distances from NON-combustible materials: 

The stove can be recessed in a suitable sized non-combustible fireplace but a permanent free air gap of at 
least 50mm must be left around the sides and top of the stove to obtain reasonable heat output and for access 
to the stove for removal and maintenance. A clearance of 150mm will give a better heat output 
 
To conform with building regulations the fireplace recess walls should be at least 200mm thick or each rear 
leaf at least 100mm thick in the case of a cavity wall at the rear. If these dimensions are not met further 
protection for any combustible materials must be provided. The walls of the fireplace recess and the hearth 
must be made of non-combustible material.  
 

4.7 Hearths: 

The FW5C stove require a 125mm thick non-combustible constructional hearth beneath them to protect the 
building, this can include any solid non-combustible floor. A non-combustible superimposed hearth forming 
an apron of at least 225mm at the front of the stove and 150mm on either side must also be provided. The 
superimposed hearth must not be less than 12mm thick and must have a clearly defined edge (change of 
level) to discourage placing of any combustible materials on or partially over it.  
 
The appliance shall be installed on a floor with adequate load-bearing capacity. If the existing construction 
does not meet this requirement, suitable measures (e.g. load distributing plate) should be provided to achieve 
it. 

 
4.8 Commissioning and Handover 

Upon completion of the installation, allow a suitable period of time for any fire cement and mortar to dry 
out. A small fire may then be lit and checked to ensure the smoke and fumes are taken from the stove up the 
chimney and emitted safely to atmosphere.  
 
Advise the customer not to run the stove at full output for at 3 – 4 days. Explain that the stoves can provide 
much more or less than their rated heat outputs depending upon how they are burnt and fuels and fuel loads 
used. 
 

Содержание FW5C

Страница 1: ...d operation of controls Important This product must be installed by a suitably qualified installer Heat Design 30 60 Hawthorn Road Western Industrial Estate Naas Road Dublin 12 www heatdesign ie PLEAS...

Страница 2: ...Chimney 4 4 2 Ventilation 4 4 3 Flue Draught 5 4 4 Connection to Chimney 5 4 5 Material Clearances 5 4 6 Fixing 5 4 7 Hearths 6 4 8 Commissioning Handover 6 5 Technical Data 6 6 Operating Instructions...

Страница 3: ...front door Then remove the two side firebricks and the two rear firebricks Handle store very carefully to one side where they will not get broken 2 2 Now lift up the grate and carefully remove this f...

Страница 4: ...lly regularly in use and especially after a period on disuse e g after summer Lift down the baffle at least weekly to check for build up of soot or debris on the top from the flue pipe Remove the baff...

Страница 5: ...tilation is recommended however it is not required in England and Wales unless the appliance rated output is greater than 5kW Over 5kW 5 5 cm2 of ventilation 550mm2 is required for every kW output abo...

Страница 6: ...clearance of 150mm will give a better heat output To conform with building regulations the fireplace recess walls should be at least 200mm thick or each rear leaf at least 100mm thick in the case of...

Страница 7: ...be kept clear from obstruction Warning This appliance will be very hot when in operation and due care should be taken when operating the controls A leather glove is provided to assist safe operation D...

Страница 8: ...use a wet cloth with some of the wood ash if burning wood but be very careful to use very clean ash so as not to scratch the glass Outer body The outer body simply needs to be dusted from time to time...

Страница 9: ...ke emission DO NOT leave the stove unattended if the door is left ajar Allow the fuel to reach a steady glow and build the fire up gradually by adding a few small sticks or well split logs at a time O...

Страница 10: ...ed the fire is in an over fire situation and the controls should be adjusted accordingly Never leave the stove unattended for long periods without first adjusting the controls to a reduced and safe se...

Страница 11: ...10 HD02 01 10 11 Fig 3 FW5C Cassette Stove Dimensions...

Страница 12: ...attends any stove problem that is not related to product failure 6 Where can I get spare parts Your local Firewarm Stove retailer will be pleased to supply spare parts and to provide any other informa...

Страница 13: ...12 HD02 01 10 11 Heat Design 30 60 Hawthorn Road Western Industrial Estate Naas Road Dublin 12 T 01 408 9192 F 01 408 9193...

Страница 14: ...13 HD02 01 10 11...

Отзывы: