Heat Controller RADS-151G Скачать руководство пользователя страница 9

Heat Controller, Inc. 

Room Air Conditioner with R-410A

 

Owner’s Manual

8

Temp

Temp

Timer

Timer

On

Off

Sleep

Check

Filter

Timer

Auto

Cool

Dry

Fan

Low

Auto

Med

High

Clean

Air

TIMER: AUTO START/

STOP FEATURE:

Press Timer
button

DO THIS:

AIR CONDITIONER FEATURES(CONTINUED)

First press the Timer button, the indicator light
besides word On illuminates. It indicates the Auto
Start program is initiated.
Press or hold the Left arrow or Right arrow to change
the Auto time by 0.5 hour increments, up to 10 hours,

then at 1 hour increments up to 24 hours. The control
will count down the time remaining until start.
The selected time will register in 5 second and the
system will automatically revert back to display the

previous temperature setting.
Turning the unit ON or OFF at any time will cancel the

Auto Start/Stop function.

NOTE:

Temp

Temp

Timer

Timer

On

Off

Sleep

Check

Filter

Timer

Auto

Cool

Dry

Fan

Low

Auto

Med

High

Clean

Air

CHECK FILTER FEATURE:

Press Check
Filter button

DO THIS:

Temp

Temp

Timer

Timer

On

Off

Sleep

Check

Filter

Timer

Auto

Cool

Dry

Fan

Med

High

Clean

Air

CLEAN AIR FEATURE:

(on some models)

Press Clean
Air button

DO THIS:

This feature is a reminder to clean the Air Filter for
more efficient operation. The LED(light) will illumi-

nate after 250 hours of operation. To reset after
cleaning the filter, press the Check Filter button and
the light will go off.

NOTE:

Press the Clean Air button, the ion generator is ener-
gized and will help to remove pollen and impurities
from the air, and trap them in the filter.

NOTE:

8

AIR CONDITIONER FEATURES (CONTINUED)

Press the Timer button, the indicator 

light

the time by 0.5 hour increments, up to 10 hours

AIR CONDITIONER FEATURES(CONTINUED)

TO SELECT THE

OPERATING MODE:

Press the Mode
button.

DO THIS:

To choose operating mode, press the Mode button.
Each time you press the button, a mode is selected
in a sequence that goes from Auto, Cool, Dry , Heat
(Cooling only models without) and Fan. The indicator

light beside will be illuminated and remained on

once the mode is selected.

NOTE:

To operate on Auto feature:

In this mode, the fan speed cannot be adjusted, it
starts automatically at a speed according to the
room temperature. If the room does not get too
warm, it will stay at Low speed.

To operate on Fan Only:

Use this function only when cooling is not desired,
such as for room air circulation or to exhaust stale
air(on some models). (Remember to open the vent
during this function, but keep it closed during

cooling for maximum cooling efficiency.) You can
choose any fan speed you prefer.
During this function, the display will show the actual
room temperature, not the set temperature as in the

cooling mode.

TO USE THE ENERGY

SAVER FEATURE:

Press the button

DO THIS:

In this mode, the fan will continue to run for 3 minutes
after the compressor shuts off. The fan then cycles
on for 2 minutes at 10 minute intervals until the room
temperature is above the set temperature, at which
time the compressor turns back on and cooling stars.

NOTE:

SLEEP FEATURE:

Press Sleep
button

DO THIS:

In this mode the selected temperature will increase by
2 degrees F 30 minutes after the mode is selected.
The temperature will then increase by another 2
degrees F after an additional 30 minutes. This new
temperature will be maintained for 7 hours before it

returns to the originally selected temperature. This
ends the Sleep mode and the unit will continue to
operate as originally programmed. The Sleep mode
program can be cancelled at any time during operation

by again pressing the Sleep button.

NOTE:

7

Energy

Saver

on

off

Timer

Auto

Fan

Cool

Dry

Mode

TEMP/TIMER

TEMP/TIMER

Heat

Energy

Saver

on

off

Timer

Auto

Fan

Cool

Dry

Mode

TEMP/TIMER

TEMP/TIMER

Sleep

Check

Filter

Follow

Me

Auto

On/off

Fan

High

Med

Low

on

off

Timer

TEMP/TIMER

TEMP/TIMER

Clean

Air

Clean

Air

To operate on Dry mode:

In this mode, the air conditioner will generally
operate in the form of a dehumidifier. Since the
conditioned space is a closed or sealed area, some
degree of cooling will continue.

TIMER: AUTO START/

STOP FEATURE:

Press Timer
button

DO THIS:

AIR CONDITIONER FEATURES(CONTINUED)

First press the Timer button, the indicator light
besides word On illuminates. It indicates the Auto
Start program is initiated.
Press or hold the Up(

) or Down(

) to change

the Auto time by 0.5 hour increments, up to 10 hours,
then at 1 hour increments up to 24 hours. The control
will count down the time remaining until start.
The selected time will register in 5 second and the
system will automatically revert back to display the

previous temperature setting.
Turning the unit ON or OFF at any time will cancel

the Auto Start/Stop function.

NOTE:

CHECK FILTER FEATURE:

Press Check
Filter button

DO THIS:

This feature is a reminder to clean the Air Filter for
more efficient operation. The LED(light) will illumi-

nate after 250 hours of operation. To reset after
cleaning the filter, press the Check Filter button and
the light will go off.

NOTE:

8

Energy

Saver

on

off

Timer

Auto

Fan

Cool

Dry

Mode

TEMP/TIMER

TEMP/TIMER

Sleep

Check

Filter

Follow

Me

Auto

On/off

Fan

High

Med

Low

on

off

Timer

TEMP/TIMER

TEMP/TIMER

FOLLOW ME FEATURE:

(on some models)

Light flashing

NOTE:

To activate the Follow Me feature, point the remote
control towards the unit and press the Follow Me
button. T

If the unit

does not receive the Follow Me signal during any 7
minute interval, the unit will beep to indicate the
Follow Me mode has ended.
The actual temperature can be displayed at the unit
by pressing the Fan Only mode. When in the Cool

mode, the unit display indicates the set temperature.

he remote display is actual temperature

at its location. The remote control will send this
signal to the air conditioner every 3 minutes interval
until press the Follow Me button again.

This feature can be activated from the remote
control ONLY. The remote control serves as a
remote thermostat allowing for the precise
temperature control at its location.

Sleep

Check

Filter

Follow

Me

Auto

On/off

Fan

High

Med

Low

on

off

Timer

TEMP/TIMER

TEMP/TIMER

Clean

Air

Содержание RADS-151G

Страница 1: ...RADS 151G RADS 183G RADS 253G Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER MULTI STEP SPEED ELECTRONIC CO...

Страница 2: ...children should be supervised to ensure that they do not play with the air conditioner If the power cord is to be replaced replacement work shall be performed by authorised personnel only Installation...

Страница 3: ...heating appliances Do not damage or use an unspecified power cord Do not direct airflow at room occupants only Always install circuit breaker and a dedicated power circuit Do not open the unit during...

Страница 4: ...may cause failure It contains contaminants and could make you sick Always insert the filters securely Clean filter once every two weeks Do not drink water drained from air conditioner It may cause an...

Страница 5: ...damaged it cannot be repaired It MUST be replaced by one NOTES obtained from the product manufacturer 4 Please refer to the section Operation of Current Device for details IMPORTANT SAFETY INSTRUCTION...

Страница 6: ...tion may cause pinging or switching sounds Before you begin thoroughly familiarize yourself with the control panel and remote as shown below and all its functions then follow the symbol for the functi...

Страница 7: ...r High Each time the button is pressed the fan speed mode is shifted NOTE 6 AIR CONDITIONER FEATURES CONTINUED TO TURN UNIT ON NOTE The following instructions represent the Unit Controls the same inst...

Страница 8: ...idifier to remove moisture from the air Since the conditioned space is a closed or sealed area some degree of cooling will continue starts each mode will be illuminated AIR CONDITIONER FEATURES CONTIN...

Страница 9: ...ees F after an additional 30 minutes This new temperature will be maintained for 7 hours before it returns to the originally selected temperature This ends the Sleep mode and the unit will continue to...

Страница 10: ...again If the unit Filter button nate after 250 hours of operation To reset after cleaning the filter press the Check Filter button and the light will go off 8 Me Auto On off Fan High Med Low on off Ti...

Страница 11: ...S CONTINUED that again 2 F 1 C between 60 F 16 C and 90 F 32 C ADDITIONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating procedure here are more features in your control that you shou...

Страница 12: ...removing storm window while room air conditioner is being installed Check your storm windows 4 check area outside of window for things such as shrubs trees or awnings Inside be sure furniture drapes o...

Страница 13: ...il Level Socket wrenches Phillips Screwdriver 11 7 16 inch Locking screw and Flat washer for window panels 3 4 inch Long Hex head Screw Safety Lock 1 2 inch Long screw and Locknut 3 4 inch Long Flat H...

Страница 14: ...Angle and Side Bracket 1 Attach foam gasket to top angle above holes as shown in Fig 6 2 Install top angle and side retainers to cabinet as shown in Fig 6 3 Assemble Window Filler Panels 1 Place cabi...

Страница 15: ...et in place Stool Stool Angle 13 5 Install Support Bracket 1 Hold each support bracket flush against outside of sill and tight to bottom of cabinet as shown below Mark brackets at top level of sill an...

Страница 16: ...2 Long Screws and Locknuts Locking Screw 7 Install Window Lock and Sash Seal 1 Trim sash seal to fit window width Insert into space between upper and lower sashes 2 Attach right angle safety lock as...

Страница 17: ...the installation instructions Cover it with plastic or return it to the original carton Note Cabinet Cleaning Winter Storage 14 WARNING 104 F 40 C CARE AND CLEANING Clean your air conditioner occasio...

Страница 18: ...Turn Control ON and set to desired setting O O O O Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front Outdoor temperature below 18 C 64 F To defrost the c...

Страница 19: ...days Remote Sensing Deactivating Prematurely some models Remote control not located within range Place remote control within 20 feet 180 radius of the front of the unit Remote control signal obstructe...

Страница 20: ...04 2009 11 2009...

Отзывы: