Heat Controller RADS-151G Скачать руководство пользователя страница 15

Heat Controller, Inc. 

Room Air Conditioner with R-410A

 

Owner’s Manual

14

3. Insert top and bottom legs of window

filler panel frame into channel in the
top angle and bottom rail. Do both
sides.

4. Insert washer head locking screws

(2) into holes in top leg of filler panel
frame (see step 6). Do not totally tigh-
ten. Allow leg to slide freely. Screws
will be tightened after section 6.

4

Install Top Angle and

Side Bracket

3. Shift cabinet left or right as needed to line up

center of cabinet on center line marked on stool.

4. Fasten cabinet to window stool with 2 screws

into holes(You may wish to pre-drill pilot holes).

5. Add bottom rail seal over screws to window stool.

1. Open window and mark center of window stool.
2. Place cabinet in window with bottom stool angle

firmly seated over window stool as shown. Bring
window down temporarily behind top angle to
hold cabinet in place.

Stool

Stool
Angle

13

5

Install Suppor t Bracket

1. Hold each support bracket flush against

outside of sill, and tight to bottom of cabinet
as shown below. Mark brackets at top level
of sill, and remove.

2. Assemble sill angle bracket to support

brackets at the marked position, as shown.
Hand tighten, but allow for any changes later.

Top
View

Air Conditioner
Cabinet

Plastic
Frame

I Section

Window

Filler

Panel

Locking

Screw

Hole

Bottom
Rail Seal

3 4 Long
Hex-head Screw

Mark

1 2 Long Screws
And Locknuts

Left

Right

Sill Angle
Bracket

Flat Head
Bolt

2 Each Required For
Each Support Bracket

Locknut

1. Open window and mark center of window sill.

2. Place cabinet in window with bottom sill angle firmly 

seated over window sill as shown. Bring window 

down temporarily behind top angle to hold cabinet 

in place.

Sill

Sill

3. Shift cabinet left or right as needed to line up center 

of cabinet on center line marked on sill.

4. Fasten cabinet to window sill with 2 screws into holes 

(pre-drill pilot holes if needed).

5. Add bottom rail seal over screws to window sill

Содержание RADS-151G

Страница 1: ...RADS 151G RADS 183G RADS 253G Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER MULTI STEP SPEED ELECTRONIC CO...

Страница 2: ...children should be supervised to ensure that they do not play with the air conditioner If the power cord is to be replaced replacement work shall be performed by authorised personnel only Installation...

Страница 3: ...heating appliances Do not damage or use an unspecified power cord Do not direct airflow at room occupants only Always install circuit breaker and a dedicated power circuit Do not open the unit during...

Страница 4: ...may cause failure It contains contaminants and could make you sick Always insert the filters securely Clean filter once every two weeks Do not drink water drained from air conditioner It may cause an...

Страница 5: ...damaged it cannot be repaired It MUST be replaced by one NOTES obtained from the product manufacturer 4 Please refer to the section Operation of Current Device for details IMPORTANT SAFETY INSTRUCTION...

Страница 6: ...tion may cause pinging or switching sounds Before you begin thoroughly familiarize yourself with the control panel and remote as shown below and all its functions then follow the symbol for the functi...

Страница 7: ...r High Each time the button is pressed the fan speed mode is shifted NOTE 6 AIR CONDITIONER FEATURES CONTINUED TO TURN UNIT ON NOTE The following instructions represent the Unit Controls the same inst...

Страница 8: ...idifier to remove moisture from the air Since the conditioned space is a closed or sealed area some degree of cooling will continue starts each mode will be illuminated AIR CONDITIONER FEATURES CONTIN...

Страница 9: ...ees F after an additional 30 minutes This new temperature will be maintained for 7 hours before it returns to the originally selected temperature This ends the Sleep mode and the unit will continue to...

Страница 10: ...again If the unit Filter button nate after 250 hours of operation To reset after cleaning the filter press the Check Filter button and the light will go off 8 Me Auto On off Fan High Med Low on off Ti...

Страница 11: ...S CONTINUED that again 2 F 1 C between 60 F 16 C and 90 F 32 C ADDITIONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating procedure here are more features in your control that you shou...

Страница 12: ...removing storm window while room air conditioner is being installed Check your storm windows 4 check area outside of window for things such as shrubs trees or awnings Inside be sure furniture drapes o...

Страница 13: ...il Level Socket wrenches Phillips Screwdriver 11 7 16 inch Locking screw and Flat washer for window panels 3 4 inch Long Hex head Screw Safety Lock 1 2 inch Long screw and Locknut 3 4 inch Long Flat H...

Страница 14: ...Angle and Side Bracket 1 Attach foam gasket to top angle above holes as shown in Fig 6 2 Install top angle and side retainers to cabinet as shown in Fig 6 3 Assemble Window Filler Panels 1 Place cabi...

Страница 15: ...et in place Stool Stool Angle 13 5 Install Support Bracket 1 Hold each support bracket flush against outside of sill and tight to bottom of cabinet as shown below Mark brackets at top level of sill an...

Страница 16: ...2 Long Screws and Locknuts Locking Screw 7 Install Window Lock and Sash Seal 1 Trim sash seal to fit window width Insert into space between upper and lower sashes 2 Attach right angle safety lock as...

Страница 17: ...the installation instructions Cover it with plastic or return it to the original carton Note Cabinet Cleaning Winter Storage 14 WARNING 104 F 40 C CARE AND CLEANING Clean your air conditioner occasio...

Страница 18: ...Turn Control ON and set to desired setting O O O O Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front Outdoor temperature below 18 C 64 F To defrost the c...

Страница 19: ...days Remote Sensing Deactivating Prematurely some models Remote control not located within range Place remote control within 20 feet 180 radius of the front of the unit Remote control signal obstructe...

Страница 20: ...04 2009 11 2009...