MGD Series Gas Furnace                                                                                        Installation Instructions 

Heat Controller, Inc. Jackson, MI 49203                                              MGD Installation Instructions     3 

  
  

SAFETY CONSIDERATIONS                                INSTALLATION STANDARDS

 

                            

 

CODE COMPLIANCE 

 

The installer shall become familiar with and follow all local 
codes and regulations which govern the installation of this 
furnace. Where applicable, local codes may take precedence. 

 

• 

Federal Manufactured Home Construction and Safety  
Standards – HUD Title 24, Part 3280. 

• 

National Fuel Gas Code – ANSI-Z223.1/NFPA-54 

• 

Unit electrical wiring and grounding shall comply with 
National Electrical Code – ANSI/NFPA-70 

• 

“Manufactured Housing” – NFPA-501 and Fire Safety Criteria 
for Mobile Home Installations – NFPA 501A 

• 

“Recreational Vehicles” – ANSI – 119/NFPA – 501C 

 

HIGH ALTITUDE INSTALLATION 

 

For elevations above 2,000 feet derate furnace input 4% for each 
1,000 feet of elevation above sea level. Furnace deration is 
accomplished by reducing the burner orifice size. See 
DERATING CHART for orifice size and CONVERSION 
INSTRUCTIONS, Page 16. 

 

INSTALLATION CLEARANCES 

 

These furnaces are design certified for the following minimum 
clearances from combustible materials in alcove or close 
instllations. 

 
 
 
 
 
 

 
NOTE:

  The words “Shall” or “Must” indicate a 

requirement, which is essential to satisfactory and safe 
furnace performance. 

 

The words “Should” or “May” indicate a recommendation 
which may be helpful or enhance performance. 

Locate furnace to ensure adequate room for service access to all 
vent connections, controls and the heat exchanger. A front 
clearance of 18” minimum (24” recommended) shall be 
provided by a closet door or spacing away from a facing wall or 
partition. 
 
For installation on combustible flooring (except carpeting) using 
manufacturers supplied floor base P/N 87FB0005 and duct    
Connector Series P/N 86AA001, included in 90-DCU0-01/03  
kits. 

 

                    

 

 

• 

ELECTRIC POWER 

- turn off all electrical 

power to furnace before performing any 
maintenance or service on unit. Failure to take 
this precaution may result in personal injury due 
to electrical shock. 
• 

SERVICE 

- a qualified service technician 

should service this unit. Fuel burning appliances 
can generate toxic flue products. Modification of 
the appliance can cause carbon monoxide in 
deadly amounts. To prevent a safety hazard, 
maintain this 
appliance in a safe operating manner and do not 
modify. 
• 

DO NOT 

modify vent or operate the unit with a 

blocked vent or inlet air pipe. 
• 

DO NOT 

re-drill a burner orifice. If the orifice 

size must be changed, use only a new orifice. 
• 

DO NOT 

use matches, lighters, candles, or 

other sources of open flame to check for gas 
leaks. 
• 

PROPER 

maintenance for this unit requires 

certain mechanical skills and tools. If you are at 
all uncertain, contact your Heating Service Co. 
for maintenance and service. 
• 

CONSULT 

with a service technician for any 

problems or questions you may have pertaining 
to this appliance. 
• 

ALWAYS 

inspect the appliance before starting 

a new heating season, paying special attention to
vent pipes and fuel lines.

 

Top ……………………………….6 in. 
Sides ……………………………...0 in. 
Back ………………………………0 in. 
Alcove-front of furnace ………….18 in. 
Closet-front of furnace ……………6 in. 
Duct ……………………………….0 in. 
Vent/Roof Jack ……………………0 in. 
 
* If the return air opening is below the top of the   
furnace, clearance to the side or rear shall be 6”. 
 
** See Return Air for clearances less than 6”.

Содержание MGD60-E3A

Страница 1: ...ructions are intended to assist qualified individuals experienced in the installation of heating equipment Some state and local codes require installation personnel to be licensed Read all instruction...

Страница 2: ...Amp Thermostat Circuit 24VAC 60Hz 40VA Filters 1 16 x40 x1 Washable PRODUCT CODE PART NO DESCRIPTION NOTES 90 RJF1729 AL Body Roof Jack Gas FLAT Height 94 1 2 X 106 1 2 90 RJF2551 AL Body Roof Jack Ga...

Страница 3: ...18 minimum 24 recommended shall be provided by a closet door or spacing away from a facing wall or partition For installation on combustible flooring except carpeting using manufacturers supplied floo...

Страница 4: ...he opening 3 The cross sectional area of the return system when located in the floor or ceiling of the manufactured home leading into the closet is to be not less than that of the opening specified on...

Страница 5: ...MGD Series Gas Furnace Installation Instructions Heat Controller Inc Jackson MI 49203 MGD Installation Instructions 5...

Страница 6: ...MGD Series Gas Furnace Installation Instructions Heat Controller Inc Jackson MI 49203 MGD Installation Instructions 6...

Страница 7: ...MGD Series Gas Furnace Installation Instructions Heat Controller Inc Jackson MI 49203 MGD Installation Instructions 7 SEALED COMBUSTION ROOF JACK REQUIRED...

Страница 8: ...he 7 collar 5 Check and make sure the combustion air pipe is fully seated Then drive a 10 sheet metal screw attaching pipe firmly to furnace collar 6 Install optional ceiling trim ring 90 TRM RNG 7 On...

Страница 9: ...a strain relief bushing on the left side of the furnace 3 Connect the HOT wire to the black pigtail lead connect the NEUTRAL wire to the WHITE pigtail lead Secure the connections with suitable wire n...

Страница 10: ...D TUBING MIN SIZES MODEL TYPE LENGTH PIPE TUBING MGD OF SIZE SIZE GAS FT IN IN OD to 20 3 8 5 8 Natural to 60 1 2 60 to 70 3 4 to 40 3 8 Propane to 70 5 8 to 80 1 2 to 20 5 8 to 50 1 2 Natural to 60 3...

Страница 11: ...MGD Series Gas Furnace Installation Instructions Heat Controller Inc Jackson MI 49203 MGD Installation Instructions 11 WIRING DIAGRAM MGD...

Страница 12: ...MGD Series Gas Furnace Installation Instructions Heat Controller Inc Jackson MI 49203 MGD Installation Instructions 12 REPLACEMENT PARTS...

Страница 13: ...1 Transformer 115V 24V 40VA 12 All R68CA0004 1 Limit Switch Open 140 F Close 110 F 13 All R86GF0054 1 Burner Assembly 14 All R68GF0005 1 Hot Surface Igniter 15 All R76AA0002 2 Filter 16 X 20 X 1 16 A...

Страница 14: ...3 MGD Installation Instructions 14 Reference NFPA No 54 ANSI Z 223 1 National Fuel Gas Code Table shows 4 Input Reduction per 1 000 feet elevation For Canadian High Altitude 2 000 4 500 feet reduce ga...

Отзывы: