background image

MGD Series Gas Furnace                                                                                        Installation Instructions 

Heat Controller, Inc. Jackson, MI 49203                                              MGD Installation Instructions     2 

              

SPECIFICATIONS 

80 AFUE- AUTOMATIC  HOT SURFACE 
IGNITION 

  

  

 

  

  

  

Model No. 

MGD60-E3A MGD75-E3A 

MGD90-E3A   MGD60-E5A  MGD75-E5A  MGD90-E5A

Input, BTUH 

60,000 

75,000 

90,000   60,000 

75,000 

90,000 

Output, BTUH 

48,000 

60,000 

72,000   48,000 

60,000 

72,000 

AFUE, % 

80.0 

81.0 

80.0   80.0 

81.0 

80.0 

With A-Coil Cabinet 

YES 

YES 

YES 

 

YES 

YES 

YES 

Ignition Type 

Auto-Elect 

Auto-Elect 

Auto-Elect   Auto-Elect 

Auto-Elect Auto-Elect 

Air Temperature Rise, Range-F 

40-70 45-75  50-80 

 

40-70  45-75  50-80 

Blower 

10 X 8, 1/3 HP, 3 SPD 

 

10 X 8, 3/4 HP, 4 SPD 

Designed Max Outlet Air Temp-F 

165 

°

 

Max. External SP (Duct),In. W.C. 

.30 Heating 

Factory Equipped Fuel 

Natural Gas (Factory Equipped) - LP Orfice Furnished 

High Altitude 

For elevations above 2,000 feet, reduce input 4% for each 1,000 ft. elevation above sea level 

Furnace Flue Pipe 

Must Use RJS Roof Jack for Sloped Roof or RJF Roof Jack for Flat Roof 

Gas Connection 

1/2" FPT 

Electric Service 

115 VAC, 60 HZ, 1 PH 

Fuse or Circuit Breaker 

15 Amp 

Thermostat Circuit 

24VAC, 60Hz, 40VA 

Filters   

1-16"x40"x1" Washable 

 
PRODUCT CODE 

 

 

 

PART NO. 

DESCRIPTION 

NOTES 

90-RJF1729-AL 

Body, Roof Jack, Gas-FLAT 

Height 94 1/2 X 106 1/2 

90-RJF2551-AL 

Body, Roof Jack, Gas-FLAT 

Height 102 1/2 X 128 1/2 

90-RJS1729-AL 

Body, Roof Jack, Gas-SLOPE 3/12 

Height 94 1/2 X 106 1/2 

90-RJS2551-AL 

Body, Roof Jack, Gas-SLOPE 3/12 

Height 102 1/2 X 128 1/2 

90-RJS3868-AL 

Body, Roof Jack, Gas-SLOPE 3/12 

Height 115 1/2 X 145 1/2 

90-RJS6399-AL 

Body, Roof Jack, Gas-SLOPE 3/12 

Height 140 1/2 X 176 1/2 

90-RJCRWN-AL 

Crown, Roof Jack, Gas 

Use w/ Gas Roof Jack Body 

90-TRN-RNG 

Ceiling Trim Ring, Roof Jack 

Trim out to inside RJ - Pipe 

90-OUTXT16-AL 

Roof Jack Outdoor Extension - Gas 16" 

Extend pipes / crown - 16 in. 

90-INXST10-AL 

Roof Jack Indoor Extension - Gas 10" 

Extend pipes / crown - 10 in. 

90-RJS56 

5-6/ 12 Slope, Roof Saddle Adapter 

Add to RJS 3/12 Roof Jack 

90-DCU0-01 

86AA0013 Duct Conn + 87FB0005 Flr Base Floor to Duck 1 in. - 4 in. 

90-DCU0-02 

86AA0014 Duct Conn + 87FB0005 Flr Base Floor to Duck 6 in. - 8 in. STD 

90-DCU0-03 

86AA0015 Duct Conn + 87FB0005 Flr Base Floor to Duck 8 in. - 12 in. 

90-CABEXT4 

White, Top, Cabinet Extender Plate 

Fill alcove 76" top opening 

87-1008-3/12A1 

A/C Blower, 3 Speed - 1/3 HP 

2 - 4 Ton A/C 

87-1008-4/16A1 

A/C Blower, 3 Speed - 3/4 HP 

2 - 5 Ton A/C 

Содержание MGD60-E3A

Страница 1: ...ructions are intended to assist qualified individuals experienced in the installation of heating equipment Some state and local codes require installation personnel to be licensed Read all instruction...

Страница 2: ...Amp Thermostat Circuit 24VAC 60Hz 40VA Filters 1 16 x40 x1 Washable PRODUCT CODE PART NO DESCRIPTION NOTES 90 RJF1729 AL Body Roof Jack Gas FLAT Height 94 1 2 X 106 1 2 90 RJF2551 AL Body Roof Jack Ga...

Страница 3: ...18 minimum 24 recommended shall be provided by a closet door or spacing away from a facing wall or partition For installation on combustible flooring except carpeting using manufacturers supplied floo...

Страница 4: ...he opening 3 The cross sectional area of the return system when located in the floor or ceiling of the manufactured home leading into the closet is to be not less than that of the opening specified on...

Страница 5: ...MGD Series Gas Furnace Installation Instructions Heat Controller Inc Jackson MI 49203 MGD Installation Instructions 5...

Страница 6: ...MGD Series Gas Furnace Installation Instructions Heat Controller Inc Jackson MI 49203 MGD Installation Instructions 6...

Страница 7: ...MGD Series Gas Furnace Installation Instructions Heat Controller Inc Jackson MI 49203 MGD Installation Instructions 7 SEALED COMBUSTION ROOF JACK REQUIRED...

Страница 8: ...he 7 collar 5 Check and make sure the combustion air pipe is fully seated Then drive a 10 sheet metal screw attaching pipe firmly to furnace collar 6 Install optional ceiling trim ring 90 TRM RNG 7 On...

Страница 9: ...a strain relief bushing on the left side of the furnace 3 Connect the HOT wire to the black pigtail lead connect the NEUTRAL wire to the WHITE pigtail lead Secure the connections with suitable wire n...

Страница 10: ...D TUBING MIN SIZES MODEL TYPE LENGTH PIPE TUBING MGD OF SIZE SIZE GAS FT IN IN OD to 20 3 8 5 8 Natural to 60 1 2 60 to 70 3 4 to 40 3 8 Propane to 70 5 8 to 80 1 2 to 20 5 8 to 50 1 2 Natural to 60 3...

Страница 11: ...MGD Series Gas Furnace Installation Instructions Heat Controller Inc Jackson MI 49203 MGD Installation Instructions 11 WIRING DIAGRAM MGD...

Страница 12: ...MGD Series Gas Furnace Installation Instructions Heat Controller Inc Jackson MI 49203 MGD Installation Instructions 12 REPLACEMENT PARTS...

Страница 13: ...1 Transformer 115V 24V 40VA 12 All R68CA0004 1 Limit Switch Open 140 F Close 110 F 13 All R86GF0054 1 Burner Assembly 14 All R68GF0005 1 Hot Surface Igniter 15 All R76AA0002 2 Filter 16 X 20 X 1 16 A...

Страница 14: ...3 MGD Installation Instructions 14 Reference NFPA No 54 ANSI Z 223 1 National Fuel Gas Code Table shows 4 Input Reduction per 1 000 feet elevation For Canadian High Altitude 2 000 4 500 feet reduce ga...