‘D’ Series
Ceiling Cassette Systems
208-230V/60/1
Features
n
Multiple Modes for Comfort
—Cooling, fan
only, dehumidifi cation only, auto sleep modes
n
Auto Operation
—Fan speed and temperature
are automatically adjusted according to the actual
temperature of the room
n
Timer Modes
—Can be programmed for daily,
weekly and holiday operation for energy savings
when the room is not being used
n
Swirl Mode
—Controls the louvers to reduce
temperature stratifi cation; louver swing delivers
uniform comfort
n
Plasma Air Purifying Filter
—High tech fi lter
improves indoor air quality; unit also includes a
washable air fi lter
n
Auto Restart
—Reverts to last programmed
setting after a power failure
n
Self-Diagnostics
—Indicates when
maintenance is required
Our indoor cooling only units fi t fl ush in the
ceiling with an attractive panel incorporating
airfl ow louvers. A small light display on the
indoor unit shows operation and if the timer is in
use, plus signals when the fi lter needs changing.
A full featured wireless remote and a wired wall
remote to control operation and program the unit
are both included.
To optimize comfort and minimize energy
consumption, a multi-stage compressor system in
the 36,000 BTUH unit uses two compressors that
operate individually or in tandem to closely match
the load for greatest effi ciency.
24,000 BTUH
36,000 BTUH
24 000 BTUH
3
36
000 BTU
H
208
16
Offi ces are ideal locations for ceiling cassettes...the overhead location
allows conditioned air to reach cubicles and work areas within a single
space. Units can be programmed on a weekly basis for comfort during
working hours and energy savings in the evenings or on weekends.
Warranty—5 years on compressor, 1 year on parts
(Some limitations apply; see printed warranty for details.)
* Always follow local, state and national electrical codes. Main power
connection is 208/230V.
Cooling Only
FEATURES
DMC24CA-1
DMC36CA-1
Power Supply
208/230-1-60
208/230-1-60
Cooling Cap. (BTUH)
23,500/24,000
33,500/34,000
SEER
13.0
13.0
Dehumidify (Pts/Hr.)
6.3
7.8
Indoor Unit
Air Flow (CFM) H/M/L
650/600/550
850/800/750
Fan Speeds (Cool/Fan)
3 / 3
3 / 3
Air Direction–Four Way
Standard
Standard
24 Hr. Timer/Sleep Mode
Standard
Standard
Defrost Control
Standard
Standard
Electrical Data Outdoor Unit*
Main Pwr. Connection
Outdoor Unit
Outdoor Unit
Min. Circuit Ampacity
16.8
24.3
Max. Fuse/HACR Cir Brkr.
25
40
Indoor/Outdoor Connection
Line Voltage
Per NEC*
Line Voltage
Per NEC*
Indoor Unit Chassis Dimensions
Width (inches)*
33
33
Height (inches)
8
8
8
Depth (inches)*
33
33
Shipping Wt (lbs)
70
70
Outdoor Unit Dimensions
Width (inches)
34
35
Height (inches)
31
½
Depth (inches)
12
14
Shipping Wt. (lbs)
175
210
C US