Heat Controller Comfort-Aire PS-101A Скачать руководство пользователя страница 5

5

Heat Controller, Inc. 

PS-81, 101, 121A

 

Installation, Operation & Maintenance

IDENTIFICATION  OF  PARTS

Front

Control Panel

Horizontal Louver Blade

(swings automatically)

Casters

Carrying Handles 

(both sides)

1

2

3

4

1

2

3

4

Fig.1

Fig.2

Rear

9

6

7

8

10

11

6

7

8

9

10

11

Upper Air Filter

    (Behind the grille)

Air Outlet 

Power cord outlet 

Air intake

Drain Outlet 

Air intake

Lower Air Filter

(Behind the grille)

Bottom tray drain outlet

12

12

13

13

AIR  CONDITIONER  FEATURES

Before you begin, thoroughly familiarize yourself with the functions control panel and remote  

controller. 

The unit can be controlled by the unit control panel alone or with the remote controller . 

ELECTRONIC CONTROL OPERATING INSTRUCTIONS

Fig.3

 NOTE: This manual does not include Remote Controller Operations, see the <<Remote 

 Controller Instruction>> packed with the unit for details. 

OPERATION PANEL OF THE AIR CONDITIONER

6

2

3

4

5

7

1

Selects the appropriate operating mode. 

Each time you press the button, a mode

is selected in a sequence that goes from  

AUTO, COOL, DRY, and FAN. The mode 

indicator light illuminates under the 

selected mode settings Fig.3.

MODE select button

1

         Used to adjust (increasing/decreasing) 

O

O

         temperature settings(2 F/1 C increments)

O

O

O

O

         in a range of (62 F)17 C to (88 F)30 C or

         the TIMER setting in a range of 0~24hrs.

         

          

          

      

        

6

 UP(     ) and DOWN(    ) button

    

   

NOTE:

 The control is capable of displaying 

    temperature in degrees Fahrenheit or degrees  

   Celsius. To convert from one to the other, press 

   and hold the Up and Down buttons at the same 

    time, for 3 seconds.

3

Used to initiate the AUTO ON start time and

AUTO OFF stop time program, in conjunction

with the      and      buttons.

TIMER button

4

Used to initiate the SLEEP operation.

SLEEP button

6

2

         Power switch on/off.

POWER button

AUTO

COOL

DRY

FAN

MODE

SLEEP

FAN

HI

MED

LOW

TIMER ON

TIMER OFF

F

C

5

FAN button

7

O

 Shows the set temperature in    C

O

 "  F" and the Auto-timer settings.  

 While in DRY or FAN modes, it displays 

 the room temperature.

 

"

" or

LED Display

SWING

Remote signal receptor

8

Controls the fan speed. Each time the fan button

is pressed, a different fan speed is selected in a

sequence as follows: LOW, MED, HI and AUTO. 

When AUTO mode is selected, all of the fan

indicator lights turn off.

Error codes and protection code:

E1-  

Room temperature sensor error- 

        Unplug the unit and plug it back in. 

        If error repeats, call for service.

E2-  

Evaporator temperature sensor error- 

        Unplug the unit and plug it back in. 

        If error repeats, call for service.

E4-  Display panel communication

 error- 

        Unplug the unit and plug it back in. 

        If error repeats, call for service.

P1-  

Bottom  tray is full

 

- Connect the 

        drain hose and drain the collected 

        water away. If error repeats, call 

        for service.

Содержание Comfort-Aire PS-101A

Страница 1: ...h Ave Jackson MI 49203 517 787 2100 www heatcontroller com INSTALLATION OPERATION MAINTENANCE MANUAL Portable Room Air Conditioner PS 81A PS 101A PS 121A French version of this manual is available on...

Страница 2: ...g 15 AIR CONDITIONER FEATURES CARE AND MAINTENANCE TROUBLESHOOTING TIPS OPERATING INSTRUCTIONS INSTALLATION INSTRUCTIONS IDENTIFICATION OF PARTS SAFETY PRECAUTIONS Safety rules 3 Operating conditions...

Страница 3: ...r to avoid electrical shock Do not remove any cover panels Never use this appliance if it is not working properly or if it has been dropped or damaged Never use the plug to start and stop the unit Alw...

Страница 4: ...nces vapors in the vicinity of this or any other appliance To avoid fire hazard or electric shock do not use an extension cord or an adaptor plug Do not remove any prong from the power cord WARNING El...

Страница 5: ...rizontal Louver Blade swings automatically Casters Carrying Handles both sides 1 2 3 4 1 2 3 4 Fig 1 Fig 2 Rear 9 6 7 8 10 11 6 7 8 9 10 11 Upper Air Filter Behind the grille Air Outlet Power cord out...

Страница 6: ...sius To convert from one to the other press and hold the Up and Down buttons at the same time for 3 seconds 3 Used to initiate the AUTO ON start time and AUTO OFF stop time program in conjunction with...

Страница 7: ...tes It indicates that the Auto Start program is initiated Press or hold the UP or DOWN buttons to change the time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The con...

Страница 8: ...fully Use the SWING button on the remote controller to stop the louver at a desired angle If the louver is placed in a position which would affect the cooling process of the air conditioner it will au...

Страница 9: ...place any obstacles around the air inlet or outlet of the unit Allow 1ft 3ft 30cm to 100cm of space from the wall with for efficient air conditioning Fig 5 Your window slider kit has been designed to...

Страница 10: ...h of window shorten the adjustable window kit if the width of window is less than 26 5 67 5 cm Open the window sash and place the window slider kit on the window stool Fig 9 3 Cut the foam seal adhesi...

Страница 11: ...the adjustable window kit if the width of window is less than 26 5 67 5 cm Open the window sash and place the window slider kit on the window stool See Fig 13 3 Cut the foam seal adhesive type to the...

Страница 12: ...pages for window kit installation 2 Insert the hook of the Exhaust hose into the hole seat of the air outlet and slide down the Exhaust hose along the arrow direction See Fig 17 for installation IMPOR...

Страница 13: ...t floor Please refer to Fig 18 19 When the water level of the bottom tray reaches a predetermined level Carefully move the unit near a drain location remove the bottom drain plug and let the water dra...

Страница 14: ...ce Installation Insert the upper air filter from upward after cleaning attach the lower air filter on the air inlet grille then reinstall the grille by using the screw 2 Unit cabinet Use a lint free d...

Страница 15: ...doors in the room are not closed There are heat sources inside the room Exhaust air duct is not connected or blocked Temperature setting is too high Air filter is blocked by dust 2 Not cool enough Pl...

Страница 16: ...04 2009 3 2013...

Отзывы: